Body Electrical System
Keyless Entry And Burglar Alarm
In this manual: Body Electrical System
5steps
~30min
2/5difficulty
Done 0 of 5
Contents:
Specifications
Specification
| Item | Specification |
| Operating voltage (V) | 9 - 16 |
| Current consumption (A) | Maximum 3.5 |
| Sound level (dB) | 111 ± 3 |
| Insulation resistance (MΩ) | Minimum 1 |
Description and Operation ➤
Removal and Installation
Removal
Burglar Alarm Horn- Disconnect the battery negative ( - ) terminal.
- Disconnect the burglar alarm horn connector (A).

- Remove the burglar alarm horn (A) by removing the bolt.

Installation
- Install in the reverse of the removal.
Inspection
Inspection
- Apply battery voltage to terminal 1 (ground) and terminal 2 (battery+) and verify that it operates.

- Check the fuse and relay.

- The semi-conductor type relay inserted in the PCB is impossible to replace. If the relay needs to be replaced, replace the metal core box and conduct a test on it. (Refer to Fuses And Relays - "Engine Room Junction Block")