Hazard Warning Switch Circuit
DESCRIPTION
The combination meter assembly receives the hazard switch assembly ON signal and controls the operation of the hazard lights.
WIRING DIAGRAM
PRECAUTION / NOTICE / HINT
NOTICE:
When replacing the instrument cluster assembly, always use a new part. If an instrument cluster assembly that was installed in another vehicle is used, the stored information will not match the information transmitted by the vehicle, and a DTC may be stored.
PROCEDURE
CHECK VALUE USING TECHSTREAM
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Turn on the Techstream.
(d) Select the following menus: Body Electrical / Combination Meter / Data List.
(e) Read the Data List by following the instructions on the Techstream.
Body Electrical > Combination Meter > Data ListTester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Hazard Flasher Switch |
Hazard warning switch signal |
ON or OFF |
ON: Hazard warning switch in ON position OFF: Hazard warning switch in OFF position |
- |
Hazard Flasher Switch
OK:
The normal conditions listed above are displayed.
| OK | GO TO APPLICABLE SYSTEM AS INDICATED IN THE PROBLEM SYMPTOMS TABLE |
|
CHECK HAZARD SIGNAL SWITCH ASSEMBLY
(a) Remove the hazard signal switch assembly.
Click here![]()
(b) Check the hazard switch assembly.
Click here![]()
OK:
The hazard signal switch assembly is normal.
| NG | REPLACE HAZARD SIGNAL SWITCH ASSEMBLY |
|
CHECK WIRE HARNESS AND CONNECTOR (HAZARD SIGNAL SWITCH ASSEMBLY - COMBINATION METER ASSEMBLY OR BODY GROUND)
(a) Disconnect the F5 combination meter assembly connector.
(b) Measure the resistance according to the value(s) in the table below.
Standard resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
F62-4 (TB) - F5-3 (HAZ) |
Always |
Below 1 Ω |
F62-4 (TB) or F5-3 (HAZ) - Body ground |
Always |
10 kΩ minimum |
F62-1 (E) - Body ground |
Always |
Below 1 Ω |
| OK | REPLACE COMBINATION METER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |