HINT:
The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not determine whether a part is faulty based only on these reference values.
(a) Turn the ignition switch OFF.
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn on the Techstream.
(e) Select the following menu items: Chassis / EMPS / Data List.
(f) Read the Data List according to the Techstream display.
Chassis > EMPS > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Meter Vehicle Velocity |
Speedometer vehicle speed |
Min.: 0 km/h Max.: 300 km/h |
|
- |
Wheel Speed Right |
Right rear wheel rotation speed |
Min.: 0 km/h Max.: 255 km/h |
|
- |
Wheel Speed Left |
Left rear wheel rotation speed |
Min.: 0 km/h Max.: 255 km/h |
|
- |
Engine Revolution |
Engine speed |
Min.: 0 rpm Max.: 12,800 rpm |
No significant change |
Engine runs at constant speed |
Motor Actual Current |
Amount of current supplied to the motor |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort - Value increases when turning left and decreases when turning right |
Engine running and steering wheel turned |
Command Value Current |
Current required to the motor |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort - Value increases when turning left and decreases when turning right |
Engine running and steering wheel turned |
Steering Angle Velocity |
Steering angle speed |
Min.: -32,768 deg/s Max.: 32,767 deg/s |
Value changes in proportion to steering speed - Value increases when turning left and decreases when turning right |
Engine running and steering wheel turned |
Thermistor Temperature |
ECU board temperature |
Min.: -50.0 °C Max.: 150 °C |
-50°C à 150 °C |
- |
IG Power Supply |
IG power supply voltage |
Min.: 0.0000 V Max.: 20.1531 V |
8 à 16 V |
Ignition Switch in ON position |
Steering Angle Sens Sig |
Steering Angle Sensor Signal Status |
OK or NG(1) or NG(2) or NG(3) |
OK: Steering angle sensor signal received NG (1): Learning is not completed NG (2): Steering angle sensor abnormal NG (3): Communication error |
- |
Steering Wheel Torque |
Steering wheel torque |
Min.: -7.0 N·m Max.: 7 N·m |
Value changes in proportion to steering effort - Value increases when turning left and decreases when turning right |
Engine running and steering wheel turned |
Motor Rotation Angle |
Motor rotation angle |
Min.: 0.000 deg. Max.: 360.000 deg. |
Motor rotation angle varies from 0 to 360° during steering operation |
Engine running and steering wheel turned |
Command Val Current 2 |
Current required to the motor |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor Voltage |
Motor power supply voltage |
Min.: 0.000 V Max.: 98.000 V |
|
- |
TRQ1 Zero Point Value |
Torque sensor 1 zero point value |
Min.: 0.0000 V Max.: 4.9725 V |
2,3 à 2,7 V |
Engine running and steering wheel not turned (no load) |
TRQ2 Zero Point Value |
Torque sensor 2 zero point value |
Min.: 0.0000 V Max.: 4.9725 V |
2,3 à 2,7 V |
Engine running and steering wheel not turned (no load) |
IG ON/OFF Times |
Number of times the ignition switch has been turned ON/OFF since the last DTC detection |
Min.: 0 times Max.: 65,535 times |
- |
- |
Motor Overheat Record |
Continuous Motor Overheat Prevention Control Record |
Unrec or Rec |
Unrec |
Unrec: Not recorded Rec: Recorded The steering assist amount may decrease to prevent the motor and ECUs from overheating if the steering wheel is continuously operated while the vehicle is stopped or driven at low speed, or if the steering wheel is held at the lock position for a long time. |
Motor Low Power Record |
PIG Power Supply Voltage Drop Record |
Unrec or Rec |
Unrec |
Unrec: Not recorded Rec: Recorded If the PIG power supply voltage temporarily drops, the steering assist amount will be reduced. |
Eng Rev Inter Record |
Engine Speed Signal Interruption Record |
Unrec or Rec |
Unrec |
Unrec: Not recorded Rec: Recorded |
Str Angle Inter Record |
Steering Angle Sensor Signal Interruption Occurrence Screen Record |
Unrec or Rec |
Unrec |
Unrec: Not recorded Rec: Recorded |
Spd Sig Invalid Record |
Invalid Vehicle Speed Signal Record |
Unrec or Rec |
Unrec |
Unrec: Not recorded Rec: Recorded |
Battery Voltage Lo Record |
Battery Voltage Drop History |
Min.: 0 times Max.: 65,535 times |
0 to 65,535 times |
- |
Battery Control Count (Body ECU) |
Battery Charge Control Usage Count |
Min.: 0 times Max.: 65,535 times |
- |
- |
PS Assist Signal |
Power steering assist signal recording status |
OFF or ON |
OFF: Ignition switch in ON position ON: Engine running |
- |
Motor Actual Current 2 |
Amount of current supplied to the motor |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Stop&Start Ctrl Mode |
Stop & start control mode recording status |
IG, Run, Stopreq, Stop, Restart |
IG: Ignition switch in ON position (before engine start) Run: Engine running Stopreq: Engine stop request Stop: Engine stopped Restart: Engine restart |
- |
Motor Overheat Limit Cnt(Normal) |
Number of times the assist limit was applied based on the estimated temperature of the electric motor coil and the heat-generating components of the EPS ECU assembly |
Min.: 0 times Max.: 255 times |
- |
- |
Assist Limit Cnt(Power Voltage Low) |
Number of times the assist limit was applied due to a battery voltage drop to 9 V or below |
Min.: 0 times Max.: 255 times |
- |
- |
Power Vol Low Prevention Limit Cnt |
Number of times the assist limit was applied due to a battery voltage drop to 9.7 V or below |
Min.: 0 times Max.: 255 times |
- |
- |
Eng Stall/Ready OFF Cnt |
Number of times the assist limit was applied after the engine stalled and the ignition switch was turned OFF |
Min.: 0 times Max.: 255 times |
- |
- |
Motor Overheat Limit Cnt(Motor Overload) |
Number of times the assist limit was applied to prevent system overheating when the electric motor was overloaded because the steering wheel was held at full lock or one of the tires hit a curb |
Min.: 0 times Max.: 255 times |
- |
- |
Assist Limit Cnt(Vehicle Spd Sig Malf) |
Number of times the assist power was adjusted to a level suitable for high-speed driving when high speed was detected due to an abnormal vehicle speed signal |
Min.: 0 times Max.: 255 times |
- |
- |
Assist Limit Record 1 |
Assist limit information used in the past or currently in use (most recent history) |
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, DC-DC Malf, Vhcl Spd Sig Malf, Batt Vol Keep |
- |
- |
Record 1 Key Cycle |
Number of times the ignition switch was turned ON before assist limit Record 1 was stored |
Min.: 0 times Max.: 65,535 times |
- |
- |
Record 1 Key Cycle Elapsed Time |
Elapsed time after the ignition switch was turned ON before assist limit Record 1 was stored |
Min.: 0.0 s Max.: 53,687,091.0 s |
- |
- |
Record 1 Power Source |
Power source operating status when assist limit Record 1 was stored |
No Data, Running, Stop |
- |
- |
Assist Limit Record 2 |
Assist limit information used in the past (second most recent history) |
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, DC-DC Malf, Vhcl Spd Sig Malf, Batt Vol Keep |
- |
- |
Record 2 Key Cycle |
Number of times the ignition switch was turned ON after Record 2 was stored and before assist limit Record 1 was stored |
Min.: 0 times Max.: 65,535 times |
- |
- |
Record 2 Key Cycle Elapsed Time |
Elapsed time after the ignition switch was turned ON before assist limit Record 2 was stored |
Min.: 0.0 s Max.: 53,687,091.0 s |
- |
- |
Record 2 Power Source |
Power source operating status when assist limit Record 2 was stored |
No Data, Running, Stop |
- |
- |
Assist Limit Record 3 |
Assist limit information used in the past (third most recent history) |
Unrec, Mtr Overheat, Pow Vol Low, Pow Vol Low Prevent, Eng Stall, Ready OFF, Mtr Overload, DC-DC Malf, Vhcl Spd Sig Malf, Batt Vol Keep |
- |
- |
Record 3 Key Cycle |
Number of times the ignition switch was turned ON after Record 3 was stored and before assist limit Record 2 was stored |
Min.: 0 times Max.: 65,535 times |
- |
- |
Record 3 Key Cycle Elapsed Time |
Elapsed time after the ignition switch was turned ON before assist limit Record 3 was stored |
Min.: 0.0 s Max.: 53,687,091.0 s |
- |
- |
Record 3 Power Source |
Power source operating status when assist limit Record 3 was stored |
No Data, Running, Stop |
- |
- |
Steering Angle |
Steering angle |
Min.: -3,072.0 deg. Max.: 3,070.5 deg. |
- |
- |
Torque Sensor 1 Output |
Torque sensor 1 output value |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Torque Sensor 2 Output |
Torque sensor 2 output value |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Torque Sensor 1 Power Supply |
Torque sensor 1 power supply voltage |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Torque Sensor 2 Power Supply |
Torque sensor 2 power supply voltage |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Rotation Angle Sensor Output 1 |
Rotation angle sensor output voltage Vx1 |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Rotation Angle Sensor Output 2 |
Rotation angle sensor output voltage Vx2 |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Rotation Angle Sensor Output 3 |
Rotation Angle Sensor Output Voltage Vy1 |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Rotation Angle Sensor Output 4 |
Rotation Angle Sensor Output Voltage Vy2 |
Min.: 0.0000 V Max.: 4.9725 V |
- |
- |
Motor 1 Terminal Current (U) |
Motor 1 Terminal Current (U Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 1 Terminal Current (V) |
Motor 1 Terminal Current (V Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 1 Terminal Current (W) |
Motor 1 Terminal Current (W Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 2 Terminal Current (U) |
Motor 2 Terminal Current (U Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 2 Terminal Current (V) |
Motor 2 Terminal Current (V Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 2 Terminal Current (W) |
Motor 2 Terminal Current (W Phase) |
Min.: -327.68 A Max.: 327.67 A |
Value changes in proportion to steering effort |
Engine running and steering wheel turned |
Motor 1 U Phase Duty |
Motor 1 U Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 1 V Phase Duty |
Motor 1 V Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 1 W Phase Duty |
Motor 1 W Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 2 U Phase Duty |
Motor 2 U Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 2 V Phase Duty |
Motor 2 V Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 2 W Phase Duty |
Motor 2 W Phase Duty |
Min.: 0.00 % Max.: 100.00 % |
- |
- |
Motor 1 Terminal Voltage (U) |
Motor 1 Terminal Voltage (U Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 1 Terminal Voltage (V) |
Motor 1 Terminal Voltage (V Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 1 Terminal Voltage (W) |
Motor 1 Terminal Voltage (W Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 2 Terminal Voltage (U) |
Motor 2 Terminal Voltage (U Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 2 Terminal Voltage (V) |
Motor 2 Terminal Voltage (V Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 2 Terminal Voltage (W) |
Motor 2 Terminal Voltage (W Phase) |
Min.: 0.000 V Max.: 98.000 V |
Value varies in the range of 4 to 35 V |
Engine running and steering wheel turned |
Motor 1 PIG Power Supply |
Power supply voltage for driving Motor 1 |
Min.: 0.0000 V Max.: 20.1531 V |
9 à 16 V |
Engine running and steering wheel turned |
Motor 2 PIG Power Supply |
Power supply voltage for driving Motor 2 |
Min.: 0.0000 V Max.: 20.1531 V |
9 à 16 V |
Engine running and steering wheel turned |
The Number of DTCs |
Number of DTCs detected when freeze frame data was stored |
Min.: 0 Max.: 255 |
0 à 255 |
- |
HINT:
- When the vehicle is stationary or moving very slowly, if the steering wheel is turned repeatedly or held at full lock for an extended period, the steering assist amount will be reduced to prevent overheating of the motor and ECU. In this case, leave the engine running and do not turn the steering wheel for about 10 minutes to allow steering assist to recover.
- When the battery is not sufficiently charged or the voltage temporarily drops, the steering assist amount is reduced and the EPS warning light comes on. In this case, the steering assist force returns to normal when the battery voltage is restored.