Brake Control / Dynamic Control Systems

ECU Terminals

~5min read

ECU TERMINALS

ECU TERMINALS

*a

Component without wire harness connected

Skid control ECU (brake actuator assembly)

-

-

Terminal No. (Symbol)

Terminal Description

1 (+BM)

ABS motor relay power supply

2

-

3

-

4

- (not used)

5 (CANH)

CAN H communication line

6 (CSW)

VSC OFF switch input

7 (FL-)

Front left wheel speed signal input (-)

8

- (not used)

9

- (not used)

10 (STPO)

Stop light relay control output

11

- (not used)

12

-

13

-

14 (GND2)

Pump motor ground

15

-

16

-

17 (FSW+)

Brake pedal force sensor switch input

18

- (not used)

19 (CANL)

CAN L communication line

20

- (not used)

21 (FR+)

Front right wheel speed signal input (+)

22 (RR+)

Rear right wheel speed signal input (+)

23 (RL-)

Rear left wheel speed signal input (-)

24 (FL+)

Front left wheel speed signal input (+)

25

- (not used)

26 (FR-)

Front right wheel speed signal input (-)

27

- (not used)

28

- (not used)

29

- (not used)

30 (+BS)

ABS solenoid valve relay power supply

31

-

32

-

33

-

34 (SP1)

Speed signal output to speedometer

35

-

36 (IG1)

IG1 power supply input

37 (RR-)

Rear right wheel speed signal input (-)

38

- (not used)

39 (RL+)

Rear left wheel speed signal input (+)

40

- (not used)

41

- (not used)

42 (STP)

Stop light relay control input

43 (HZRI)

Brake hold switch input

44 (STP2)

Stop light switch input

45

-

46 (GND1)

Skid control ECU ground

TERMINAL INSPECTION

(a) Disconnect the connector and measure the voltage and resistance at the wire harness side.

HINT:

Voltage cannot be measured while the connector is connected to the skid control ECU (brake actuator assembly), because the connector is waterproof.

Standard

Terminal No. (Symbol)

Wire Color

Terminal Description

Condition

Specified Condition

A42-1 (+BM) - Body ground

L - Body ground

ABS motor relay power supply

Always

11 à 14 V

A42-6 (CSW) - Body ground

R - Body ground

VSC OFF switch input

VSC OFF switch ON → OFF (pressed → released)

Below 1 Ω → 10 kΩ or higher

A42-10 (STPO) - Body ground

R - Body ground

Stop light relay control output (stop light switch assembly)

Ignition Switch in ON position

11 à 14 V

A42-14 (GND2) - Body ground

W-B - Body ground

Pump motor ground

Always

Below 1 Ω

A42-17 (FSW+) - Body ground

GR - Body ground

Brake pedal force sensor switch input

Brake pedal force sensor switch OFF → ON (brake pedal depressed → released)

950 à 1 050 Ω → 203 à 223 Ω

A42-30 (+BS) - Body ground

W - Body Ground

ABS solenoid valve relay power supply

Always

11 à 14 V

A42-36 (IG1) - Body ground

B - Body ground

IG1 power supply input

Ignition Switch in ON position

11 à 14 V

A42-42 (STP) - Body ground

SB - Body ground

Stop light relay control output (stop light switch assembly)

Stop light switch ON → OFF (brake pedal depressed → released)

11 to 14 V* → Below 1.5 V

A42-43 (HZRI) - Body ground

B - Body ground

Brake hold switch input

Brake hold switch ON → OFF (released → depressed)

Below 1 Ω → 10 kΩ or higher

A42-44 (STP2) - Body ground

L - Body ground

Stop light switch input

Stop light switch assembly ON → OFF (brake pedal depressed → released)

11 to 14 V* → Below 1.5 V

A42-46 (GND1) - Body ground

W-B - Body ground

Skid control ECU ground

Always

Below 1 Ω

HINT:

*: The standard value varies depending on the voltage at terminal +BS. The standard voltage is 85% of the voltage at terminal +BS.

*a

Front view of wire harness connector (to skid control ECU (brake actuator assembly))