Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range (P0A001C). Generator Control Module Circuit Intermittent (P0A1B1F). Drive Motor "A" Position Sensor Circuit Voltage Below Thre
Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range (P0A001C)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the temperature sensor value is abnormal. The cause of this malfunction may be one of the following:
Area | Main Malfunction Description | Step |
|---|---|---|
| Inverter low-voltage circuit | The connectors are not connected properly |
2 |
Hybrid cooling system |
Coolant circulation abnormal (frozen or leaking, etc.) |
3 |
| Inside of inverter | Inverter with converter assembly internal circuit malfunction |
3 |
DESCRIPTION
The motor generator control ECU detects the HV coolant temperature using the HV coolant temperature sensor built into the inverter with converter assembly. The motor generator control ECU uses signals from the coolant temperature sensor to check the effectiveness of the inverter cooling system. If necessary, the motor generator control ECU will limit inverter output to help prevent inverter overheating. The motor generator control ECU also detects malfunctions in the sensor based on the HV coolant temperature sensor values.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0A001C |
Motor Electronics Coolant Temperature Sensor Circuit Voltage Out of Range |
The actual inverter coolant temperature is high and the difference between the estimated inverter coolant temperature and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the inverter coolant temperature sensor value differs from the values of other sensors. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0A001C |
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the Motor Electronics Coolant Temperature Sensor, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0A01 (INF P0A001C): Motor Electronics Coolant Temperature Sensor Circuit Range / Performance |
Required sensors/components |
Inverter, boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0A01 (INF P0A001C) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 5 hours or more. [*1]
NOTICE:
Make sure that the temperature of the motor and generator do not drop below -10°C (14°F).
- Turn the power switch on (IG) and within 3 seconds or less, turn the power switch on (READY) and wait 10 seconds or more. [*2]
HINT:
It is possible to turn the power switch on (READY) without turning it on (IG) first.
- Turn the Techstream on. [*3]
- Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25 °C or more. [*4]
HINT:
[*1] to [*4]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Cooling System.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble CodesResult | Proceed to |
|---|---|
P0A001C only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Malfunction Content | Relevant DTC |
|
|---|---|---|
Insulation Malfunction |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
|
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
|
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
|
Malfunction Content | Relevant DTC |
|
|---|---|---|
Sensor and actuator circuit malfunction |
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
|
System malfunction |
P0A9300 |
Inverter "A" Cooling System |
HINT:
- P0A001C may be output as a result of the malfunctions indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK COOLING SYSTEM
Click here ![]()
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Generator Control Module Circuit Intermittent (P0A1B1F)
DESCRIPTION
If the motor generator control ECU, which is built into in the inverter with converter assembly, is reset due to a problem with the power source in the inverter, the motor generator control ECU will store this DTC.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0A1B1F |
Generator Control Module Circuit Intermittent |
Error in reset signal from the inverter assembly power source IC: If internal power source voltage drops below the normal CPU operating voltage or the ROM/RAM is malfunctioning, the power source IC resets the MG ECU and stores this DTC. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
MONITOR DESCRIPTION
The motor generator control ECU monitors its internal operation and will illuminate the MIL and store a DTC if it detects a malfunction.
MONITOR STRATEGY
Related DTCs |
P0A1B (INF P0A1B1F): Drive Motor "A" Control Module |
Required sensors/components |
Motor generator control ECU |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
Immediately |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0A1B (INF P0A1B1F) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 15 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0A1B1F only is output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Communication malfunction |
Motor generator control system |
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid control system |
P312387 |
Lost Communication with Missing Message |
|
U011087 |
Lost Communication with Drive Motor Control Module "A" Missing Message |
||
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT RELAY)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Disconnect the A42 inverter with converter assembly connector.
(c) Remove the IGCT relay from the instrument panel relay block.
(d) Measure the resistance according to the value(s) in the table below.
*1 |
Instrument Panel Relay Block |
*2 |
IGCT Relay |
*a |
Front view of wire harness connector (to Inverter with Converter Assembly) |
- |
- |
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
A42-6 (+B) - 5 (IGCT relay) |
Power switch off |
Below 1 Ω |
A42-5 (+B2) - 5 (IGCT relay) |
Power switch off |
Below 1 Ω |
A42-24 (GND1) - Body ground |
Power switch off |
Below 1 Ω |
A42-23 (GND2) - Body ground |
Power switch off |
Below 1 Ω |
(e) Install the IGCT relay.
(f) Reconnect the A42 inverter with converter assembly connector.
| OK | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold (P0A3F16,P0A3F1F)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the resolver output signal is abnormal. The cause of this malfunction may be one of the following:
Area | Main Malfunction Description |
|---|---|
Inverter low-voltage circuit |
The connectors are not connected properly |
Hybrid Vehicle Transaxle Assembly |
|
Wire harness between the resolver and inverter with converter assembly |
|
Inside of inverter |
Inverter with converter assembly internal circuit malfunction |
DESCRIPTION
Refer to the system description for the Motor Resolver Circuit.
Click here ![]()
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
Interphase short in the motor resolver circuit: A short circuit between signal lines of motor resolver phases is electrically detected. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P0A3F1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
A short circuit between signal lines of motor resolver phases is electrically detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
|
Does not come on |
Master Warning Light: Does not come on |
MONITOR DESCRIPTION
The motor generator control ECU monitors the motor resolver output signal. If the motor generator control ECU detects output signals that are out of the normal range or specification, it will conclude that there is a malfunction in the motor resolver, illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0A3F (INF P0A3F16): Circuit Voltage Below Threshold |
Required sensors/components |
Motor resolver |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0A3F (INF P0A3F16) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
- Depress the accelerator pedal of the vehicle with the engine stopped and shift lever in P to start the engine. [*3]
- Drive the vehicle forward with the shift lever in D for 5 m (16 ft.) or more. [*4]
- Drive the vehicle backward with the shift lever in R for 5 m (16 ft.) or more. [*5]
HINT:
[*1] to [*5]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Motor Resolver Circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
HINT:
- If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
- If the resolver is malfunctioning, the vehicle may not drive smoothly.
- When inspecting the connectors, if it is difficult to judge if a connector was disconnected, deformed or improperly secured, disconnect and reconnect the connector and then check for DTCs again. Check if the same DTC is output. If the same DTC is not output, improper connection of connectors is suspected.
- As a malfunction detection threshold may be exceeded when performing the vibration or heat connector inspections, make sure to perform the following inspection to check that the DTC was not stored due to the malfunction of a part.
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0A3F16 or P0A3F1F only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
HINT:
- P0A3F16 or P0A3F1F may be output as a result of the malfunctions indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK MOTOR RESOLVER CIRCUIT
Click here ![]()
HINT:
If the "Motor Resolver Circuit" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |