Back Door Request Switch
CHECK FUNCTION
CONSULT
Select “REQ SW-BD/TR” in “Data Monitor” mode of “BCM(INTELLIGENT KEY)”.
Check that the function operates normally according to the following conditions:
| Monitor Item | Condition | Status | |
|---|---|---|---|
| REQ SW-BD/TR | Back door request switch | Pressed | On |
| Released | Off | ||
Is the inspection result normal?
YES>>Back door request switch is OK.
NO>>Refer to Diagnosis Procedure.
CHECK BACK DOOR REQUEST SWITCH INPUT SIGNAL
Ignition switch OFF.
Disconnect back door opener switch connector.
Check voltage between back door opener switch harness connector and ground.
(+) (–) Voltage
(Approx.)Back door opener switch Connector Terminal D559 4 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK BACK DOOR REQUEST SWITCH CIRCUIT
Disconnect BCM connector.
Check continuity between BCM harness connector and back door opener switch harness connector.
BCM Back door opener switch Continuity Connector Terminal Connector Terminal M20 83 D559 4 Yes Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M20 83 No
Is the inspection result normal?
YES>>Replace BCM. Refer to Removal and Installation.
NO>>Repair or replace harness.
CHECK BACK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between back door opener switch harness connector and ground.
| Back door opener switch | Ground | Continuity | |
| Connector | Terminal | ||
| D559 | 3 | Yes | |
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace harness.
CHECK BACK DOOR REQUEST SWITCH
Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Replace back door opener switch. Refer to Removal and Installation.
CHECK INTERMITTENT INCIDENT
Refer to Intermittent Incident.
>>Inspection End.
CHECK BACK DOOR REQUEST SWITCH
Ignition switch OFF.
Disconnect back door opener switch connector.
Check continuity between back door opener switch terminals.
Back door opener switch Condition Continuity Terminal 3 4 Back door request switch Pressed Yes Released No
Is the inspection result normal?
YES>>Inspection End.