Heater / Air Conditioning

Blower Motor Circuit

~4min read

DESCRIPTION

The blower motor with fan sub-assembly is operated by signals from the air conditioning amplifier assembly. The blower motor speed signals are transmitted according to changes in the duty cycle.

WIRING DIAGRAM

PRECAUTION / NOTICE / HINT

NOTICE:

Check the fuses for the circuits related to this system before performing the following procedure.

PROCEDURE

  1. PERFORM ACTIVE TEST USING TECHSTREAM

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Air Conditioner / Active Test.

(e) Perform the Active Test by following the Techstream instructions.

Body Electrical > Air Conditioner > Active Test

Tester display

Item

Control Range

Diagnostic Note

Blower Motor

Blower motor sub-assembly with fan

Min.: 0, Max.: 31

-

Body Electrical > Air Conditioner > Active Test

Blower Motor

Result:

Result

Proceed to

OK

A

NG (the blower motor with fan sub-assembly does not operate)

B

NG (the blower motor with fan sub-assembly operates but does not change speed)

C

A

GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE

C

GO TO STEP 6

B
  1. INSPECT WIRE HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BODY GROUND)

(a) Disconnect the A85 connector from the blower motor with fan sub-assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

A85-1 (GND) - Body ground

Always

Below 1 Ω

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT WIRE HARNESS AND CONNECTOR (BLOWER MOTOR WITH FAN SUB-ASSEMBLY - BATTERY)

(a) Measure the voltage according to the value(s) shown in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

A85-3 (+B) - Body ground

Always

11 à 14 V

*a

Front view of wire harness side connector

(to blower motor with fan sub-assembly)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT WIRE HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - BLOWER MOTOR WITH FAN SUB-ASSEMBLY)

(a) Disconnect the F139 connector from the air conditioning amplifier assembly.

(b) Measure the resistance according to the value(s) in the table below.

Standard resistance:

Tester Connection

Condition

Specified Condition

F139-6 (BLW) - A85-2 (SI)

Always

Below 1 Ω

F139-6 (BLW) or A85-2 (SI) - Body ground

Always

10 kΩ minimum

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

OK
  1. INSPECT BLOWER MOTOR WITH FAN SUB-ASSEMBLY

(a) Reconnect the A85 connector to the blower motor with fan sub-assembly.

(b) Measure the voltage according to the value(s) in the table below.

Standard voltage:

Tester Connection

Condition

Specified Condition

F139-6 (BLW) - Body ground

Always

4,75 à 5,25 V

*a

Front view of wire harness side connector

(to A/C amplifier assembly)

NG

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

OK
  1. CHECK AIR CONDITIONING AMPLIFIER ASSY

(a) Reconnect the F139 connector to the air conditioning amplifier assembly.

(b) Turn the ignition switch to ON.

(c) Set the blower switch to ON (LO).

(d) Connect an oscilloscope to terminals F139-6 (BLW) and F139-4 (GND) of the air conditioning amplifier assembly and check the waveform.

OK:

The waveform is the same as that shown in the diagram.

HINT:

The waveform varies depending on the blower speed.

Item

Content

Oscilloscope Setting

2 V/DIV., 1 ms/DIV.

Vehicle Operating Conditions

  • Ignition Switch in ON position
  • Blower Switch: Lo

*a

Component with Wire Harness Connected

(A/C Amplifier Assembly)

OK

REPLACE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

NG

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY