Door Lock Actuator. Front Lh
CHECK FUNCTION
CONSULT
Select “DOOR LOCK” in “Active Test” mode of “BCM(DOOR LOCK)”.
Select “ALL LOCK” or “ALL UNLK” to check that it works normally.
Is the inspection result normal?
YES>>Door lock actuator is OK.
NO>>Refer to Diagnosis Procedure.
CHECK DOOR LOCK ACTUATOR INPUT SIGNAL
Ignition switch OFF.
Disconnect front door lock assembly LH connector.
Check voltage between front door lock assembly LH harness connector and ground.
| (+) | (–) | Condition | Voltage (Approx.) | ||
|---|---|---|---|---|---|
| Front door lock assembly LH | |||||
| Connector | Terminal | ||||
| D14 | 1 | Ground | Door lock and unlock switch | Lock | Battery voltage |
| 2 | Unlock | ||||
Is the inspection result normal?
YES>>Replace front door lock assembly LH. Refer to Removal and Installation.
NO>>GO TO 2.
CHECK DOOR LOCK ACTUATOR CIRCUIT
Disconnect BCM and all door lock actuators.
Check continuity between BCM harness connector and front door lock assembly LH harness connector.
BCM Front door lock assembly LH Continuity Connector Terminal Connector Terminal M81 135 D14 1 Yes 137 2 Check continuity between BCM harness connector and ground.
BCM Ground Continuity Connector Terminal M81 135 No 137
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace harness.
CHECK BCM OUTPUT SIGNAL
Connect BCM connector.
Check voltage between BCM harness connector and ground.
| (+) | (–) | Condition | Voltage (Approx.) | ||
|---|---|---|---|---|---|
| BCM | |||||
| Connector | Terminal | ||||
| M81 | 135 | Ground | Door lock and unlock switch | Lock | Battery voltage |
| 137 | Unlock | ||||
Is the inspection result normal?
YES>>Check for internal short of each door lock actuator.
NO>>Replace BCM. Refer to Removal and Installation.