Relay
On-vehicle Inspection
ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT H-LP LH RELAY
*a |
Component without harness connected (H-LP LH Relay) |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
3 - 5 |
Voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
3 - 5 |
Voltage applied between terminals 1 and 2 |
Below 1 Ω |
If the result is not as specified, replace the H-LP LH relay.
2. INSPECT H-LP RH RELAY
*a |
Component without harness connected (H-LP RH Relay) |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
3 - 5 |
Voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
3 - 5 |
Voltage applied between terminals 1 and 2 |
Below 1 Ω |
If the result is not as specified, replace the H-LP RH relay.
3. INSPECT DIM RELAY (w/o Cornering Light)
*a |
Component without harness connected (DIM Relay) |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
3 - 5 |
Voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
3 - 5 |
Voltage applied between terminals 1 and 2 |
Below 1 Ω |
If the result is not as specified, replace the DIM relay.
4. INSPECT DRL RELAY (w/o Cornering Light)
*a |
Component without harness connected (DRL Relay) |
(a) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
3 - 5 |
Voltage not applied between terminals 1 and 2 |
10 kΩ or higher |
3 - 5 |
Voltage applied between terminals 1 and 2 |
Below 1 Ω |
If the result is not as specified, replace the DRL relay.