Data List / Active Test
DATA LIST / ACTIVE TEST
DATA LIST
NOTICE:
In the table below, the values listed under "Normal Condition" are reference values. Do not determine whether a part is faulty based only on these reference values.
HINT:
The Techstream Data List allows you to read the values or status of switches, sensors, actuators and other components without removing any parts. This non-intrusive check can be very useful, since intermittent conditions or signals can be identified before parts or wiring are moved. Reading the Data List during troubleshooting saves time in diagnosis.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Air Conditioner > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Room Temperature Sensor |
Cooler Thermistor (Room Temperature Sensor) |
Min.: -6,50 °C Max.: 57 °C |
Actual Room Temperature Displayed |
- |
Ambient Temp Sensor |
Thermistor Assembly |
Min.: -23,30 °C Max.: 66 °C |
Actual Ambient Temperature Displayed |
- |
Adjusted Ambient Temp |
Adjusted Ambient Temperature |
Min.: -30,80 °C Max.: 51 °C |
- |
- |
Evaporator Fin Thermistor |
No. 1 Cooler Thermistor (Evaporator Temperature Sensor) |
Min.: -29,70 °C Max.: 60 °C |
Actual Evaporator Temperature Displayed |
- |
Evaporator Target Temp |
Evaporator Target Temperature |
Min.: -327,68 °C Max.: 328 °C |
Evaporator Target Temperature Displayed |
- |
Solar Sensor (D Side) |
Driver Side Solar Sensor |
Min.: 0 Max.: 255 |
The driver side solar sensor value increases as light intensity increases |
- |
Solar Sensor (P Side) |
Front Passenger Side Solar Sensor |
Min.: 0 Max.: 255 |
The front passenger side solar sensor value increases as light intensity increases |
- |
Engine Coolant Temp |
Engine coolant temperature sensor |
Min.: 1.3 °C Max.: 91 °C |
Actual Engine Coolant Temperature Displayed |
- |
Blower Motor Speed Level |
Blower Motor Speed Level |
Min.: 0 Max.: 31 |
The displayed speed level increases from 0 to 31 as the blower motor speed increases |
- |
Regulator Pressure Sensor |
Air Conditioning Pressure Sensor |
Min.: -456.6 kPaG Max.: 3,294.3 kPaG |
Actual Refrigerant Pressure Displayed |
- |
Regulator Control Current |
Regulator Control Current |
Min.: 0 A Max.: 0.977 A |
Regulator Control Current Display |
- |
Air Mix Servo Targ Pulse(D) |
Target Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Driver Side) |
Min.: 128 Max.: 383 |
|
- |
Air Mix Servo Actual Pulse(D) |
Actual Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Driver Side) |
Min.: 128 Max.: 383 |
|
- |
Air Mix Servo Targ Pulse(P) |
Target Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Front Passenger Side) |
Min.: 128 Max.: 383 |
|
- |
Air Mix Servo Actual Pulse(P) |
Actual Pulse of No. 1 Air Mix Damper Servo Sub-assembly (Front Passenger Side) |
Min.: 128 Max.: 383 |
|
- |
Air Outlet Servo Pulse (D) |
Target Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 |
Min.: 128 Max.: 383 |
|
- |
Air Outlet Servo Actu Pulse(D) |
Actual Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 |
Min.: 128 Max.: 383 |
|
- |
Air Inlet Damper Targ Pulse |
Target Pulse of Blower Damper Servo Sub-assembly No. 1 |
Min.: 128 Max.: 383 |
|
- |
Air Inlet Damper Actual Pulse |
Actual Pulse of Blower Damper Servo Sub-assembly No. 1 |
Min.: 128 Max.: 383 |
|
- |
Electric Heater Count |
Maximum Electric Heater Operation Level |
Min.: 0 Max.: 3 |
Maximum possible electric heater operation displayed |
- |
Electric Heater Active Level |
Actual electric heater operation level |
Min.: 0 Max.: 3 |
Displayed actual electric heater operation level |
- |
Shift Set Temperature |
Set Temperature Change |
2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized display value |
- |
Air Inlet Mode |
Air Inlet Mode |
Auto or Manual |
Customized display value |
- |
Evaporator Control |
Evaporator Control |
Auto or Manual |
Customized display value |
- |
ECO MODE Cancel |
ECO Drive Mode Cancellation |
OFF or ON |
Customized display value |
- |
Refrigerant Shortage Check |
Refrigerant Shortage Check |
ON or OFF |
Customized display value |
- |
Fan Speed Increment Control |
Fan Speed Scroll Control |
Slow, Normal, Fast |
Customized display value |
- |
Foot/DEF Auto Mode |
Foot/DEF Auto Mode |
ON or OFF |
Customized display value |
- |
Foot/DEF Auto Blow Up |
Foot/DEF Auto Blower Increase |
ON or OFF |
Customized display value |
- |
Refrigerant Gas Type |
Refrigerant Gas Type |
R134a or 1234yf |
Displays refrigerant gas type |
- |
Set Temperature (D Side) |
Driver Side Set Temperature |
Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature is displayed |
- |
Set Temperature (P Side) |
Front Passenger Side Set Temperature |
Min.: MAX COLD Max.: MAX HOT |
Front passenger side set temperature displayed |
- |
Outside Air Mode Auto Switch Function |
Fresh Air Mode Auto Switch Function |
ON or OFF |
Customized display value |
- |
Number of Trouble Codes |
Number of DTCs |
Min.: 0 Max.: 255 |
Number of DTCs displayed |
- |
ACTIVE TEST
HINT:
Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing parts. This non-intrusive functional check can be very useful, because intermittent operation can be identified before parts or wiring are moved. Performing Active Tests at the start of troubleshooting saves time during diagnosis. Data List information can be displayed during Active Tests.
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Air Conditioner / Active Test.
(e) Perform the Active Test by following the Techstream instructions.
Body Electrical > Air Conditioner > Active TestTester display | Item | Control Range | Diagnostic Note |
|---|---|---|---|
Blower Motor |
Blower motor sub-assembly with fan |
Min.: 0, Max.: 31 |
- |
Defogger Relay (Rear) |
Rear Window Defogger |
OFF or ON |
- |
Heater Active Level |
Quick heating assembly |
Min.: 0, Max.: 3 |
- |
Air Mix Servo Targ Pulse(D) |
Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Driver Side Air Mix) |
Min.: 128 Max.: 383 |
Operates between 255 and 347 pulses |
Air Mix Servo Targ Pulse(P) |
Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Front Passenger Side Air Mix) |
Min.: 128 Max.: 383 |
Operates between 165 and 257 pulses |
Air Outlet Servo Pulse (D) |
Pulse of A/C Radiator Damper Servo Sub-assembly No. 1 (Driver Side Mode) |
Min.: 128 Max.: 383 |
Operates between 256 and 348 pulses |
Air Inlet Damper Targ Pulse |
Pulse of Blower Damper Servo Sub-assembly No. 1 |
Min.: 128 Max.: 383 |
Operates between 220 and 256 pulses |