Fuse Box
Components
COMPONENTS
ILLUSTRATION
*1 |
NO. 1 HV BATTERY SHIELD PANEL |
*2 |
UPPER HV BATTERY COVER SUB-ASSEMBLY |
*3 |
HYBRID BATTERY TERMINAL BLOCK |
- |
- |
![]() |
N*m (kgf*cm, ft.*lbf): Specified torque |
- |
- |
Inspection
INSPECTION
PROCEDURE
1. INSPECT HYBRID BATTERY TERMINAL BLOCK
(a) Measure the resistance according to the value(s) in the table below. Standard Resistance:
If the result is not as specified, replace the hybrid battery terminal block. |
![]() |
Installation
INSTALLATION
PROCEDURE
1. INSTALL HYBRID BATTERY TERMINAL BLOCK
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Connect the 2 hybrid battery terminal block connectors.
NOTICE:
Make sure that the connectors are connected securely.
(b) Install the hybrid battery terminal block to the HV battery with the bolt. Torque: 7,5 N·m {76 kgf·cm, 66 in·lbf} NOTICE: Make sure to align the hole of the hybrid battery terminal block with the pin. |
|
2. INSTALL NO. 1 HV BATTERY SHIELD PANEL
Click here ![]()
3. INSTALL UPPER HV BATTERY COVER SUB-ASSEMBLY
Click here ![]()
4. INSTALL HV BATTERY
Click here ![]()
Removal
REMOVAL
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during hybrid battery terminal block removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/ReplacedReplaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
| *: When performing learning using the Techstream. Click here |
|||
Auxiliary battery terminal is disconnected/reconnected |
Perform steering sensor zero point calibration |
Lane departure alert system (w/ Steering Control) |
|
Pre-collision system |
|||
Intelligent clearance sonar system* |
|||
Lighting System (for HV Model with Cornering Light) |
|||
Memorize steering angle neutral point |
Parking assist monitor system |
||
Panoramic view monitor system |
|||
Replacement of hybrid battery terminal block |
High voltage fuse accumulated load history reset |
DTCs are stored |
|
CAUTION:
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click here

- To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
1. REMOVE HV BATTERY
Click here ![]()
2. REMOVE UPPER HV BATTERY COVER SUB-ASSEMBLY
Click here ![]()
3. REMOVE NO. 1 HV BATTERY SHIELD PANEL
Click here ![]()
4. REMOVE HYBRID BATTERY TERMINAL BLOCK
CAUTION:
Be sure to wear insulated gloves and protective goggles.
(a) Remove the bolt to separate the hybrid battery terminal block from the HV battery. |
![]() |
(b) Disconnect the 2 hybrid battery terminal block connectors to remove the hybrid battery terminal block. NOTICE: Insulate the disconnected high-voltage connectors with insulating tape. |
![]() |