Door Switch
CHECK FUNCTION
CONSULT
Select “DOOR SW-DR”, “DOOR SW-AS”, “DOOR SW-RL” or “DOOR SW-RR” in “Data Monitor” mode of “BCM(DOOR LOCK)”.
Check that the function operates normally according to the following conditions:
| Monitor Item | Condition | Status | |
|---|---|---|---|
| DOOR SW-DR | Front door LH | Open | On |
| Closed | Off | ||
| DOOR SW-AS | Front door RH | Open | On |
| Closed | Off | ||
| DOOR SW-RL | Rear door LH | Open | On |
| Closed | Off | ||
| DOOR SW-RR | Rear door RH | Open | On |
| Closed | Off | ||
Is the inspection result normal?
YES>>Door switch is OK.
NO>>Refer to Diagnosis Procedure.
CHECK DOOR SWITCH INPUT SIGNAL
Ignition switch OFF.
Disconnect door switch connector.
Check signal between door switch harness connector and ground using oscilloscope.
(+) (–) Signal
(Reference value)Door switch Connector Terminal Front LH B8 3 Ground 7.0 - 8.0 V
Front RH B108 Rear LH B18 Rear RH B116
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK DOOR SWITCH CIRCUIT
Disconnect BCM connector.
Check continuity between door switch harness connector and BCM harness connector.
Door switch BCM Continuity Connector Terminal Connector Terminal Front LH B8 3 M20 96 Yes Front RH B108 94 Rear LH B18 82 Rear RH B116 93 Check continuity between door switch harness connector and ground.
Door switch Ground Continuity Connector Terminal Front LH B8 3 No Front RH B108 Rear LH B18 Rear RH B116
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK DOOR SWITCH
Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Replace malfunctioning door switch. Refer to Removal and Installation.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
>>Inspection End.
CHECK DOOR SWITCH
Ignition switch OFF.
Disconnect door switch connector.
Check continuity between door switch terminals.
Door switch Condition Continuity Terminal 3 Ground contact is part of the switch. Door switch Pressed No Released Yes
Is the inspection result normal?
YES>>Inspection End.
NO>>Replace malfunctioning door switch. Refer to Removal and Installation.