P0131 A/f Sensor 1
DTC DETECTION LOGIC
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1 signal is not inordinately low.
The A/F signal computed by ECM from the A/F sensor 1 signal is constantly approx. 0 V.
| DTC | CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition | |
| P0131 | A/F SENSOR1 (B1) (O2 sensor circuit low voltage bank 1 sensor 1) |
Diagnosis condition | — |
| Signal (terminal) | The A/F signal computed by ECM | ||
| Threshold | The A/F signal computed by ECM from the A/F sensor 1 signal is constantly approx. 0 V | ||
| Diagnosis delay time | — | ||
| P0151 | A/F SENSOR1 (B2) (O2 sensor circuit high voltage bank 2 sensor 1) |
Diagnosis condition | — |
| Signal (terminal) | The A/F signal computed by ECM | ||
| Threshold | The A/F signal computed by ECM from the A/F sensor 1 signal is constantly approx. 0 V | ||
| Diagnosis delay time | — | ||
POSSIBLE CAUSE
P0131
Harness or connectors (The A/F sensor 1 circuit is open or shorted.)
A/F sensor 1
P0151
Harness or connectors (The A/F sensor 1 circuit is open or shorted.)
A/F sensor 1
FAIL-SAFE
Not applicable
PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following before conducting the next test.
Turn ignition switch OFF and wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5 V at idle.
>>GO TO 2.
CHECK A/F SENSOR 1 FUNCTION
With CONSULT
Start engine and warm it up to normal operating temperature.
Select “A/F SEN1 (B1)” or “A/F SEN1 (B2)” in “DATA MONITOR” mode with CONSULT.
Check “A/F SEN1 (B1)” or “A/F SEN1 (B2)” indication.
With GST
Follow the procedure “With CONSULT” above.
Is the indication constantly approx. 0 V?
YES>>Proceed to Diagnosis Procedure.
NO>>GO TO 3.
PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT
Turn ignition switch OFF, wait at least 10 seconds.
Turn ignition switch ON.
Turn ignition switch OFF, wait at least 10 seconds and then restart engine.
Drive and accelerate Nissan Murano vehicle to more than 40 km/h within 20 seconds after restarting engine.
Maintain the following conditions for approximately 20 consecutive seconds.
ENG SPEED 1,000 - 3,200 rpm VHCL SPEED SE More than 40 km/h B/FUEL SCHDL 1.5 - 9.0 msec Selector lever Suitable position Check 1st trip DTC.
With GST
Follow the procedure “With CONSULT” above.
Is 1st trip DTC detected?
YES>>Proceed to Diagnosis Procedure.
NO>>To check malfunction symptom before repair: Refer to Intermittent Incident.
NO>>Confirmation after repair: INSPECTION END
CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY
Disconnect A/F sensor 1 harness connector.
Turn ignition switch ON.
Check the voltage between A/F sensor 1 harness connector and ground.
DTC A/F sensor 1 Ground Voltage Bank Connector Terminal P0131 1 F12 1 Ground Battery voltage P0151 2 F61 1
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect IPDM E/R harness connector.
Check the continuity between A/F sensor 1 harness connector and IPDM E/R harness connector.
| DTC | A/F sensor 1 | IPDM E/R | Continuity | |||
|---|---|---|---|---|---|---|
| Bank | Connector | Terminal | Connector | Terminal | ||
| P0131 | 1 | F12 | 1 | F19 | 52 | Existed |
| P0151 | 2 | F61 | 1 | 53 | ||
Is the inspection result normal?
YES>>Perform the trouble diagnosis for power supply circuit.
NO>>Repair or replace error-detected parts.
CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between A/F sensor 1 harness connector and ECM harness connector .
DTC A/F sensor 1 ECM Continuity Bank Connector Terminal Connector Terminal P0131 1 F12 3 F79 66 Existed 4 67 P0151 2 F61 3 76 4 77 Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.
DTC A/F sensor 1 Ground Continuity Bank Connector Terminal P0131 1 F12 3 Ground Not existed 4 P0151 2 F61 3 4 DTC ECM Ground Continuity Connector Terminal P0131 F79 66 Ground Not existed 67 P0151 76 77 Also check harness for short to power.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Repair open circuit, short to ground or short to power in harness or connectors.