Transmission & Driveline

P2758 Tcc Pressure Control Solenoid

10steps
~60min
4/5difficulty
Done 0 of 10
DTC Description

DTC DETECTION LOGIC

DTC

CONSULT screen terms

(Trouble diagnosis content)
DTC detection condition
P2758

TCC PRESSURE CONT SOLENOID

(Torque Converter Clutch Pressure Control Solenoid Control Circuit Stuck On)
Diagnosis condition

When all of the following conditions are satisfied:

  • TCM power supply voltage: More than 11 V

  • Lockup value learning is completed (After ignition switch ON)

Signal —
Threshold Coast capacity learning value: Less than –0.2 Mpa
Diagnosis delay time —

POSSIBLE CAUSE

  • Harness or connector (Torque converter clutch solenoid valve circuit is open or shorted to power supply)

  • Torque converter clutch solenoid valve

  • Control valve

FAIL-SAFE

  • Start is slow

  • Engine stops when shift to “D” position during stopping the Nissan Murano vehicle.

Confirmation Procedure

DTC CONFIRMATION PROCEDURE

PRECONDITIONING

If “DTC CONFIRMATION PROCEDURE” is previously conducted, always turn ignition switch OFF and wait at least 10 seconds before performing the next test.

>>

GO TO 2.

CHECK DTC DETECTION

  1. Start the engine.

  2. Shift the selector lever to D position.

  3. Fully depress the accelerator pedal and accelerate by reaching 100 km/h.

    And then release the accelerator pedal.

  4. Depress the accelerator pedal half way for 10 seconds.

  5. Check the first trip DTC.

Is “P2758” detected?

YES>>

Go to Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

Diagnosis Procedure

CHECK CIRCUIT BETWEEN TCM AND CVT UNIT

  1. Turn ignition switch OFF.

  2. Disconnect TCM connector and CVT unit connector.

  3. Check continuity between TCM harness connector terminal and CVT unit harness connector terminal.

    TCMCVT unitContinuity
    ConnectorTerminalConnectorTerminal
    F25 38 F44 5 Existed

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace malfunctioning parts.

CHECK TORQUE CONVERTER CLUTCH SOLENOID VALVE CIRCUIT

Check resistance between CVT unit harness connector terminal and ground.

CVT unit—ConditionResistance
ConnectorTerminal
F210 5 Ground CVT fluid temperature: 20 °C 5.5 – 7.0 Ω
CVT fluid temperature: 50 °C 6.0 – 8.0 Ω
CVT fluid temperature: 80 °C 6.5 – 8.5 Ω

Is the inspection result normal?

YES>>

Check intermittent incident. Refer to Intermittent Incident.

NO>>

GO TO 3.

CHECK CIRCUIT BETWEEN CVT UNIT AND CONTROL VALVE

  1. Disconnect control valve connector. Refer to Removal and Installation.

  2. Check continuity between CVT unit harness connector terminal and control valve harness connector terminal.

CVT unitControl valveContinuity
ConnectorTerminalConnectorTerminal
F210 5 F207 3 Existed

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Replace terminal cord assembly. Refer to Removal and Installation.

CHECK CIRCUIT BETWEEN CONTROL VALVE AND GROUND

Check resistance between control valve harness connector terminal and ground.

Control valve—ConditionResistance
Terminal
3 Ground CVT fluid temperature: 20 °C 5.5 – 7.0 Ω
CVT fluid temperature: 50 °C 6.0 – 8.0 Ω
CVT fluid temperature: 80 °C 6.5 – 8.5 Ω

Is the inspection result normal?

YES>>

Check intermittent incident. Refer to Intermittent Incident.

NO>>

There is malfunction of torque converter clutch solenoid valve. Replace control valve assembly. Refer to Removal and Installation.