Heater / Air Conditioning

System Description

~11min read

SYSTEM DESCRIPTION

GENERAL

The air conditioning system is equipped with the following controls:

Control

General Description

Neural Network Control

This control performs complex control by artificially simulating the information processing method of the nervous system of living organisms, in order to establish a complex input/output relationship similar to that of the human brain.

Discharge Air Temperature Control

Based on the temperature set with the temperature selector, the neural network control calculates the discharge air temperature from the input signals sent by various sensors.

Independent Left and Right Control

The temperature settings for the driver and front passenger are controlled independently, so that the interior temperature can differ between the left and right sides of the cabin. This provides air conditioning suited to each occupant's preference.

Blower Control

Controls the blower motor based on the airflow calculated by the neural network control, using input signals sent by various sensors.

Air Outlet Control

Automatically switches the air outlets according to the air outlet mode calculated by the neural network control.

Based on engine coolant temperature, outside air temperature, amount of sunlight, required blower airflow, discharge air temperature and vehicle speed, this control automatically switches the blower outlet to floor/defrost mode to prevent fogging of the windows when the outside air temperature is low.

Air Inlet Control

Automatically controls the air inlet control damper to help achieve the calculated required discharge air temperature.

Drives the air inlet control servo motor according to the operation of the air inlet control switch, and moves the dampers to the Recirculated Air/Fresh Air position.

Variable Capacity Compressor Control

Controls the compressor assembly with pulley to engage or disengage it, and adjusts the discharge capacity based on signals sent by various sensors.

Defogger Control

The defogger control logic is used to improve defogger performance.

PTC Heater Control

When the engine is running and the blower motor assembly with fan is on, the air conditioning amplifier assembly turns on the quick heater assembly if the following conditions are met:

  • The engine coolant temperature is below the specified temperature.
  • The outside air temperature is below the specified temperature.
  • The temporary opening angle of the air mix damper is greater than the specified value (MAX HOT).

ECO Mode Control

When the air conditioning control assembly (ECO mode switch) is turned on, the air conditioning amplifier assembly limits the air conditioning performance.

Parked Car Outside Air Control

Automatically switches to outside air mode when the vehicle is parked. This makes it easier to ventilate the parked vehicle and introduces outside air into the air conditioning unit assembly.

Diagnosis

A diagnostic trouble code (DTC) is stored in memory when the air conditioning amplifier assembly detects a malfunction in the air conditioning system.

NEURAL NETWORK CONTROL

  • In previous automatic air conditioning systems, the air conditioning amplifier assembly determined the outlet air temperature and the required blower air volume using a calculation formula based on information from the sensors.

    However, because human perception is complex, a given temperature may feel different depending on the environment the occupant is in. For example, a given level of sunlight may feel pleasantly warm in cold weather, or very uncomfortable in hot weather. For this reason, a neural network has been adopted in the automatic air conditioning system to achieve more precise control. Using this technology, data collected under various weather conditions is stored in the air conditioning amplifier assembly. The amplifier can therefore control the system to provide improved air conditioning comfort.

  • The neural network control consists of neurons in the input, intermediate and output layers. The input layer neurons process the data received for outside air temperature, sunload and cabin temperature based on the data supplied by the switches and sensors, then transmit it to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the connections between neurons. The output layer neurons then calculate their sum as the outlet air temperature, solar correction, target airflow and required outlet mode control volume. The air conditioning amplifier assembly accordingly controls the servo motors and the blower motor according to the control volumes calculated by the neural network control.

MODE POSITION AND DAMPER OPERATION

Mode position and damper operation

*A

for manual air conditioning system

*B

for automatic air conditioning system

*1

Driver side air mix control damper

*2

Front passenger side air mix control damper

*3

Driver side defroster

*4

Front defroster

*5

Front passenger side defroster

*6

Air inlet control damper (lower side)

*7

Air inlet control damper (upper side)

*8

Air purification filter

*9

Blower motor sub-assembly with fan

*10

No. 1 cooler evaporator sub-assembly

*11

Air mix control damper

*12

Heater unit sub-assembly

*13

Mode switching damper

*14

Driver side floor register

*15

Front passenger side floor register

*16

Driver side register

*17

Center register

*18

Front passenger side register

*19

Quick heating assembly

*20

Rear left floor register

*21

Rear right floor register

-

-

*a

View of diagram from [A]

*b

View [A]

*c

Recirculated air

*d

Outside air

Main Damper Functions

Control damper

Operation position

Damper position

Operation

Air inlet control damper

FRESH

A1, B1

Allows outside air to enter.

RECIRCULATION

A2, B2

Recirculates inside air.

Air mix control damper

Temperature setting: 16 °C to 30 °C

C1 - C2

Varies the mix ratio of outside air and recirculated air on the driver side to continuously control the temperature between HI and LO.

D2 - D1

Varies the mix ratio of outside air and recirculated air on the front passenger side to continuously control the temperature between HI and LO.

Air outlet damper

DEF

F, H, K

Defrosts the windshield using the center defroster, side defrosters and side registers.

FOOT/DEF

F, H, J à K

Defrosts the windshield via the center defroster, side defrosters and side registers, while blowing air from the front and rear floor register ducts.

FOOT

E, (E à F)*, H, J

Air blows from the front and rear floor register ducts and the side registers. Air also blows slightly from the center defroster and side defrosters.

B/L

E, G à I, J à K

Air blows from the center registers, side registers and front and rear floor register ducts.

FACE

E, G, K

Air blows from the center registers and side registers.

AIR OUTLETS AND AIRFLOW VOLUME

The size of each circle ○ indicates the airflow volume ratio.

(a) Air outlets and airflow.

Mode

FACE

FOOT

DEF

Center

Side

Front

Rear

Center

Side

A

B

C

D

D

E

FACE

B/L

FOOT

FOOT/DEF

DEF

OUTSIDE AIR INTRODUCTION DURING PARKING CONTROL

When 60 seconds have elapsed after the ignition switch is turned to OFF, the air conditioning amplifier assembly uses control logic that automatically switches the air inlet to "FRESH" mode to purge unwanted odors from the air conditioning unit.

This control logic reduces unwanted odors when the air conditioning system is started.

COMPRESSOR WITH PULLEY

(a) General:

(1) The compressor is a continuously variable capacity type, and its capacity changes according to the cooling load of the air conditioning system.

*1

Shoe

*2

Crank chamber

*3

Shaft

*4

Swash plate

*5

Piston

*6

Cylinder

*7

Control valve

-

-

(b) Control valve operation:

(1) The crank chamber is connected to the suction passage. A control valve is located between the suction passage (low pressure) and the discharge passage (high pressure).

(2) The control valve operates under duty cycle control based on signals from the air conditioning amplifier assembly.

*1

Suction passage

*2

Crank chamber

*3

Piston

*4

Discharge passage

*5

Control valve

*6

Air Conditioning Amplifier Assembly

(3) When the control solenoid valve is closed (the solenoid coil is energized), a pressure differential is created and the pressure in the suction chamber decreases. As a result, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the swash plate. Consequently, the piston stroke increases, as does the discharge capacity.

*1

Suction passage

*2

Crank chamber

*3

Piston

*4

Discharge passage

*5

Control valve

*6

Air Conditioning Amplifier Assembly

*a

Suction chamber pressure + Spring force

*b

Piston stroke: Large

(4) When the control solenoid valve is open (the solenoid coil is not energized), the pressure differential disappears. As a result, the pressure applied to the left side of the piston becomes equal to the pressure applied to the right side of the piston. The spring then extends and removes the tilt of the swash plate. Consequently, the piston stroke is limited and the discharge capacity decreases.

*1

Suction passage

*2

Crank chamber

*3

Piston

*4

Discharge passage

*5

Control valve

*6

Air Conditioning Amplifier Assembly

*a

Suction chamber pressure + Spring force

*b

Piston stroke: Small

NO. 1 COOLER THERMISTOR (EVAPORATOR TEMPERATURE SENSOR)

The No. 1 cooler thermistor (evaporator temperature sensor) detects the temperature of the cold air that has passed through the evaporator as changes in resistance, and sends it to the air conditioning amplifier assembly.

BLOWER MOTOR SUB-ASSEMBLY WITH FAN

The blower motor has a built-in blower controller and is controlled by a service control performed by the air conditioning amplifier assembly.

SERVO MOTOR

A pulse-type servo motor consists of a circuit board and a servo motor. The circuit board has three contact points and can output two ON-OFF signals to the air conditioning amplifier assembly based on the difference in pulse phases. The bus connector can detect the damper position and direction of movement using these signals.

COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)

The cooler thermistor (room temperature sensor) detects the cabin temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.

THERMISTOR ASSEMBLY

The thermistor assembly detects the outside air temperature based on changes in the resistance of its built-in thermistor and sends a signal to the air conditioning amplifier assembly.

AUTOMATIC LIGHT CONTROL SENSOR

The auto light control sensor detects changes in the degree of sunlight (as changes in the current flowing through the built-in photodiode) and sends these sunlight level signals to the air conditioning amplifier assembly.

AIR CONDITIONING PRESSURE SENSOR

The air conditioning pressure sensor detects the refrigerant pressure and sends it to the air conditioning amplifier assembly as voltage changes.

QUICK HEATER ASSEMBLY

(a) General

(1) The quick heater assembly is located on the heater core in the air conditioning radiator assembly.

(2) The quick heater assembly consists of a PTC heater element, aluminum fins and brass plates. When current is applied to the PTC heater element, it generates heat that warms the air passing through the unit.

*1

Quick heating assembly

*2

Brass plate

*3

PTC heater element

*4

Aluminum fin

(b) Quick heater assembly operating conditions

(1) The quick heater assembly is turned on and off by the air conditioning assembly based on the engine coolant temperature, outside air temperature, temperature setting and electrical load (generator power ratio).