Ambient Temperature Sensor Circuit (B1412)
DESCRIPTION
The thermistor assembly is mounted at the front of the cooler condenser assembly to detect the ambient temperature used to control the air conditioning system. This sensor is connected to the combination meter assembly and detects ambient temperature fluctuations. This data is used to control the cabin temperature. The sensor sends a signal to the combination meter assembly. The resistance of the thermistor assembly changes according to the ambient temperature. Resistance increases as temperature decreases. Resistance decreases as temperature increases.
The combination meter assembly applies a voltage (5 V) to the thermistor assembly and detects voltage changes based on changes in the resistance of the thermistor assembly.
DTC No. | Detection Item | DTC Detection Condition | Suspected Area | Memory |
|---|---|---|---|---|
B1412 |
Ambient Temperature Sensor Circuit |
When the air conditioning amplifier assembly does not receive data sent by the outside air temperature sensor of the combination meter assembly. |
|
Stored (4 seconds minimum)* |
- *: The A/C amplifier assembly stores this DTC if the malfunction occurs within the time period shown in parentheses.
HINT:
If the ambient temperature is approximately -52,9 °C or below, DTC B1412/12 may be output even if the system is normal.
WIRING DIAGRAM
PRECAUTION / NOTICE / HINT
NOTICE:
When replacing the instrument cluster assembly, always use a new part. If an instrument cluster assembly that was installed in another vehicle is used, the stored information will not match the information transmitted by the vehicle, and a DTC may be stored.
PROCEDURE
INSPECT CAN COMMUNICATION SYSTEM
(a) Check whether CAN communication system DTCs are output.
Click here![]()
Result:
Result | Proceed to |
|---|---|
CAN communication DTCs are not output. |
A |
CAN communication DTCs are output. |
B |
| B | GO TO CAN COMMUNICATION SYSTEM |
|
READ VALUE USING TECHSTREAM (AMBIENT TEMPERATURE)
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menus: Body Electrical / Combination Meter / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Combination Meter > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Ambient Temperature |
Ambient Temperature |
Min.: -40°C (-40°F) Max.: 88 °C |
Almost the same as the actual ambient temperature |
The multi-information display shows a temperature from -40 to 50 °C |
Ambient Temperature
OK:
The displayed value is within the specifications in the normal condition column.
Result:
Result | Proceed to |
|---|---|
NG |
A |
OK (when troubleshooting is performed based on the Symptom Chart) |
B |
OK (when troubleshooting is performed using DTC) |
C |
| B | GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE |
| C | GO TO STEP 5 |
|
INSPECT THERMISTOR ASSEMBLY
(a) Remove the thermistor assembly.
Click here![]()
(b) Inspect the thermistor assembly.
Click here![]()
| NG | REPLACE THERMISTOR ASSEMBLY |
|
INSPECT WIRE HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - COMBINATION METER ASSEMBLY)
(a) Disconnect connector A3 from the thermistor assembly.
(b) Disconnect the combination meter assembly connector F4.
(c) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
F4-34 (TEMP) - A3-2 |
Always |
Below 1 Ω |
F4-35 (TX1+) - A3-1 |
Always |
Below 1 Ω |
F4-34 (TEMP) or A3-2 - Body ground |
Always |
10 kΩ minimum |
F4-35 (TX1+) or A3-1 - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE COMBINATION METER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK WHETHER DTCs ARE OUTPUT
(a) Clear the DTCs.
Click here![]()
(b) Check DTCs.
Click here![]()
Result:
Result | Proceed to |
|---|---|
No DTCs are output |
A |
DTCs are output |
B |
| A | USE SIMULATION METHOD TO CHECK |
| B | REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY |