Heater / Air Conditioning

Refrigerant Shortage (B14B8)

~7min read

DESCRIPTION

This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.

The A/C amplifier assembly receives, among other things, the ambient temperature signal and the refrigerant pressure signal from various sensors.

Based on these signals, the A/C amplifier assembly detects the amount of refrigerant.

The A/C switch indicator light goes off and the air conditioning system stops if the amount of refrigerant is insufficient.

DTC No.

Detection Item

DTC Detection Condition

Suspected Area

Memory

B14B8

Refrigerant Shortage

When the following condition is detected using the refrigerant shortage check during normal operation:

Refrigerant quantity is insufficient

  • Refrigerant Line
  • Chiller Expansion Valve
  • Air Conditioning Amplifier Assembly

Stored

(15 min. minimum)*

  • *: The A/C amplifier assembly stores this DTC if the malfunction occurs within the time period shown in parentheses.

WIRING DIAGRAM

PROCEDURE

  1. CHECK REFRIGERANT PRESSURE

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.

(e) Read the Data List by following the instructions on the Techstream.

Body Electrical > Air Conditioner > Data List

Tester display

Item

Range

Normal Condition

Diagnostic Note

Regulator Pressure Sensor

Air Conditioning Pressure Sensor

Min.: -456.6 kPaG

Max.: 3,294.3 kPaG

Actual Refrigerant Pressure Displayed

-

Body Electrical > Air Conditioner > Data List

Regulator Pressure Sensor

(f) Connect a manifold gauge set.

Click here

(g) Read the manifold gauge pressure when the following conditions are met.

(1) Prepare the vehicle as indicated in the table below.

Measurement condition:

Item

Condition

Vehicle Doors

Fully open

Temperature control setting

MAX COLD

Blower speed

HI

A/C switch

ON

Recirculation/Fresh Air Switch

RECIRCULATION

Indoor Temperature

25 à 35 °C

Standard Pressure:

Low Pressure Side

150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)

High Pressure Side

1,370 to 1,570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)

(h) Compare the values displayed on the Data List and on the pressure gauge.

OK:

The values displayed on the Data List and on the pressure gauge match.

OK

CHECK REFRIGERANT PRESSURE

NG
  1. CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)

(a) Disconnect the air conditioning pressure sensor connector.

*a

Front view of wire harness side connector

(to Air Conditioning Pressure Sensor)

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Ignition switch position

Specified Condition

A52-3 (+) - A52-1 (-)

Ignition Switch in ON position

4,75 à 5,25 V

NG

GO TO STEP 7

OK
  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)

(a) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

A52-1 (-) - Body ground

Always

Below 1 Ω

NG

GO TO STEP 6

OK
  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)

(a) Disconnect the F138 connector from the air conditioner amplifier assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

A52-2 (PR) - F138-24 (PRE)

Always

Below 1 Ω

A52-2 (PR) or F138-24 (PRE) - Body ground

Always

10 kΩ minimum

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. CHECK AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)

(a) Measure the voltage under the following conditions.

Measurement condition:

Item

Condition

Vehicle Doors

Fully open

Temperature control setting

MAX COLD

Blower speed

HI

A/C switch

ON

Recirculation/Fresh Air Switch

RECIRCULATION

Indoor Temperature

25 à 35 °C

NOTICE:

  • If the high pressure side refrigerant pressure becomes extremely high during the check (voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe function activates.
  • The voltage must be measured for a certain period (approximately 10 minutes), as the malfunction may reoccur after some time.

HINT:

When the outside temperature is low (below -1.5 °C), the compressor stops due to the activation of the thermistor assembly and No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the check indoors in a warm environment.

(1) Measure the voltage according to the value(s) shown in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

F138-24 (PRE) - Body ground

Ignition Switch in ON position

(A/C switch: ON)

0,74 à 4,61 V

*a

Component with Wire Harness Connected

(A/C Amplifier Assembly)

(b) Connect the Techstream to the DLC3.

(c) Turn the ignition switch to ON.

(d) Turn on the Techstream.

(e) Select the following menu items: Body Electrical / Air Conditioner / Data List.

(f) Read the Data List by following the Techstream instructions.

Body Electrical > Air Conditioner > Data List

Tester display

Item

Range

Normal Condition

Diagnostic Note

Regulator Pressure Sensor

Air Conditioning Pressure Sensor

Min.: -456.6 kPaG

Max.: 3,294.3 kPaG

Actual Refrigerant Pressure Displayed

-

Body Electrical > Air Conditioner > Data List

Regulator Pressure Sensor

OK:

The voltage and the value displayed on the Data List change.

Result:

Result

Proceed to

OK

A

NG (voltage changes but the value displayed on the Data List does not change)

NG (voltage does not change)

B

A

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

B

REPLACE AIR CONDITIONING PRESSURE SENSOR

  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)

(a) Disconnect the F138 connector from the air conditioner amplifier assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

A52-1 (-) - F138-2 (SG-2)

Always

Below 1 Ω

A52-1 (-) or F138-2 (SG-2) - Body ground

Always

10 kΩ minimum

OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

  1. CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)

(a) Disconnect the F138 connector from the air conditioner amplifier assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

A52-3 (+) - F138-6 (S5-3)

Always

Below 1 Ω

A52-3 (+) or F138-6 (S5-3) - Body ground

Always

10 kΩ minimum

OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR