DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range (P0C3D1C). DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range (P0C381C). Drive Motor "A" Execution Torque Performan
DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range (P0C3D1C)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the boost converter temperature sensor (lower) value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction- Inverter with converter assembly internal circuit malfunction
- Coolant circulation abnormal (frozen or leaking, etc.)
- The connectors are not connected properly
DESCRIPTION
The motor generator control ECU, which is built into in the inverter with converter assembly, detects the temperature of the boost converter using a temperature sensor built into the boost converter. If necessary, the motor generator control ECU will limit inverter output to help prevent the boost converter from overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0C3D1C |
DC/DC Converter Temperature Sensor "B" Circuit Voltage Out of Range |
The actual boost converter temperature (lower) high and the difference between the estimated boost converter temperature (lower) and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the boost converter temperature (lower) sensor value differs from the values of other sensors. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0C3D1C |
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the DC/DC Converter Temperature Sensor "B" , it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0C3E (INF P0C3D1C): DC/DC Converter Temperature Sensor "B" Range / Performance |
Required sensors/components |
Inverter, boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0C3E (INF P0C3D1C) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch on (READY), shift lever in D, while depressing the brake pedal with the vehicle stopped, depress the accelerator pedal. [*1]
- After the engine starts, release the accelerator pedal and wait for the engine to stop. [*2]
- Turn the power switch off and wait for 5 hours or more. [*3]
NOTICE:
Make sure that the temperature of the inverter coolant do not drop below 15 °C.
- Turn the power switch on (IG) and within 3 seconds or less, turn the power switch on (READY) and wait 10 seconds or more. [*4]
HINT:
It is possible to turn the power switch on (READY) without turning it on (IG) first.
- Turn the Techstream on. [*5]
- Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25 °C or more. [*6]
HINT:
[*1] to [*6]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Cooling System.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble CodesResult | Proceed to |
|---|---|
P0C3D1C only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Malfunction Content | Relevant DTC |
|
|---|---|---|
Insulation Malfunction |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
|
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
|
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
|
Malfunction Content | Relevant DTC |
|
|---|---|---|
Sensor and actuator circuit malfunction |
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
|
System malfunction |
P0A9300 |
Inverter "A" Cooling System |
HINT:
P0C3D1C may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK COOLING SYSTEM
Click here ![]()
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range (P0C381C)
DTC SUMMARY
MALFUNCTION DESCRIPTION
These DTCs indicate that the boost converter temperature sensor (upper) value is abnormal. The cause of this malfunction may be one of the following:
Internal inverter malfunction- Inverter with converter assembly internal circuit malfunction
- Coolant circulation abnormal (frozen or leaking, etc.)
- The connectors are not connected properly
DESCRIPTION
The motor generator control ECU, which is built into in the inverter with converter assembly, detects the temperature of the boost converter using the temperature sensor built into the boost converter. If necessary, the motor generator control ECU will limit inverter output to help prevent boost converter overheating. The motor generator control ECU also detects malfunctions in the sensor based on the temperature sensor values.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0C381C |
DC/DC Converter Temperature Sensor "A" Circuit Voltage Out of Range |
The actual boost converter temperature (upper) high and the difference between the estimated boost converter temperature (upper) and the actual temperature exceeds a threshold for 10 seconds, or after a long soak, the boost converter temperature (upper) sensor value differs from the values of other sensors. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0C381C |
|
MONITOR DESCRIPTION
If the motor generator control ECU detects a malfunction of the DC/DC Converter Temperature sensor "A", it will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0C39 (INF P0C381C): DC/DC Converter Temperature Sensor "A" Range / Performance |
Required sensors/components |
Inverter, boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0C39 (INF P0C381C) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch on (READY), shift lever in D, while depressing the brake pedal with the vehicle stopped, depress the accelerator pedal. [*1]
- After the engine starts, release the accelerator pedal and wait for the engine to stop. [*2]
- Turn the power switch off and wait for 5 hours or more. [*3]
NOTICE:
Make sure that the temperature of the inverter coolant do not drop below 15 °C.
- Turn the power switch on (IG) and within 3 seconds or less, turn the power switch on (READY) and wait 10 seconds or more. [*4]
HINT:
It is possible to turn the power switch on (READY) without turning it on (IG) first.
- Turn the Techstream on. [*5]
- Drive the vehicle for approximately 10 minutes with the value of Data List item "Inverter Coolant Temperature" 25 °C or more. [*6]
HINT:
[*1] to [*6]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Cooling System.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble CodesResult | Proceed to |
|---|---|
P0C381C only is output, or DTCs except the ones in the table below are also output. |
A |
Any of the following DTCs are also output. |
B |
Malfunction Content | Relevant DTC |
|
|---|---|---|
Insulation Malfunction |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
|
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
|
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
|
Malfunction Content | Relevant DTC |
|
|---|---|---|
Sensor and actuator circuit malfunction |
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
|
System malfunction |
P0A9300 |
Inverter "A" Cooling System |
HINT:
- P0C381C may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK COOLING SYSTEM
Click here ![]()
HINT:
If the "Cooling System" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
Drive Motor "A" Execution Torque Performance (P0C1900)
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that the motor torque execution value does not correspond to the torque command value sent from the hybrid vehicle control ECU to the motor (MG2). The cause of this malfunction may be one of the following:
Area | Main Malfunction Description |
|---|---|
Inside of inverter |
Inverter with converter assembly internal circuit malfunction |
Hybrid vehicle transaxle assembly |
|
Motor cable (for MG2) |
|
Inverter low-voltage circuit |
The connectors are not connected properly |
Hybrid vehicle control ECU |
Hybrid vehicle control ECU internal circuit malfunction |
DESCRIPTION
For a description of the inverter.
Click here ![]()
A DTC is stored when the actual motor torque deviates from the motor torque requested by the hybrid vehicle control ECU.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0C1900 |
Drive Motor "A" Execution Torque Performance |
Motor (MG2) torque execution monitoring malfunction: The difference between the motor torque requested by the motor generator control ECU and actual motor torque is large. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0C1900 |
|
MONITOR DESCRIPTION
If the difference between the requested motor torque and the actual motor (MG2) torque exceeds a predetermined value, the motor generator control ECU determines that there is a malfunction in the execution or monitoring of the motor (MG2) torque. Then, the motor generator control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0C19 (INF P0C1900): Discrepancy between motor monitored torque and commanded torque |
Required sensors/components |
Motor inverter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
P0C19 (INF P0C1900) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- Turn the power switch on (READY) and wait for 5 seconds or more. [*1]
HINT:
Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
- Drive the vehicle for approximately 10 minutes referring to the following freeze frame data items: "Vehicle Speed". [*2]
HINT:
[*1] to [*2]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the Shut Down Signal Circuit.
Click here ![]()
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0C1900 only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
System Main Relay or High Voltage Circuit Malfunction |
Hybrid control system |
P0AD911 |
Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
P0AD915 |
Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open |
||
P0ADD11 |
Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
||
P0ADD15 |
Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open |
||
P1C8449 |
High Voltage Power Resource Circuit Short during Ready ON |
||
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
P0A1A49 |
Generator Control Module Internal Electronic Failure |
||
P0A1B1F |
Generator Control Module Circuit Intermittent |
||
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
||
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
||
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
||
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
||
P313383 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
||
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
||
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
||
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
||
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
||
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
||
Hybrid control system |
P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure |
|
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
Sensor and actuator circuit malfunction |
Motor generator control system |
P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A3F21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
||
P0A3F22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
||
P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
||
P0A4B21 |
Generator Position Sensor Signal Amplitude < Minimum |
||
P0A4B22 |
Generator Position Sensor Signal Amplitude > Maximum |
||
P0A6012 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
||
P0A6014 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
||
P0A601C |
Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
||
P0A6312 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
||
P0A6314 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
||
P0A631C |
Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
||
P0BE512 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
||
P0BE514 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
||
P0BE528 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BE912 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
||
P0BE914 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
||
P0BE928 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BED12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
||
P0BED14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
||
P0BED28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
||
P0C5013 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
||
P0C5016 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C5017 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C5A13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
||
P0C5A16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C5A17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0C6413 |
Generator Position Sensor Circuit "A" Circuit Open |
||
P0C6416 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C6417 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C6913 |
Generator Position Sensor Circuit "B" Circuit Open |
||
P0C6916 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C6917 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0D2D16 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
||
P0D2D17 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
||
P0DFA62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
||
P0E0012 |
Generator Phase U Current Sensor Circuit Short to Battery |
||
P0E0014 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
||
P0E0028 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0412 |
Generator Phase V Current Sensor Circuit Short to Battery |
||
P0E0414 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
||
P0E0428 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0812 |
Generator Phase W Current Sensor Circuit Short to Battery |
||
P0E0814 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
||
P0E0828 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E3116 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold |
||
P0E3117 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
||
P0E5111 |
DC/DC Converter Current Sensor Circuit Short to Ground |
||
P0E5115 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
||
P0E512A |
DC/DC Converter Current Sensor Signal Stuck In Range |
||
P1CAC49 |
Generator Position Sensor Internal Electronic Failure |
||
P1CAD49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
||
P1CAF38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
||
P1CB038 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
||
Hybrid control system |
P0C7600 |
Hybrid/EV Battery System Discharge Time Too Long |
|
P0D2D1C |
Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range |
||
P0E311C |
Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range |
||
P1C2D62 |
Drive Motor "A" Inverter before Boosting Voltage Sensor Signal Compare Failure |
||
System malfunction |
Motor generator control system |
P0A7873 |
Drive Motor "A" Inverter Actuator Stuck Closed |
P0A7A73 |
Generator Inverter Actuator Stuck Closed |
||
P0A9200 |
Hybrid Generator Performance |
||
P1C5F19 |
Generator Inverter Circuit Current Above Threshold |
||
HINT:
- P0C1900 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.
Powertrain > Motor Generator > UtilityDiagnosis Related Information
(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Powertrain > Motor Generator > Trouble Codes(e) Read the diagnosis related information and freeze frame data of DTC P0C1900.
Result | Proceed to |
|---|---|
DTC P312487 is listed in Diagnosis Related Information. |
A |
DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. |
B |
Other than above |
C |
(f) Turn the power switch off.
| A | GO TO DTC CHART (P312487) |
| B | GO TO DTC CHART (P321E9F) |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK SHUT DOWN SIGNAL CIRCUIT
Click here ![]()
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
|
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
HINT:
If the "Generator High-voltage Circuit" inspection results are normal, perform the next step.
| NEXT | REPLACE INVERTER WITH CONVERTER ASSEMBLY |