Transmission & Driveline

P0847 Transmission Fluid Pressure Sen/sw B

15steps
~90min
4/5difficulty
Done 0 of 15
DTC Description

DTC DETECTION LOGIC

DTC

CONSULT screen terms

(Trouble diagnosis content)
DTC detection condition
P0847

FLUID PRESS SEN/SW B

(Transmission Fluid Pressure Sensor/Switch B Circuit Low)
Diagnosis condition

When all of the following conditions are satisfied:

  • CVT fluid temperature: More than −20 °C

  • TCM power supply voltage: 11 V or more

Signal —
Threshold Secondary pressure sensor voltage: 0.09 V or less
Diagnosis delay time Maintained for 5 seconds

POSSIBLE CAUSE

  • Harness or connector (Secondary pressure sensor circuit is open or shorted to ground)

  • Secondary pressure sensor

  • Control valve assembly

FAIL-SAFE

Not changed from normal driving

DTC Confirmation Procedure

PREPARATION BEFORE WORK

If another "DTC CONFIRMATION PROCEDURE" occurs just before, turn ignition switch OFF and wait for at least 10 seconds, then perform the next test.

>>

GO TO 2.

CHECK DTC DETECTION

With CONSULT

  1. Start the engine.

  2. Select “Data Monitor” in “TRANSMISSION”.

  3. Select “FLUID TEMP”.

  4. Maintain the following conditions for 10 seconds or more.

    FLUID TEMP : −20 °C
  5. Check the first trip DTC.

With GST

  1. Start the engine and wait for at least 10 seconds.

  2. Check the first trip DTC.

Is “P0847”detected?

YES>>

Go to Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

Diagnosis Procedure

CHECK TCM INPUT SIGNALS

  1. Turn ignition switch OFF.

  2. Start the engine.

  3. Check voltage between TCM harness connector terminals.

    +−ConditionVoltage
    TCM
    ConnectorTerminal
    F25 16 Ground
    • Selector lever: “N” position

    • At idle

    1.7 – 1.8 V

Is the inspection result normal?

YES>>

Check intermittent incident. Refer to Intermittent Inciden.

NO>>

GO TO 2.

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 1)

  1. Turn ignition switch OFF.

  2. Disconnect TCM connector and CVT unit connector.

  3. Check continuity between TCM harness connector terminals and CVT unit harness connector terminals.

    TCMCVT unitContinuity
    ConnectorTerminalConnectorTerminal
    F25 11 F44 18 Existed
    16 14
    26 22

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace malfunctioning parts.

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT (PART 2)

Check continuity between TCM harness connector terminals and ground.

TCM—Continuity
ConnectorTerminal
F25 16 Ground Not existed
26

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Repair or replace malfunctioning parts.

CHECK TERMINAL CORD ASSEMBLY (PART 1)

  1. Remove terminal cord assembly. Refer to Removal and Installation.

  2. Check continuity between CVT unit harness connector terminals and control valve harness connector terminals.

    CVT unitControl valveContinuity
    ConnectorTerminalConnectorTerminal
    F210 14 F207 12 Existed
    18 13
    22 11

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

Repair or replace malfunctioning parts.

CHECK TERMINAL CORD ASSEMBLY (PART 2)

Check damage of terminal cord assembly.

Is the inspection result normal?

YES>>

There is malfunction of secondary pressure sensor. Replace control valve assembly. Refer to Removal and Installation.

NO>>

Repair or replace malfunctioning parts.