Front fog light circuit
DESCRIPTION
The main body ECU (multiplex network body ECU) controls the front fog lights.
WIRING DIAGRAM
PRECAUTION / NOTICE / HINT
NOTICE:
- Check the fuses and bulbs for the circuits related to this system before performing the following procedure.
- Before replacing the main body ECU (multiplex network body ECU), refer to the registration section.*1
Click here
.gif)
- *1: with Smart Key System
PROCEDURE
CHECK OPERATION (REAR LIGHTS)
(a) Check the operation of the rear lights.
OK:
The rear lights operate normally.
| NG | REFER TO SYMPTOM TROUBLESHOOTING TABLE |
|
PERFORM ACTIVE TEST USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menu items: Body Electrical / Main Body / Active Test.
(e) Perform the Active Test by following the Techstream instructions.
Body Electrical > Main Body > Active TestTester display | Item | Control Range | Diagnostic Note |
|---|---|---|---|
Front Fog Light Relay |
Front Fog Lights |
ON / OFF |
Light Control Switch in TAIL position |
Front Fog Light Relay
OK:
The front fog lights come on.
| OK | GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE |
|
CHECK WIRE HARNESS AND CONNECTOR (FR FOG RELAY - BATTERY)
(a) Remove the FR FOG relay from the No. 4 relay block assembly.
(b) Measure the voltage according to the value(s) in the table below.
Standard voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Relay terminal 5 - Body ground |
Always |
11 à 14 V |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK WIRE HARNESS AND CONNECTOR (FRONT FOG LIGHT RELAY INPUT VOLTAGE)
(a) Measure the voltage according to the value(s) shown in the table below.
Standard voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Relay terminal 2 - Body ground |
Light control switch in TAIL or HEAD position |
11 à 14 V |
| NG | GO TO STEP 9 |
|
CHECK FRONT FOG LIGHT RELAY
(a) Check the FR FOG relay.
Click here![]()
| NG | REPLACE FR FOG RELAY |
|
CHECK WIRE HARNESS AND CONNECTOR (FR FOG RELAY - RH FOG LIGHT ASSEMBLY AND LH FOG LIGHT ASSEMBLY)
(a) Disconnect connector A36 from the LH fog light assembly.
(b) Disconnect connector A35 from the RH fog light assembly.
(c) Measure the voltage according to the value(s) shown in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Relay terminal 3 - A36-2 (B) |
Always |
Below 1 Ω |
Relay terminal 3 - A35-2 (B) |
Always |
Below 1 Ω |
Relay terminal 3 or A36-2 (B) - Body ground |
Always |
10 kΩ minimum |
Relay terminal 3 or A35-2 (B) - Body ground |
Always |
10 kΩ minimum |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK WIRE HARNESS AND CONNECTOR (FR FOG RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
(a) Disconnect connector 3A from the instrument panel junction block assembly.
(b) Measure the voltage according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Relay terminal 1 - 3A-52 |
Always |
Below 1 Ω |
Relay terminal 1 or 3A-52 - Body ground |
Always |
10 kΩ minimum |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
(a) Remove the instrument panel junction block assembly.
Click here![]()
(b) Remove the main body ECU (multiplex network body ECU) from the instrument panel junction block assembly.
(c) Measure the resistance according to the value(s) in the table below.
*a |
Component without wire harness connected (instrument panel junction block assembly) |
- |
- |
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
3A-52 - MB-7 (FFGO) |
Always |
Below 1 Ω |
| OK | REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) |
| NG | REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
CHECK WIRE HARNESS AND CONNECTOR (FR FOG RELAY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
(a) Disconnect connector 3D from the instrument panel junction block assembly.
(b) Measure the voltage according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
Relay terminal 2 - 3D-11 |
Always |
Below 1 Ω |
Relay terminal 2 or 3D-11 - Body ground |
Always |
10 kΩ minimum |
| OK | REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |