Heater / Air Conditioning

Backup Power Supply Circuit

~1min read

DESCRIPTION

The backup power source circuit for the air conditioning amplifier assembly is shown in the diagram below. Power is supplied even when the ignition switch is OFF. This power supply is used to retain diagnostic trouble codes, etc.

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

Check the fuses for the circuits related to this system before performing the following procedure.

PROCEDURE

  1. CHECK WIRE HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - POWER SOURCE)

(a) Disconnect the connector from the air conditioning amplifier assembly.

*a

Front view of wire harness side connector

(to A/C amplifier assembly)

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

F139-1 (B) - Body ground

Always

11 à 14 V

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. CHECK WIRE HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BODY GROUND)

(a) Disconnect the F139 connector from the air conditioning amplifier assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

F139-4 (GND) - Body ground

Always

Below 1 Ω

OK

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR