Heater / Air Conditioning

Data List / Active Test

~7min read

DATA LIST / ACTIVE TEST

DATA LIST

NOTICE:

In the table below, the values listed under "Normal Condition" are reference values. Do not determine whether a part is faulty based only on these reference values.

HINT:

The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.

(e) Read the Data List by following the instructions on the Techstream.

Body Electrical > Air Conditioner > Data List

Tester display

Item

Range

Normal Condition

Diagnostic Note

Room Temperature Sensor

Cooler Thermistor (Room Temperature Sensor)

Min.: -6,50 °C

Max.: 57 °C

Actual Room Temperature Displayed

-

Ambient Temp Sensor

Thermistor Assembly

Min.: -23,30 °C

Max.: 66 °C

Actual Ambient Temperature Displayed

-

Adjusted Ambient Temp

Adjusted Ambient Temperature

Min.: -30,80 °C

Max.: 51 °C

-

-

Evaporator Fin Thermistor

No. 1 Cooler Thermistor (Evaporator Temperature Sensor)

Min.: -29,70 °C

Max.: 60 °C

Actual Evaporator Temperature Displayed

-

Evaporator Target Temp

Evaporator Target Temperature

Min.: -327,68 °C

Max.: 328 °C

Evaporator Target Temperature Displayed

-

Solar Sensor (D Side)

Driver Side Solar Sensor

Min.: 0

Max.: 255

The driver side solar sensor value increases as light intensity increases

-

Solar Sensor (P Side)

Front Passenger Side Solar Sensor

Min.: 0

Max.: 255

The front passenger side solar sensor value increases as light intensity increases

-

Engine Coolant Temp

Engine coolant temperature sensor

Min.: 1.3 °C

Max.: 91 °C

Actual Engine Coolant Temperature Displayed

-

Blower Motor Speed Level

Blower Motor Speed Level

Min.: 0

Max.: 31

The displayed speed level increases from 0 to 31 as the blower motor speed increases

-

Regulator Pressure Sensor

Air Conditioning Pressure Sensor

Min.: -456.6 kPaG

Max.: 3,294.3 kPaG

Actual Refrigerant Pressure Displayed

-

Regulator Control Current

Regulator Control Current

Min.: 0 A

Max.: 0.977 A

Regulator Control Current Display

-

Air Mix Servo Targ Pulse(D)

Target Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Driver Side)

Min.: 128

Max.: 383

  • MAX COLD: 255 (pulses)
  • MAX HOT: 347 (pulses)

-

Air Mix Servo Actual Pulse(D)

Actual Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Driver Side)

Min.: 128

Max.: 383

  • MAX COLD: 255 (pulses)
  • MAX HOT: 347 (pulses)

-

Air Mix Servo Targ Pulse(P)

Target Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Front Passenger Side)

Min.: 128

Max.: 383

  • MAX COLD: 257 (pulses)
  • MAX HOT: 165 (pulses)

-

Air Mix Servo Actual Pulse(P)

Actual Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Front Passenger Side)

Min.: 128

Max.: 383

  • MAX COLD: 257 (pulses)
  • MAX HOT: 165 (pulses)

-

Air Outlet Servo Pulse (D)

Target Pulse of A/C Radiator Damper Servo Sub-assembly No. 1

Min.: 128

Max.: 383

  • FACE: 256 (pulses)
  • B/L: 267 (pulses)
  • FOOT: 297 (pulses)
  • FOOT/DEF: 320 (pulses)
  • DEF: 348 (pulses)

-

Air Outlet Servo Actu Pulse(D)

Actual Pulse of A/C Radiator Damper Servo Sub-assembly No. 1

Min.: 128

Max.: 383

  • FACE: 256 (pulses)
  • B/L: 267 (pulses)
  • FOOT: 297 (pulses)
  • FOOT/DEF: 320 (pulses)
  • DEF: 348 (pulses)

-

Air Inlet Damper Targ Pulse

Target Pulse of Blower Damper Servo Sub-assembly No. 1

Min.: 128

Max.: 383

  • Recirculation: 256 (pulses)
  • Fresh air: 220 (pulses)

-

Air Inlet Damper Actual Pulse

Actual Pulse of Blower Damper Servo Sub-assembly No. 1

Min.: 128

Max.: 383

  • Recirculation: 256 (pulses)
  • Fresh air: 220 (pulses)

-

Electric Heater Count

Maximum Electric Heater Operation Level

Min.: 0

Max.: 3

Maximum possible electric heater operation displayed

-

Electric Heater Active Level

Actual electric heater operation level

Min.: 0

Max.: 3

Displayed actual electric heater operation level

-

Shift Set Temperature

Set Temperature Change

2C decr, 1C decr, Normal, 1C incr, 2C incr

Customized display value

-

Air Inlet Mode

Air Inlet Mode

Auto or Manual

Customized display value

-

Evaporator Control

Evaporator Control

Auto or Manual

Customized display value

-

ECO MODE Cancel

ECO Drive Mode Cancellation

OFF or ON

Customized display value

-

Refrigerant Shortage Check

Refrigerant Shortage Check

ON or OFF

Customized display value

-

Fan Speed Increment Control

Fan Speed Scroll Control

Slow, Normal, Fast

Customized display value

-

Foot/DEF Auto Mode

Foot/DEF Auto Mode

ON or OFF

Customized display value

-

Foot/DEF Auto Blow Up

Foot/DEF Auto Blower Increase

ON or OFF

Customized display value

-

Refrigerant Gas Type

Refrigerant Gas Type

R134a or 1234yf

Displays refrigerant gas type

-

Set Temperature (D Side)

Driver Side Set Temperature

Min.: MAX COLD

Max.: MAX HOT

Driver side set temperature is displayed

-

Set Temperature (P Side)

Front Passenger Side Set Temperature

Min.: MAX COLD

Max.: MAX HOT

Front passenger side set temperature displayed

-

Outside Air Mode Auto Switch Function

Fresh Air Mode Auto Switch Function

ON or OFF

Customized display value

-

Number of Trouble Codes

Number of DTCs

Min.: 0

Max.: 255

Number of DTCs displayed

-

ACTIVE TEST

HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing parts. This non-intrusive functional check can be very useful, because intermittent operation can be identified before parts or wiring are moved. Performing Active Tests at the start of troubleshooting saves time during diagnosis. Data List information can be displayed during Active Tests.

(a) Connect the Techstream to the DLC3.

(b) Turn the ignition switch to ON.

(c) Turn on the Techstream.

(d) Select the following menu items: Body Electrical / Air Conditioner / Active Test.

(e) Perform the Active Test by following the Techstream instructions.

Body Electrical > Air Conditioner > Active Test

Tester display

Item

Control Range

Diagnostic Note

Blower Motor

Blower motor sub-assembly with fan

Min.: 0, Max.: 31

-

Defogger Relay (Rear)

Rear Window Defogger

OFF or ON

-

Heater Active Level

Quick heating assembly

Min.: 0, Max.: 3

-

Air Mix Servo Targ Pulse(D)

Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Driver Side Air Mix)

Min.: 128

Max.: 383

Operates between 255 and 347 pulses

Air Mix Servo Targ Pulse(P)

Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Front Passenger Side Air Mix)

Min.: 128

Max.: 383

Operates between 165 and 257 pulses

Air Outlet Servo Pulse (D)

Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Driver Side Mode)

Min.: 128

Max.: 383

Operates between 256 and 348 pulses

Air Inlet Damper Targ Pulse

Pulse of Blower Damper Servo Sub-assembly No. 1

Min.: 128

Max.: 383

Operates between 220 and 256 pulses