Transmission & Driveline

P0742 Torque Converter

8steps
~48min
3/5difficulty
Done 0 of 8
DTC Description

DTC DETECTION LOGIC

DTC

CONSULT screen terms

(Trouble diagnosis content)
DTC detection condition
P0742

TORQUE CONVERTER

(Torque Converter Clutch Circuit Stuck On)
Diagnosis condition

When all of the following conditions are satisfied:

  • TCM power supply voltage: More than 11 V

  • Range: D (Except for Manual mode)

  • Accelerator pedal position : 10 deg. or more

  • Engine speed: 450 rpm or more

  • LU pressure: Less than –0.1 MPa and this state is maintained for 5 seconds

  • Secondary pulley seed: more than 0 rpm and less than 2470 rpm

Signal —
Threshold Differences between engine speed and input speed: 40 rpm or less.
Diagnosis delay time Maintained for 5 seconds or more

POSSIBLE CAUSE

  • Harness or connector (Torque converter clutch solenoid valve circuit is shorted to power supply)

  • Torque converter clutch solenoid valve

  • Torque converter

  • Control valve

FAIL-SAFE

  • Start is slow

  • Engine stops when shift to “D” position during stopping the Nissan Murano vehicle.

Confirmation Procedure

DTC CONFIRMATION PROCEDURE

PRECONDITIONING

If “DTC CONFIRMATION PROCEDURE” is previously conducted, always turn ignition switch OFF and wait at least 10 seconds before performing the next test.

>>

GO TO 2.

CHECK DTC DETECTION

  1. Start the engine.

  2. Maintain the following conditions for 5 seconds or more.

    Shift position : “D” position
    Accelerator pedal position : 1.0/8 or more
    Nissan Murano Vehicle speed : 1 - 15 km/h
    Brake pedal : Depress*

    *: Keep depressing the brake pedal moderately not to accelrate the Nissan Murano vehicle.

  3. Check the first trip DTC.

Is “P0742” detected?

YES>>

Go to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

  1. Turn ignition switch OFF.

  2. Disconnect TCM connector and CVT unit connector.

  3. Check continuity between TCM harness connector terminal and CVT unit harness connector terminal.

    TCMCVT unitContinuity
    ConnectorTerminalConnectorTerminal
    25 38 F44 5 Existed

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace malfunctioning parts.

CHECK TORQUE CONVERTER CLUTCH SOLENOID VALVE CIRCUIT

Check resistance between CVT unit harness connector terminal and ground.

CVT unit—ConditionResistance
ConnectorTerminal
F209 5 Ground CVT fluid temperature: 20 °C 5.5 – 7.0 Ω
CVT fluid temperature: 50 °C 6.0 – 8.0 Ω
CVT fluid temperature: 80 °C 6.5 – 8.5 Ω

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

GO TO 3.

CHECK CIRCUIT BETWEEN CVT UNIT AND CONTROL VALVE

  1. Disconnect control valve connector. Refer to Removal and Installation .

  2. Check continuity between CVT unit harness connector terminal and control valve harness connector terminal.

CVT unitControl valveContinuity
ConnectorTerminalConnectorTerminal
F209 5 F207 3 Existed

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Replace terminal cord assembly. Refer to Removal and Installation .

CHECK CIRCUIT BETWEEN CONTROL VALVE AND GROUND

Check resistance between control valve harness connector terminal and ground.

Control valve—ConditionResistance
Terminal
3 Ground CVT fluid temperature: 20 °C 5.5 – 7.0 Ω
CVT fluid temperature: 50 °C 6.0 – 8.0 Ω
CVT fluid temperature: 80 °C 6.5 – 8.5 Ω

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

There is malfunction of torque converter clutch solenoid valve. Replace control valve assembly. Refer to Removal and Installation .