Engine Room Junction Block Removal and Installation
Removal
Engine Room PCB Block
Disconnect the negative ( - ) battery terminal.
Disconnect the engine room PCB block connector (A).
Remove the engine room PCB block (A) by pulling the hooks in the direction of the arrows.
Disconnect the engine room PCB block connectors (A).
Installation
Install in reverse order of removal.
Engine Room Junction Block Inspection
Inspection
Power Relay Inspection (Type A) Check for continuity between the terminals.
After supplying power between terminal No. 85 and 86, check that there is continuity between terminal No. 30 and 87.
After supplying power between terminal No. 85 and 86, check that there is no continuity between terminal No. 30 and 87.
Terminal
Operate
Power ON
Power OFF
30 - 87
Continuity
-
After supplying power between terminal No. 86 and 85, check that there is continuity between terminal No. 87 and 30.
After supplying power between terminal No. 86 and 85, check that there is no continuity between terminal No. 87 and 30.
Terminal
Operate
Power ON
Power OFF
30 - 87
Continuity
-
Check for separation of fuse holder and check that the holder is tightly holding the fuse.
Check that each fuse circuit has the exact fuse capacity.
Check the fuses for any damage.
If a fuse is to be replaced, be sure to use a new fuse of the same capacity.
Disconnect the negative ( - ) battery terminal.
Remove the terminals (A) after removing the nuts.
Remove the multi-fuse (A) by pulling the hooks in the direction of the arrows.
Remove the multi-fuse (B) by pulling the hooks in the direction of the arrows and then remove the multi-fuse (C).
Check the multi-fuses for any damage.
Use the multi-fuse of the exact fuse capacity.
Power Relay (Type B) Check for continuity between the terminals. Fuse Multi-Fuse
Integrated Central Control Unit (ICU) Description and Operation
Description
The Integrated Central Control Unit (ICU) is the next-generation model of the Integrated Gateway and Power Control Module (IGPM).
System Block Diagram
ICU Operating Function
Item
Function
Function
Switch Input
Receives switch inputs and then sends the switch status to each module via CAN message.
Lamp control
Controls lamp with the IPS by receiving command from IBU via CAN message.
Internal relay control
Controls internal relay by receiving command from IBU via CAN message.
External relay control
Controls external relay by receiving command from IBU via CAN message.
Parasitic current shut-off system
The system automatically shuts off the power to be provided with components for reducing useless parasitic current according to the vehicle operating conditions such as shipment and long-term parking.
Troubleshooting
Diagnose status of loads controlled by IPS.
Gateway
Transmits signals among the modules connected to the different networks in the vehicle.
※The ICU does not determine logic, it is operated only by CAN commands from other modules. ▶ Self-Logic Function : Hazard lamp, stop lamp, steering wheel heater Switch Input
Operating Function ▶ Hazard lamp switch, seat belt switch, tailgate switch, door switch, etc.
Operating Description
Determined switch operation status
Switch status messages are sent to other modules (IBU, DAU, PSM, etc.) via CAN communication.
Operating Function ▶ Headlamp low/high, turn signal lamp, DRL lamp, internal/external tail lamp, stop lamp, etc.
Operating Description
Lamp ON/OFF operation via CAN message of IBU
Detects current flowing through the lamp via IPS
Lamp OFF when over-current detection (PCL control : Shut-off current of lamp if reference current is exceeded) ※ IPS can replace fuse and relay functions by applying semi-conductors, and there is also a circuit break function to protect devices from overheating/overcurrent.
Operating Function ▶ Burglar alarm horn, tailgate, power window, etc
Operating Description
Relay ON/OFF operation via CAN message of IBU
Operating Function ▶ Headlamp high solenoid, rear fog, rear glass defogger, etc.
Operating Description
Relay ON/OFF operation via CAN message of IBU
Operating Description
If the CAN and switch inputs are absent for a long time, the power output is turn off sequentially to prevent battery discharge.
If a CAN or switch input is received while the parasitic current shut-off system is operating, the system is disabled for normal operation.
IPS Lamp control Internal relay control External relay control Parasitic current shut-off system
Integrated Central Control Unit (ICU) Inspection
Inspection
fuse
Check for separation of fuse holder and check that the holder is tightly holding the fuse.
Check that each fuse circuit has the exact fuse capacity.
Check the fuses for any damage.
If a fuse is to be replaced, be sure to use a new fuse of the same capacity.
Integrated Central Control Unit (ICU) Removal and Installation
Removal
Remove the crash pad lower panel. (Refer to Body - "Crash Pad Lower Panel")
Disconnect the integrated central control unit (ICU) connectors (A).
Remove the Integrated Central Control Unit (ICU) (A) after removing the bolt and nuts.
Disconnect the integrated central control unit (ICU) connectors (A).
Remove the wiring clip (A).
Installation
Install in reverse order of removal.
Integrated Circuit Module (ICM) Removal and Installation
Removal
Remove the crash pad lower panel. (Refer to Body - "Crash Pad Lower Panel")
Disconnect the Integrated Circuit Module (ICM) connectors (A).
Remove the Integrated Circuit Module (ICM) (A) after removing the nuts.