DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure (P0E5128). DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold (P0E5717). DC/DC Converter Tem
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure (P0E5128)
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC is stored when an abnormal current sensor output signal is detected. The cause of this malfunction may be one of the following:
Internal inverter malfunction- Current sensor malfunction
- Inverter with converter assembly internal circuit malfunction
DESCRIPTION
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0E5128 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
Reactor current sensor offset malfunction When current is essentially not flowing, the reactor current sensor output is outside a certain range. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
If the motor generator control ECU detects a reactor current sensor offset malfunction, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0E52 (INF P0E5128): DC/DC Converter Current Sensor Circuit Range/Performance |
Required sensors/components |
DC/DC Converter Current Sensor Circuit |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0E52 (INF P0E5128) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- Turn the power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0E5128 only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
P0A1A49 |
Generator Control Module Internal Electronic Failure |
||
P0A1B1F |
Generator Control Module Circuit Intermittent |
||
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
||
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
||
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
||
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
||
P313383 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
||
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
||
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
||
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
||
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
||
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
||
Hybrid control system |
P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure |
|
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
Communication malfunction |
Motor generator control system |
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid control system |
P312387 |
Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
|
HINT:
- P0E5128 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| A | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold (P0E5717)
DTC SUMMARY
MALFUNCTION DESCRIPTION
If an overvoltage malfunction occurs in the motor inverter or generator inverter, the motor generator control ECU (MG ECU) detects the malfunction and stores this DTC. The cause of this malfunction may be one of the following:
Area | Main Malfunction Description |
|---|---|
Hybrid vehicle transaxle assembly |
|
Resolver |
Open or short circuit in the motor resolver or generator resolver circuit |
HV battery high-voltage line circuit |
|
Inverter |
|
DESCRIPTION
For a description of the boost converter.
Click here ![]()
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0E5717 |
DC/DC Converter Voltage Sensor "A"(VL) Circuit Voltage Above Threshold |
Boost converter overvoltage signal detected (overvoltage due to system malfunction): Overvoltage is detected before boosting. A malfunction is detected in any of the boost converter components (inverter, hybrid vehicle transaxle assembly, motor generator control ECU, etc.). (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0E5717 |
Emergency Shutdown Signal |
MONITOR DESCRIPTION
If the boost converter detects over-voltage, it transmits an over-voltage signal to the motor generator control ECU. Upon receiving this signal, the motor generator control ECU will illuminates the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs |
P0E57 (INF P0E5717): OVL detection (Over voltage malfunction) |
Required sensors/components |
Boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0E57 (INF P0E5717) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
- Depress the accelerator pedal of the vehicle with the engine stopped and shift lever in P to start the engine. [*3]
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
HINT:
[*1] to [*3]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Generator Resolver Circuit.
Click here ![]()
Refer to the wiring diagram for the Motor Resolver Circuit.
Click here ![]()
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the HV Battery High-voltage Line Circuit.
Click here ![]()
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0E5717 only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
System Main Relay or High Voltage Circuit Malfunction |
Hybrid control system |
P0AD911 |
Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
P0AD915 |
Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open |
||
P0ADD11 |
Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
||
P0ADD15 |
Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open |
||
P1C8449 |
High Voltage Power Resource Circuit Short during Ready ON |
||
HV Battery Malfunction |
Hybrid control system |
P0AFC16 |
Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |
P0AFC96 |
Hybrid/EV Battery Sensor Module Component Internal Failure |
||
P1CBE1E |
Hybrid/EV Battery Block 1 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CBF1E |
Hybrid/EV Battery Block 2 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC01E |
Hybrid/EV Battery Block 3 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC11E |
Hybrid/EV Battery Block 4 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC21E |
Hybrid/EV Battery Block 5 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC31E |
Hybrid/EV Battery Block 6 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC41E |
Hybrid/EV Battery Block 7 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC51E |
Hybrid/EV Battery Block 8 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC61E |
Hybrid/EV Battery Block 9 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC71E |
Hybrid/EV Battery Block 10 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CFD1E |
Hybrid/EV Battery Block 11 (Voltage Difference) Circuit Resistance Out of Range |
||
P301100 |
Hybrid/EV Battery Block 1 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301200 |
Hybrid/EV Battery Block 2 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301300 |
Hybrid/EV Battery Block 3 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301400 |
Hybrid/EV Battery Block 4 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301500 |
Hybrid/EV Battery Block 5 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301600 |
Hybrid/EV Battery Block 6 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301700 |
Hybrid/EV Battery Block 7 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301800 |
Hybrid/EV Battery Block 8 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301900 |
Hybrid/EV Battery Block 9 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P302000 |
Hybrid/EV Battery Block 10 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P302100 |
Hybrid/EV Battery Block 11 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
U029A87 |
Lost Communication with Hybrid/EV Battery Sensor Module Missing Message |
||
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
P0A1A49 |
Generator Control Module Internal Electronic Failure |
||
P0A1B1F |
Generator Control Module Circuit Intermittent |
||
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
||
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
||
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
||
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
||
P313383 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
||
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
||
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
||
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
||
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
||
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
||
Hybrid control system |
P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure |
|
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
Communication malfunction |
Motor generator control system |
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid control system |
P312387 |
Lost Communication with Missing Message |
|
Sensor and actuator circuit malfunction |
Motor generator control system |
P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A3F21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
||
P0A3F22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
||
P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
||
P0A4B21 |
Generator Position Sensor Signal Amplitude < Minimum |
||
P0A4B22 |
Generator Position Sensor Signal Amplitude > Maximum |
||
P0A6012 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
||
P0A6014 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
||
P0A601C |
Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
||
P0A6312 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
||
P0A6314 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
||
P0A631C |
Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
||
P0BE512 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
||
P0BE514 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
||
P0BE528 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BE912 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
||
P0BE914 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
||
P0BE928 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BED12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
||
P0BED14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
||
P0BED28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
||
P0C5013 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
||
P0C5016 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C5017 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C5A13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
||
P0C5A16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C5A17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0C6413 |
Generator Position Sensor Circuit "A" Circuit Open |
||
P0C6416 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C6417 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C6913 |
Generator Position Sensor Circuit "B" Circuit Open |
||
P0C6916 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C6917 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0D2D16 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
||
P0D2D17 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
||
P0DFA62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
||
P0E0012 |
Generator Phase U Current Sensor Circuit Short to Battery |
||
P0E0014 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
||
P0E0028 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0412 |
Generator Phase V Current Sensor Circuit Short to Battery |
||
P0E0414 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
||
P0E0428 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0812 |
Generator Phase W Current Sensor Circuit Short to Battery |
||
P0E0814 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
||
P0E0828 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E3116 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold |
||
P0E3117 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
||
P0E5111 |
DC/DC Converter Current Sensor Circuit Short to Ground |
||
P0E5115 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
||
P0E5128 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P1CAC49 |
Generator Position Sensor Internal Electronic Failure |
||
P1CAD49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
||
P1CAF38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
||
P1CB038 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
||
P1CFF62 |
Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
||
Hybrid control system |
P0C7600 |
Hybrid/EV Battery System Discharge Time Too Long |
|
P0D2D1C |
Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range |
||
P0E311C |
Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range |
||
System malfunction |
Motor generator control system |
P0A9000 |
Drive Motor "A" Performance |
P0A9200 |
Hybrid Generator Performance |
||
P0BFF1D |
Drive Motor "A" Circuit Current Out of Range |
||
P0C1900 |
Drive Motor "A" Execution Torque Performance |
||
P0CA300 |
DC/DC Converter Step Up Voltage Performance |
||
P0E7100 |
Generator Execution Torque Performance |
||
P1CA51D |
Hybrid Generator Circuit Current Out of Range |
||
P314F1F |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
||
P31531D |
DC/DC Converter Current Sensor Circuit Current Out of Range |
||
Hybrid control system |
P0A9300 |
Inverter "A" Cooling System |
|
P0AA649 |
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
||
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
||
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
||
Relevant DTC |
|
|---|---|
P0A3F1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
P0A4B1F |
Generator Position Sensor Circuit Intermittent |
P0A601F |
Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
P0A631F |
Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
P0C501F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
P0C5A1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
P0C641F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
P0C691F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
P0D2D1F |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
P0E311F |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
P1C601F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
P1C621F |
Generator Control Module Offset Power Circuit Intermittent |
P1C641F |
Generator Control Module Circuit Intermittent |
P1C651F |
Generator Control Module Circuit Intermittent |
P1C671F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
P1C691F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
P31241F |
Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
HINT:
- P0E5717 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.
Powertrain > Motor Generator > UtilityDiagnosis Related Information
(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Powertrain > Motor Generator > Trouble Codes(e) Read the freeze frame data of DTC P0E5717.
Result | Proceed to |
|---|---|
DTC P312487 is listed in Diagnosis Related Information. |
A |
DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. |
B |
Other than above |
C |
(f) Turn the power switch off.
| A | GO TO DTC CHART (P312487) |
| B | GO TO DTC CHART (P321E9F) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK GENERATOR RESOLVER CIRCUIT
Click here ![]()
|
CHECK MOTOR RESOLVER CIRCUIT
Click here ![]()
|
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
|
CHECK HV BATTERY HIGH-VOLTAGE LINE CIRCUIT
Click here ![]()
|
CHECK INVERTER LOW-VOLTAGE CIRCUIT
Click here ![]()
HINT:
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
DC/DC Converter Temperature Sensor 2 Circuit Short to Ground (P0E5811,P0E5815)
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into in the inverter with converter assembly, detects the temperature of the boost converter using the boost converter temperature sensor 2 (lower). The motor generator control ECU (MG ECU) also detects malfunctions in the boost converter temperature sensor 2 (lower) and its wiring.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0E5811 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Ground |
Short to ground detected in boost converter temperature sensor 2 (lower) circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
P0E5815 |
DC/DC Converter Temperature Sensor 2 Circuit Short to Battery or Open |
Open or short to +B detected in boost converter temperature sensor 2 (lower) circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0E5811 P0E5815 |
Boosting Converter Temperature 2 (Lower) |
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the boost converter temperature sensor 2 (lower), it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0E5A (INF P0E5811): DC/DC Converter Temperature Sensor "C" Range Check P0E5B (INF P0E5815): DC/DC Converter Temperature Sensor "C" Range Check |
Required sensors/components |
Boost converter temperature sensor 2 (lower) |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
Immediately |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0E5A (INF P0E5811) is not detected DTC P0E5B (INF P0E5815) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
PROCEDURE
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
| NEXT | COMPLETED |