Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range (P0AED1C). Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground (P0AED11,P0AED15). Drive Motor "A" Phase U-V-W C
Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range (P0AED1C)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the motor inverter temperature sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction- Inverter with converter assembly internal circuit malfunction
- Coolant circulation abnormal (frozen or leaking, etc.)
- The connectors are not connected properly
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into in the inverter with converter assembly, detects the temperature of the motor inverter using the motor inverter temperature sensor. If necessary, the motor generator control ECU (MG ECU) will limit inverter output to help prevent the motor inverter from overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0AED1C |
Drive Motor Inverter Temperature Sensor "A" Circuit Voltage Out of Range |
The actual motor inverter temperature high and the difference between the estimated motor inverter temperature and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the motor inverter temperature sensor value differs from the values of other sensors. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0AED1C |
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the Drive Motor Inverter Temperature Sensor "A", it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0AEE (INF P0AED1C): Drive Motor Inverter Temperature Sensor "A" Circuit Range / Performance |
Required sensors/components |
Inverter, boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0AEE (INF P0AED1C) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch on (READY), shift lever in D, while depressing the brake pedal with the vehicle stopped, depress the accelerator pedal. [*1]
- After the engine starts, release the accelerator pedal and wait for the engine to stop. [*2]
- Turn the power switch off and wait for 5 hours or more. [*3]
NOTICE:
Make sure that the temperature of the inverter coolant do not drop below 15 °C.
- Turn the power switch on (IG) and within 3 seconds or less, turn the power switch on (READY) and wait 10 seconds or more. [*4]
HINT:
It is possible to turn the power switch on (READY) without turning it on (IG) first.
- Turn the Techstream on. [*5]
- Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25 °C or more. [*6]
HINT:
[*1] to [*6]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Cooling System.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble CodesResult | Proceed to |
|---|---|
P0AED1C only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Malfunction Content | Relevant DTC |
|
|---|---|---|
Insulation Malfunction |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
|
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
|
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
|
Malfunction Content | Relevant DTC |
|
|---|---|---|
Sensor and actuator circuit malfunction |
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
|
System malfunction |
P0A9300 |
Inverter "A" Cooling System |
HINT:
- P0AED1C may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK COOLING SYSTEM
Click here ![]()
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground (P0AED11,P0AED15)
DESCRIPTION
The motor generator control ECU (MG ECU), which is built into in the inverter with converter assembly, detects the temperature of the motor inverter using the motor inverter temperature sensor. The inverter cooling system operates independently of the engine cooling system. The motor generator control ECU (MG ECU) uses signals from the motor inverter temperature sensor to check the effectiveness of the inverter cooling system. If necessary, the motor generator control ECU (MG ECU) will limit inverter output to help prevent inverter overheating. The motor generator control ECU (MG ECU) also detects malfunctions in the motor inverter temperature sensor and its wiring.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0AED11 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Ground |
Short to ground detected in motor inverter temperature sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
P0AED15 |
Drive Motor Inverter Temperature Sensor "A" Circuit Short to Battery or Open |
Open or short to +B detected in motor inverter temperature sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0AED11 P0AED15 |
Motor Inverter Temperature |
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the motor inverter temperature sensor, it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0AEF (INF P0AED11): Drive Motor Inverter Temperature Sensor "A" P0AF0 (INF P0AED15): Drive Motor Inverter Temperature Sensor "A" |
Required sensors/components |
Motor inverter temperature sensor |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
Immediately |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0AEF (INF P0AED11) is not detected DTC P0AF0 (INF P0AED15) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
PROCEDURE
REPLACE INVERTER WITH CONVERTER ASSEMBLY
Click here ![]()
| NEXT | COMPLETED |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure (P0BFD62,P1C671F)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction- Current sensor malfunction
- Inverter with converter assembly internal circuit malfunction
DESCRIPTION
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
Motor inverter current sensor characteristic malfunction: The value of the total output of the U, V and W phase current sensors exceeds the threshold.*1 (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P1C671F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
The value of the total output of the U, V and W phase current sensors exceeds the threshold detected when DTC P0C7917, P0D3319, P1C5D19 or P1C5F19 is stored. (1 trip detection logic) |
|
Does not come on |
Master Warning Light: Does not come on |
HINT:
*1: Under normal conditions, the value of the total output of the U, V and W phase current sensors is approximately 0.
MONITOR DESCRIPTION
If the value of the total output of the U, V and W phase current sensors exceeds a threshold, a malfunction will be detected, the motor generator control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0BFD (INF P0BFD62): Drive Motor "A" Phase U-V-W Current Sensor Correlation |
Required sensors/components |
Motor inverter phase U current sensor Motor inverter phase V current sensor Motor inverter phase W current sensor |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0BFD (INF P0BFD62) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) with the shift lever in P and wait for 5 seconds or more. [*2]
- Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine. [*3]
- Drive the vehicle for approximately 10 minutes referring to the following freeze frame data items: "Vehicle Speed". [*4]
HINT:
[*1] to [*4]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0BFD62 or P1C671F only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the table below are output. |
B |
DTCs of motor generator control system in the table below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
High voltage system malfunction |
Hybrid control system |
P0AA649 |
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Microcomputer malfunction |
Hybrid control system |
P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure |
Motor generator control system |
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
|
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
||
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
||
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
System malfunction |
Motor generator control system |
P0A7873 |
Drive Motor "A" Inverter Actuator Stuck Closed |
HINT:
- P0BFD62 or P1C671F may be output as a result of the malfunctions indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
HINT:
If the "Motor High-voltage Circuit" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |