Cabin Temperature Sensor Circuit (B1411)
DESCRIPTION
The cooler thermistor (cabin temperature sensor) is mounted on the instrument panel to detect the cabin temperature, which is used to control the air conditioning system. The resistance of the cooler thermistor (cabin temperature sensor) changes according to the cabin temperature. Resistance increases as temperature decreases. Resistance decreases as temperature increases.
The air conditioning amplifier assembly applies a voltage (5 V) to the cooler thermistor (cabin temperature sensor) and detects the voltage change caused by the change in resistance of the cooler thermistor (cabin temperature sensor).
DTC No. | Detection Item | DTC Detection Condition | Suspected Area | Memory |
|---|---|---|---|---|
B1411 |
Cabin Temperature Sensor Circuit |
One of the following conditions is met
|
|
Stored (4 seconds minimum)* |
- *: The A/C amplifier assembly stores this DTC if the malfunction occurs within the time period shown in parentheses.
HINT:
If the cabin temperature is approximately -186 °C or lower, DTC B1411 may be output even if the system is normal.
DTC Detection ConditionsVehicle Operating Conditions |
|||
|---|---|---|---|
Sequence 1 | Sequence 2 |
||
Diagnostic Condition |
Ignition Switch in ON position |
○ |
○ |
Malfunction Status |
Open in Cooler Thermistor (Room Temperature Sensor) Circuit |
○ |
- |
Short in Cooler Thermistor (Room Temperature Sensor) Circuit |
- |
○ |
|
Detection Duration |
4 seconds minimum |
4 seconds minimum |
|
Number of Trips |
1 trip(s) |
1 trip(s) |
|
HINT:
The DTC is output when the conditions for any one of the sequences in the table above are met.
WIRING DIAGRAM
PROCEDURE
CHECK VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Room Temperature Sensor |
Cooler Thermistor (Room Temperature Sensor) |
Min.: -6,50 °C Max.: 57 °C |
Actual Room Temperature Displayed |
- |
Room Temperature Sensor
OK:
The displayed value is within the specifications in the normal condition column.
Result:
| Result | Proceed to |
|---|---|
NG |
A |
OK (when troubleshooting is performed based on the Symptom Chart) |
B |
OK (when troubleshooting is performed using DTC) |
C |
| B | GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE |
| C | GO TO STEP 4 |
|
INSPECT COOLER THERMISTOR (CABIN TEMPERATURE SENSOR)
(a) Remove the cooler thermistor (cabin temperature sensor).
Click here![]()
(b) Inspect the cooler thermistor (cabin temperature sensor).
Click here![]()
| NG | REPLACE COOLER THERMISTOR (CABIN TEMP. SENSOR) |
|
INSPECT WIRE HARNESS AND CONNECTOR (COOLER THERMISTOR (CABIN TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
F138-14 (TR) - F60-1 |
Always |
Below 1 Ω |
F138-1 (SG-1) - F60-2 |
Always |
Below 1 Ω |
F138-14 (TR) or F60-1 - Body ground |
Always |
10 kΩ minimum |
F138-1 (SG-1) or F60-2 - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK WHETHER DTCs ARE OUTPUT
(a) Clear the DTCs.
Click here![]()
(b) Check DTCs.
Click here![]()
Result:
Result | Proceed to |
|---|---|
No DTCs are output |
A |
DTCs are output |
B |
| A | USE SIMULATION METHOD TO CHECK |
| B | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |