Open in Stop Light Switch Circuit (C1249)
DESCRIPTION
The skid control ECU (brake actuator assembly) receives signals from the stop light switch and uses them to determine whether the brakes are applied. DTCs may be stored in any of the following situations:
- Stop light switch connector is stuck due to a malfunction.
- The accelerator and brake pedals are depressed at the same time.*
HINT:
*: The skid control ECU (brake actuator assembly) may store this DTC if a malfunction is detected in the evaluation while the stop light switch is stuck ON and the accelerator and brake pedals are depressed at the same time. However, this does not necessarily indicate a malfunction.
DTC No. | Detection Item | DTC Detection Condition | Suspected Area |
|---|---|---|---|
C1249 |
Open circuit in stop light switch circuit |
The vehicle speed is greater than 10 km/h, the accelerator pedal is depressed, the master cylinder pressure is 0.5 MPa (5.09 kgf/cm2, 72 psi) or less, and the stop light switch is ON for at least 60 seconds. |
|
WIRING DIAGRAM
PRECAUTION / NOTICE / HINT
NOTICE:
- When replacing the Skid Control ECU (Brake Actuator Assembly), perform system variant coding.
Click here
.gif)
- Check the fuses for the circuits related to this system before performing the following procedure.
PROCEDURE
CHECK BRAKE PEDAL AND ACCELERATOR PEDAL OPERATION
(a) Ask the customer whether the pedals were depressed at the same time, while the vehicle was moving, or during braking.
OK:
The pedals were not depressed at the same time.
HINT:
The skid control ECU (brake actuator assembly) may store this DTC if it detects a malfunction when the accelerator pedal and brake pedal are depressed at the same time while the stop light switch is stuck ON.
If the pedals were depressed at the same time, be sure to clear the DTCs, as this is not a malfunction.
| NG | GO TO STEP 9 |
|
CHECK STOP LIGHT OPERATION
(a) Check that the stop lights come on when the brake pedal is depressed and go off when the brake pedal is released.
OK:
Condition | Light Condition |
|---|---|
Brake pedal depressed. |
ON |
Brake pedal released. |
OFF |
| NG | GO TO STEP 6 |
|
READ VALUE USING TECHSTREAM (STOP LIGHT SWITCH ASSEMBLY)
(a) Connect the Techstream to the DLC3.
(b) Turn the ignition switch to ON.
(c) Select the Data List using the Techstream.
Click here![]()
Tester display | Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
Stop Light SW |
Stop light switch |
ON or OFF |
ON: Brake pedal depressed OFF: Brake pedal released |
- |
Stop Light SW
(d) Check that the stop light switch status shown on the Techstream changes according to brake pedal operation.
OK:
The Techstream shows ON or OFF according to brake pedal operation.
| NG | GO TO STEP 5 |
|
CONFIRM DTC AGAIN
(a) Turn the ignition switch OFF.
(b) Clear the DTCs.
Click here![]()
(c) Turn the ignition switch to OFF.
(d) Start the engine.
(e) Drive the vehicle and release the brake pedal several times to test the stop light circuit.
(f) Check whether the same DTC is output.
Click here![]()
Result:
Result | Proceed to |
|---|---|
DTC C1249 is not stored. |
A |
DTC C1249 is stored. |
B |
HINT:
If troubleshooting was performed according to the symptom chart, refer to the chart and go to the next step before replacing parts.
Click here![]()
| A | USE SIMULATION METHOD TO CHECK |
| B | REPLACE BRAKE ACTUATOR ASSEMBLY |
CHECK HARNESS AND CONNECTOR (STP TERMINAL)
(a) Turn the ignition switch OFF. |
|
(b) Check that the connector lock and connection have no looseness.
(c) Disconnect connector A42 from the skid control ECU (brake actuator assembly).
(d) Measure the voltage according to the value(s) specified in the table below.
Standard voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A42-44 (STP2) - Body ground |
Stop light switch ON (brake pedal depressed) |
11 à 14 V* |
A42-44 (STP2) - Body ground |
Stop light switch OFF (brake pedal released) |
Below 1.5 V |
HINT:
*: The standard value varies depending on the voltage at terminal +BS. The standard voltage is 85% of the voltage at terminal +BS.
HINT:
If troubleshooting was performed according to the symptom chart, refer to the chart and go to the next step before replacing parts.
Click here![]()
| OK | REPLACE BRAKE ACTUATOR ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR (STP CIRCUIT) |
CHECK STOP LIGHT SWITCH ASSEMBLY
(a) Inspect the stop light switch assembly.
Click here![]()
OK:
The stop light switch assembly is normal.
| NG | REPLACE STOP LIGHT SWITCH ASSEMBLY |
|
CHECK HARNESS AND CONNECTOR (STP TERMINAL)
(a) Reconnect connector A1 of the stop light switch assembly. |
|
(b) Check that the connector lock and connection have no looseness.
(c) Disconnect connector A42 from the skid control ECU (brake actuator assembly).
(d) Measure the voltage according to the value(s) specified in the table below.
Standard voltage:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A42-44 (STP2) - Body ground |
Stop light switch ON (brake pedal depressed) |
11 à 14 V* |
A42-44 (STP2) - Body ground |
Stop light switch OFF (brake pedal released) |
Below 1.5 V |
HINT:
*: The standard value varies depending on the voltage at terminal +BS. The standard voltage is 85% of the voltage at terminal +BS.
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR (STP CIRCUIT) |
|
CONFIRM DTC AGAIN
(a) Reconnect connector A42 to the skid control ECU (brake actuator assembly).
(b) Clear the DTCs.
Click here![]()
(c) Turn the ignition switch to OFF.
(d) Start the engine.
(e) Drive the vehicle and release the brake pedal several times to test the stop light circuit.
(f) Check whether the same DTC is output.
Click here![]()
Result:
Result | Proceed to |
|---|---|
DTC C1249 is not stored. |
A |
DTC C1249 is stored. |
B |
HINT:
If troubleshooting was performed according to the symptom chart, refer to the chart and go to the next step before replacing parts.
Click here![]()
| A | CHECK LIGHTING SYSTEM (STOP LIGHT CIRCUIT) |
| B | REPLACE BRAKE ACTUATOR ASSEMBLY |
CLEAR DTCs
(a) Clear the DTCs.
Click here![]()
| NEXT | END |
.png)