Refrigerant Shortage (B14B8)
DESCRIPTION
This DTC is stored if the amount of refrigerant in the air conditioning system is insufficient.
The A/C amplifier assembly receives, among other things, the ambient temperature signal and the refrigerant pressure signal from various sensors.
Based on these signals, the A/C amplifier assembly detects the amount of refrigerant.
The A/C switch indicator light goes off and the air conditioning system stops if the amount of refrigerant is insufficient.
DTC No. | Detection Item | DTC Detection Condition | Suspected Area | Memory |
|---|---|---|---|---|
B14B8 |
Refrigerant Shortage |
When the following condition is detected using the refrigerant shortage check during normal operation: Refrigerant quantity is insufficient |
|
Stored (15 min. minimum)* |
- *: The A/C amplifier assembly stores this DTC if the malfunction occurs within the time period shown in parentheses.
WIRING DIAGRAM
PROCEDURE
CHECK REFRIGERANT PRESSURE
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: -456.6 kPaG Max.: 3,294.3 kPaG |
Actual Refrigerant Pressure Displayed |
- |
Regulator Pressure Sensor
(f) Connect a manifold gauge set.
Click here![]()
(g) Read the manifold gauge pressure when the following conditions are met.
(1) Prepare the vehicle as indicated in the table below.
Measurement condition:Item | Condition |
|---|---|
Vehicle Doors |
Fully open |
Temperature control setting |
MAX COLD |
Blower speed |
HI |
A/C switch |
ON |
Recirculation/Fresh Air Switch |
RECIRCULATION |
Indoor Temperature |
25 à 35 °C |
Standard Pressure:
Low Pressure Side
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High Pressure Side
1,370 to 1,570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
(h) Compare the values displayed on the Data List and on the pressure gauge.
OK:
The values displayed on the Data List and on the pressure gauge match.
| OK | CHECK REFRIGERANT PRESSURE |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
(a) Disconnect the air conditioning pressure sensor connector. |
|
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
Tester Connection | Ignition switch position | Specified Condition |
|---|---|---|
A52-3 (+) - A52-1 (-) |
Ignition Switch in ON position |
4,75 à 5,25 V |
| NG | GO TO STEP 7 |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-1 (-) - Body ground |
Always |
Below 1 Ω |
| NG | GO TO STEP 6 |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-2 (PR) - F138-24 (PRE) |
Always |
Below 1 Ω |
A52-2 (PR) or F138-24 (PRE) - Body ground |
Always |
10 kΩ minimum |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
(a) Measure the voltage under the following conditions.
Measurement condition:Item | Condition |
|---|---|
Vehicle Doors |
Fully open |
Temperature control setting |
MAX COLD |
Blower speed |
HI |
A/C switch |
ON |
Recirculation/Fresh Air Switch |
RECIRCULATION |
Indoor Temperature |
25 à 35 °C |
NOTICE:
- If the high pressure side refrigerant pressure becomes extremely high during the check (voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe function activates.
- The voltage must be measured for a certain period (approximately 10 minutes), as the malfunction may reoccur after some time.
HINT:
When the outside temperature is low (below -1.5 °C), the compressor stops due to the activation of the thermistor assembly and No. 1 cooler thermistor to prevent the evaporator from freezing. In this case, perform the check indoors in a warm environment.
(1) Measure the voltage according to the value(s) shown in the table below. Standard voltage:
|
|
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn on the Techstream.
(e) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(f) Read the Data List by following the Techstream instructions.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: -456.6 kPaG Max.: 3,294.3 kPaG |
Actual Refrigerant Pressure Displayed |
- |
Regulator Pressure Sensor
OK:
The voltage and the value displayed on the Data List change.
Result:
Result | Proceed to |
|---|---|
OK |
A |
NG (voltage changes but the value displayed on the Data List does not change) |
|
NG (voltage does not change) |
B |
| A | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| B | REPLACE AIR CONDITIONING PRESSURE SENSOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-1 (-) - F138-2 (SG-2) |
Always |
Below 1 Ω |
A52-1 (-) or F138-2 (SG-2) - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-3 (+) - F138-6 (S5-3) |
Always |
Below 1 Ω |
A52-3 (+) or F138-6 (S5-3) - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |