Refrigerant Pressure Sensor
CHECK REFRIGERANT PRESSURE SENSOR FUNCTION
Start engine and warm it up to normal operating temperature.
Turn A/C switch and blower fan switch ON.
Check the voltage between ECM harness connector terminals under the following conditions.
ECM Voltage (V) Connector + – Terminal F78 20 25 1.0 - 4.0
Is the inspection result normal?
YES>>INSPECTION END
NO>>Proceed to Diagnosis Procedure.
CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY
Disconnect refrigerant pressure sensor harness connector.
Turn ignition switch ON.
Check the voltage between refrigerant pressure sensor harness connector and ground.
+ − Voltage (V) Refrigerant pressure sensor Connector Terminal E244 1 Ground Approx. 5
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 2.
CHECK REFRIGERANT PRESSURE SENSOR POWER SUPPLY CIRCUIT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
| Refrigerant pressure sensor | ECM | Continuity | ||
|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |
| E244 | 1 | F78 | 18 | Existed |
Is the inspection result normal?
YES>>Check sensor power supply 2 circuit. Refer to Diagnosis Procedure.
NO>>Repair or replace error-detected parts.
CHECK REFRIGERANT PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
Turn ignition switch OFF.
Disconnect ECM harness connector.
Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E244 3 F78 25 Existed Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>GO TO 4.
NO>>Repair or replace error-detected parts.
CHECK REFRIGERANT PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
Check the continuity between refrigerant pressure sensor harness connector and ECM harness connector.
Refrigerant pressure sensor ECM Continuity Connector Terminal Connector Terminal E244 2 F78 20 Existed Also check harness for short to ground and short to power.
Is the inspection result normal?
YES>>GO TO 5.
NO>>Repair or replace error-detected parts.
CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent Incident.
Is the inspection result normal?
YES>>Replace refrigerant pressure sensor. Refer to Removal and Installation.
NO>>Repair or replace error-detected parts.