Pressure Sensor Circuit (B1423)
DESCRIPTION
This DTC is stored if the high-pressure side refrigerant pressure is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) maximum) or extremely high (2,812 kPa (28.7 kgf/cm2, 408 psi) minimum). The A/C pressure sensor, installed on the high-pressure side pipe to detect refrigerant pressure, sends a refrigerant pressure signal to the A/C amplifier assembly. The A/C amplifier assembly converts this signal into a pressure value according to the sensor characteristics and uses it to control the compressor.
DTC No. | Detection Item | DTC Detection Condition | Suspected Area | Memory |
|---|---|---|---|---|
B1423 |
Pressure Sensor Circuit |
|
|
- |
Vehicle Operating Conditions |
|||||
|---|---|---|---|---|---|
Sequence 1 | Sequence 2 | Sequence 3 | Sequence 4 |
||
Diagnostic Condition |
Ignition Switch in ON position |
○ |
○ |
○ |
○ |
Malfunction Status |
Open in Air Conditioning Pressure Sensor Circuit |
○ |
- |
- |
- |
Short in Air Conditioning Pressure Sensor Circuit |
- |
○ |
- |
- |
|
The high-pressure side refrigerant pressure is extremely low (195 kPa (2.0 kgf/cm2, 28 psi) maximum) |
- |
- |
○ |
- |
|
The high-pressure side refrigerant pressure is extremely high (2,812 kPa (28.7 kgf/cm2, 408 psi) minimum) |
- |
- |
- |
○ |
|
Detection Duration |
4 seconds minimum |
4 seconds minimum |
4 seconds minimum |
4 seconds minimum |
|
Number of Trips |
1 trip(s) |
1 trip(s) |
1 trip(s) |
1 trip(s) |
|
WIRING DIAGRAM
PRECAUTION / NOTICE / HINT
HINT:
If DTC B1423/23 and B14B8 are output simultaneously, troubleshoot DTC B14B8 first.
Click here![]()
PROCEDURE
CHECK WHETHER DTCs ARE OUTPUT
(a) Check the DTCs.
Click here![]()
Result:
Result | Proceed to |
|---|---|
DTC B14B8 is output |
A |
DTC B14B8 is not output |
B |
| A | GO TO DTC B14B8 |
|
CHECK FOR REFRIGERANT SHORTAGE
(a) Prepare the vehicle as described in the table below.
Measurement condition:Item | Condition |
|---|---|
A/C switch |
ON |
Ambient temperature* |
0 à 49 °C |
Blower speed |
HI |
*: If the ambient temperature is not within the specified range, do not perform this check.
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn on the Techstream.
(e) Select the following menu items: Body Electrical / Air Conditioner / Utility / Refrigerant Gas Volume Check.
Body Electrical > Air Conditioner > UtilityRefrigerant Gas Volume Check
Result:
Result | Refrigerant level |
|---|---|
Refrigerant Shortage |
Insufficient quantity or leak |
Proper refrigerant |
Correct |
Result:
Result | Proceed to |
|---|---|
Insufficient quantity or leak |
A |
Correct |
B |
| B | GO TO STEP 4 |
|
REPAIR A LEAK IN THE AIR CONDITIONING SYSTEM
(a) Identify the source of the refrigerant leak.
Click here![]()
(b) Repair the identified area of the air conditioning system.
(c) Evacuate the air conditioning system.
| NEXT | CHARGE THE SYSTEM WITH REFRIGERANT |
CHECK REFRIGERANT PRESSURE
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: -456.6 kPaG Max.: 3,294.3 kPaG |
Actual Refrigerant Pressure Displayed |
- |
Regulator Pressure Sensor
(f) Connect a manifold gauge set.
Click here![]()
(g) Read the manifold gauge pressure when the following conditions are met.
(1) Prepare the vehicle as indicated in the table below.
Measurement condition:Item | Condition |
|---|---|
Vehicle Doors |
Fully open |
Temperature control setting |
MAX COLD |
Blower speed |
HI |
A/C switch |
ON |
Recirculation/Fresh Air Switch |
RECIRCULATION |
Indoor Temperature |
25 à 35 °C |
Standard Pressure:
Low Pressure Side
150 to 250 kPa (1.5 to 2.5 kgf/cm2, 22 to 36 psi)
High Pressure Side
1,370 to 1,570 kPa (14 to 16 kgf/cm2, 199 to 228 psi)
(h) Compare the values displayed on the Data List and on the pressure gauge.
OK:
The values displayed on the Data List and on the pressure gauge match.
| OK | CHARGE THE SYSTEM WITH REFRIGERANT |
|
CHECK HARNESS AND CONNECTOR (POWER SOURCE CIRCUIT)
(a) Disconnect the air conditioning pressure sensor connector. |
|
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
Tester Connection | Ignition switch position | Specified Condition |
|---|---|---|
A52-3 (+) - A52-1 (-) |
Ignition Switch in ON position |
4,75 à 5,25 V |
| NG | GO TO STEP 10 |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING PRESSURE SENSOR - BODY GROUND)
(a) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-1 (-) - Body ground |
Always |
Below 1 Ω |
| NG | GO TO STEP 9 |
|
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-2 (PR) - F138-24 (PRE) |
Always |
Below 1 Ω |
A52-2 (PR) or F138-24 (PRE) - Body ground |
Always |
10 kΩ minimum |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK AIR CONDITIONING PRESSURE SENSOR (SENSOR SIGNAL CIRCUIT)
(a) Measure the voltage under the following conditions.
Measurement condition:Item | Condition |
|---|---|
Vehicle Doors |
Fully open |
Temperature control setting |
MAX COLD |
Blower speed |
HI |
A/C switch |
ON |
Recirculation/Fresh Air Switch |
RECIRCULATION |
Indoor Temperature |
25 à 35 °C |
NOTICE:
- If the high pressure side refrigerant pressure becomes extremely high during the check (voltage exceeds 4.61 V), the fail-safe function stops compressor operation. Therefore, measure the voltage before the fail-safe function activates.
- The voltage must be measured for a certain period (approximately 10 minutes), as the malfunction may reoccur after some time.
HINT:
When the outside temperature is low (below -15 °C), the compressor stops due to the operation of the thermistor assembly and No. 1 cooler thermistor (evaporator temperature sensor) in order to prevent the evaporator from freezing. In this case, perform the check indoors with the vehicle warm.
(1) Measure the voltage according to the value(s) shown in the table below. Standard voltage:
|
|
(b) Connect the Techstream to the DLC3.
(c) Turn the ignition switch to ON.
(d) Turn on the Techstream.
(e) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(f) Read the Data List by following the Techstream instructions.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: -456.6 kPaG Max.: 3,294.3 kPaG |
Actual Refrigerant Pressure Displayed |
- |
Regulator Pressure Sensor
OK:
The voltage and the value displayed on the Data List change.
Result:
Result | Proceed to |
|---|---|
OK |
A |
NG (voltage changes but the value displayed in the Data List does not change.) |
|
NG (voltage does not change). |
B |
| A | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| B | REPLACE AIR CONDITIONING PRESSURE SENSOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-1 (-) - F138-2 (SG-2) |
Always |
Below 1 Ω |
A52-1 (-) or F138-2 (SG-2) - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK HARNESS AND CONNECTOR (AIR CONDITIONER AMPLIFIER ASSEMBLY - AIR CONDITIONING PRESSURE SENSOR)
(a) Disconnect the F138 connector from the air conditioner amplifier assembly.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A52-3 (+) - F138-6 (S5-3) |
Always |
Below 1 Ω |
A52-3 (+) or F138-6 (S5-3) - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |

