Inverter With Converter
Components
COMPONENTS
ILLUSTRATION
*1 |
BATTERY SERVICE HOLE COVER |
*2 |
SERVICE PLUG GRIP |
ILLUSTRATION
*1 |
NO. 1 ENGINE COVER SUB-ASSEMBLY |
*2 |
INLET AIR CLEANER ASSEMBLY |
*3 |
AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE |
*4 |
COOL AIR INTAKE DUCT SEAL |
*5 |
NO. 1 ENGINE UNDER COVER |
- |
- |
![]() |
N*m (kgf*cm, ft.*lbf): Specified torque |
- |
- |
ILLUSTRATION
*1 |
NO. 1 FUEL VAPOR FEED HOSE |
*2 |
NO. 2 FUEL VAPOR FEED HOSE |
*3 |
ENGINE WIRE |
*4 |
ENGINE ROOM MAIN WIRE |
*5 |
HV AIR CONDITIONING WIRE |
*6 |
CONNECTOR COVER ASSEMBLY |
*7 |
HV FLOOR UNDER WIRE |
*8 |
NO. 1 INVERTER COOLING HOSE |
*9 |
NO. 4 INVERTER COOLING HOSE |
*10 |
WIRE HARNESS CLAMP BRACKET |
*11 |
INVERTER WITH CONVERTER ASSEMBLY |
*12 |
TRANSMISSION CONTROL CABLE ASSEMBLY |
*13 |
MOTOR CABLE |
*14 |
INVERTER COVER |
![]() |
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf) |
![]() |
N*m (kgf*cm, ft.*lbf): Specified torque |
● |
Non-reusable part |
- |
- |
ILLUSTRATION
*1 |
WIRE HARNESS CLAMP BRACKET |
*2 |
INVERTER WITH CONVERTER ASSEMBLY |
*3 |
NO. 1 INVERTER BRACKET |
*4 |
NO. 2 INVERTER BRACKET |
*5 |
INVERTER PROTECTOR |
- |
- |
![]() |
N*m (kgf*cm, ft.*lbf): Specified torque |
- |
- |
Installation
INSTALLATION
PROCEDURE
1. INSTALL INVERTER PROTECTOR
(a) Install the inverter protector to the inverter with converter assembly with the bolt. Torque: 9,5 N·m {97 kgf·cm, 84 in·lbf} NOTICE: Make sure to align the hole of the inverter protector with the pin. |
|
2. INSTALL WIRE HARNESS CLAMP BRACKET
(a) Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(b) Install the wire harness clamp bracket to the inverter with converter assembly with the bolt.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(c) Install the 2 wire harness clamp brackets to the inverter with converter assembly with the 2 bolts.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
3. INSTALL NO. 2 INVERTER BRACKET
NOTICE:
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
*a |
Bottom of Inverter with Converter Assembly |
*b |
Support |
(a) Set the inverter with converter assembly on wooden blocks. |
|
(b) Temporarily install the No. 2 inverter bracket to the inverter with converter assembly with the 2 bolts.
(c) Fully tighten the 2 bolts in the order shown in the illustration.
Torque:
15 N·m {153 kgf·cm, 11 ft·lbf}
4. INSTALL NO. 1 INVERTER BRACKET
(a) Temporarily install the No. 1 inverter bracket to the inverter with converter assembly with the 2 bolts. |
|
(b) Fully tighten the 2 bolts in the order shown in the illustration.
Torque:
15 N·m {153 kgf·cm, 11 ft·lbf}
5. INSTALL INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
(a) Temporarily install the inverter with converter assembly with the 5 bolts and 2 nuts.
NOTICE:
- When installing the inverter with converter assembly, be careful not to damage the parts around it.
- To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
- To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
- Make sure that the inverter with converter assembly is positioned so that the stud bolts are in contact with the base of the U-shaped portions of the No. 1 inverter bracket.
*a
Correct
*b
Incorrect
HINT:
If the bolts and nuts are not tightened appropriately, the inverter with converter assembly may make an abnormal noise.
(b) Fully tighten the bolt (A).
Torque:
55 N·m {561 kgf·cm, 41 ft·lbf}
(c) Fully tighten the 3 bolts (B).
Torque:
55 N·m {561 kgf·cm, 41 ft·lbf}
(d) Fully tighten the bolt (C).
Torque:
55 N·m {561 kgf·cm, 41 ft·lbf}
(e) Fully tighten the 2 nuts (D).
Torque:
55 N·m {561 kgf·cm, 41 ft·lbf}
6. CONNECT MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
(a) Temporarily connect the motor cable to the inverter with converter assembly with the 4 bolts.
NOTICE:
- Do not touch the waterproof seal or terminals of the motor cable.
- Do not damage the terminals, connector housing or inverter with converter assembly during connection.
(b) Fully tighten the bolt (A). Torque: 8 N·m {82 kgf·cm, 71 in·lbf} |
|
(c) Fully tighten the 3 bolts in the order shown in the illustration to connect the motor cable to the inverter with converter assembly.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
(d) Temporarily install the 6 bolts. NOTICE:
|
![]() |
(e) Using an insulated tool, fully tighten the 6 bolts.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
NOTICE:
- Do not touch the waterproof seal or terminals of the motor cable.
- Do not damage the terminals, connector housing or inverter with converter assembly during connection.
- Be sure to use a torque wrench to tighten the bolts.
7. INSTALL INVERTER COVER
CAUTION:
Be sure to wear insulated gloves.
(a) Install the inverter cover to the inverter with converter assembly with the 2 bolts.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
NOTICE:
- Visually confirm that the inverter cover waterproof seal is securely installed before installing the inverter cover.
- Do not touch the waterproof seal of the inverter cover.
- Make sure that the interlock is fully engaged.
- Do not damage the terminals, interlock connector or inverter with converter assembly during installation.
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
- Do not remove or excessively tighten the screw of the inverter cover.
*1
Inverter Cover
*a
Screw
- Although the inverter cover may feel loose, this is not due to a malfunction.
- Push in the inverter cover until it contacts the inverter with converter assembly.
*a
No Gap
8. CONNECT NO. 4 INVERTER COOLING HOSE
(a) Connect the No. 4 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it. NOTICE:
HINT: Make sure that the clip is positioned as shown in the illustration. |
|
9. CONNECT NO. 1 INVERTER COOLING HOSE
(a) Connect the No. 1 inverter cooling hose to the inverter with converter assembly and slide the clip to secure it. NOTICE:
HINT: Make sure that the clip is positioned as shown in the illustration. |
|
10. CONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
(a) Connect the transmission control cable assembly to the inverter with converter assembly with the 3 bolts.
Torque:
12 N·m {122 kgf·cm, 9 ft·lbf}
(b) Turn the control shaft lever clockwise until it stops, then turn it counterclockwise 2 notches. |
![]() |
(c) Engage the 2 claws to install a new clip to the transmission control cable assembly.
(d) Using a screwdriver, engage the 4 claws and install the transmission control cable assembly to the No. 1 transmission control cable bracket. NOTICE:
|
|
(e) Connect the transmission control cable assembly to the control shaft lever with the nut.
Torque:
12 N·m {122 kgf·cm, 9 ft·lbf}
11. CONNECT ENGINE WIRE
CAUTION:
Be sure to wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
(a) Engage the 2 clamps and connect the engine wire to the inverter with converter assembly. |
![]() |
(b) Temporarily install the nut.
NOTICE:
To prevent the threads from being damaged, temporarily tighten the nut by hand.
(c) Fully tighten the nut.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(d) Engage the 2 claws to close the engine wire terminal cover.
(e) Connect the engine wire to the inverter with converter assembly with the bolt. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
![]() |
(f) Connect the engine wire to the inverter with converter assembly with the bolt. Torque: 10 N·m {102 kgf·cm, 7 ft·lbf} |
![]() |
(g) Engage the 2 clamps.
(h) Engage the clamp.
(i) Connect the shift lever position sensor connector.
(j) Connect the resolver (transmission fluid temperature sensor) connector.
(k) Connect the generator temperature sensor connector.
(l) Engage the clamp (B). |
![]() |
(m) Connect the engine wire to the intake manifold with the bolt.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(n) Engage the 2 clamps (A) and connect the No. 1 fuel vapor feed hose and No. 2 fuel vapor feed hose.
(o) Engage the 2 clamps (B). |
![]() |
(p) Connect the engine wire to the inverter with converter assembly with the bolt.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(q) Engage the 3 clamps (A) and connect the No. 1 fuel vapor feed hose.
(r) Connect the inverter with converter assembly connector and move the lock lever to lock them. NOTICE:
|
![]() |
12. INSTALL WIRE HARNESS CLAMP BRACKET
(a) Install the wire harness clamp bracket to the inverter with converter assembly with the nut.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
13. CONNECT HV AIR CONDITIONING WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Engage the clamp and connect the HV air conditioning wire to the inverter with converter assembly. NOTICE:
|
|
(b) Install the 2 bolts.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
14. CONNECT HV FLOOR UNDER WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Engage the 2 clamps and connect the HV floor under wire to the inverter with converter assembly. NOTICE:
|
|
(b) Install the 2 bolts.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
15. CONNECT ENGINE ROOM MAIN WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Engage the clamp to connect the engine room main wire to the inverter with converter assembly.
(b) Install the bolt.
Torque:
10 N·m {102 kgf·cm, 7 ft·lbf}
(c) Connect the inverter with converter assembly connector and move the lock lever to lock them. NOTICE:
|
![]() |
16. INSTALL ECM
Click here ![]()
17. INSTALL AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE
(a) Install the air cleaner cap with air cleaner hose to the throttle body with motor assembly. NOTICE: Align the cutout of the air cleaner hose assembly with the protrusion of the throttle body with motor assembly. |
|
(b) Tighten the hose clamp in the position shown in the illustration.
NOTICE:
Make sure that the end of the hose clamp is positioned as shown in the illustration.
(c) Connect the No. 2 ventilation hose to the cylinder head cover sub-assembly and slide the clip to secure it. HINT: Make sure that the clip is positioned as shown in the illustration. |
|
(d) Engage the 2 grommets and pin to install the air cleaner assembly with air cleaner hose.
(e) Engage the wire harness clamp.
(f) Connect the mass air flow meter sub-assembly connector.
18. INSTALL INLET AIR CLEANER ASSEMBLY
(a) Temporarily install the inlet air cleaner assembly with the 2 bolts. |
![]() |
(b) Fully tighten the 2 bolts in the order shown in the illustration.
Torque:
8 N·m {82 kgf·cm, 71 in·lbf}
19. INSTALL COOL AIR INTAKE DUCT SEAL
Click here ![]()
20. INSTALL NO. 1 ENGINE COVER SUB-ASSEMBLY
Click here ![]()
21. INSTALL SERVICE PLUG GRIP
Click here ![]()
22. ADD COOLANT (for Inverter)
Click here ![]()
23. INSPECT FOR COOLANT LEAK (for Inverter)
Click here ![]()
24. PERFORM INITIALIZATION
Click here ![]()
Removal
REMOVAL
The necessary procedures (adjustment, calibration, initialization or registration) that must be performed after parts are removed and installed, or replaced during inverter with converter assembly removal/installation are shown below.
Necessary Procedures After Parts Removed/Installed/ReplacedReplaced Part or Performed Procedure | Necessary Procedure | Effect/Inoperative Function when Necessary Procedure not Performed | Link |
|---|---|---|---|
| *: When performing learning using the Techstream. | |||
Auxiliary battery terminal is disconnected/reconnected |
Perform steering sensor zero point calibration |
Lane departure alert system (w/ Steering Control) |
|
Pre-collision system |
|||
Intelligent clearance sonar system* |
|||
Lighting System (for HV Model with Cornering Light) |
|||
Memorize steering angle neutral point |
Parking assist monitor system |
||
Panoramic view monitor system |
|||
Replacement of inverter with converter assembly |
Resolver learning |
|
|
Replacement of ECM |
Perform Vehicle Identification Number (VIN) registration |
MIL illuminates |
|
CAUTION:
- Orange wire harnesses and connectors indicate high-voltage circuits. To prevent electric shock, always follow the procedure described in the repair manual.
Click here

- To prevent electric shock, wear insulated gloves when working on wire harnesses and components of the high voltage system.

NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
1. REMOVE SERVICE PLUG GRIP
Click here ![]()
2. DRAIN COOLANT (for Inverter)
Click here ![]()
3. REMOVE NO. 1 ENGINE COVER SUB-ASSEMBLY
Click here ![]()
4. REMOVE COOL AIR INTAKE DUCT SEAL
Click here ![]()
5. REMOVE INLET AIR CLEANER ASSEMBLY
(a) Remove the 2 bolts and inlet air cleaner assembly. |
![]() |
6. REMOVE AIR CLEANER ASSEMBLY WITH AIR CLEANER HOSE
(a) Disconnect the mass air flow meter sub-assembly connector. |
![]() |
(b) Disengage the wire harness clamp.
(c) Slide the clip and disconnect the No. 2 ventilation hose from the cylinder head cover sub-assembly. |
|
(d) Loosen the hose clamp and disconnect the air cleaner hose from the throttle body with motor assembly.
(e) Disengage the 2 grommets and pin to remove the air cleaner assembly with air cleaner hose.
7. REMOVE ECM
Click here ![]()
8. DISCONNECT ENGINE ROOM MAIN WIRE
CAUTION:
Be sure to wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
(a) Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector. NOTICE:
|
![]() |
(b) Remove the bolt. |
![]() |
(c) Disengage the clamp and disconnect the engine room main wire.
9. REMOVE CONNECTOR COVER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the bolt (B). |
|
(b) Using a T25 "TORX" socket wrench, remove the bolt (A) and connector cover assembly from the inverter with converter assembly.
NOTICE:
- Do not touch the connector cover assembly waterproof seal.
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
10. CHECK TERMINAL VOLTAGE
CAUTION:
Be sure to wear insulated gloves.
(a) Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors. Standard Voltage: 0 V NOTICE: Do not allow any foreign matter or water to enter the inverter with converter assembly. HINT: Use a measuring range of DC 750 V or more on the voltmeter. |
![]() |
11. TEMPORARILY INSTALL CONNECTOR COVER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
(a) Temporarily install the connector cover assembly to the inverter with converter assembly. |
![]() |
(b) Using a T25 "TORX" socket wrench, install the bolt.
Torque:
4,5 N·m {46 kgf·cm, 40 in·lbf}
NOTICE:
- Do not touch the connector cover assembly waterproof seal.
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
12. DISCONNECT HV FLOOR UNDER WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the bolt. |
|
(b) Disengage the 2 clamps and disconnect the HV floor under wire from the inverter with converter assembly
NOTICE:
- Do not touch the waterproof seal or terminals of the connector.
- Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
- Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
- Insulate the disconnected terminals with insulating tape.
13. DISCONNECT HV AIR CONDITIONING WIRE
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the 2 bolts. |
|
(b) Disengage the clamp and disconnect the HV air conditioning wire from the inverter with converter assembly.
NOTICE:
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
- Do not touch the waterproof seal or terminals of the connector.
- Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
- Insulate the disconnected terminals with insulating tape.
- Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
14. REMOVE WIRE HARNESS CLAMP BRACKET
(a) Remove the nut and wire harness clamp bracket. |
![]() |
15. DISCONNECT ENGINE WIRE
CAUTION:
Be sure to wear insulated gloves.
NOTICE:
Do not allow any foreign matter or water to enter the inverter with converter assembly.
(a) Move the lock lever while pushing the lock on the connector, and disconnect the inverter with converter assembly connector. NOTICE:
|
![]() |
(b) Disengage the 3 clamps (A) and disconnect the No. 1 fuel vapor feed hose. |
![]() |
(c) Remove the bolt.
(d) Disengage the 2 clamps (B).
(e) Disengage the 2 clamps (A) and disconnect the No. 1 fuel vapor feed hose and No. 2 fuel vapor feed hose. |
![]() |
(f) Remove the bolt.
(g) Disengage the clamp (B).
(h) Disconnect the generator temperature sensor connector. |
|
(i) Disconnect the resolver (transmission fluid temperature sensor) connector.
(j) Disconnect the shift lever position sensor connector.
(k) Disengage the clamp.
(l) Disengage the 2 clamps. |
![]() |
(m) Remove the bolt. |
![]() |
(n) Remove the bolt. |
![]() |
(o) Disengage the 2 claws and open the engine wire terminal cover. |
![]() |
(p) Remove the nut. |
![]() |
(q) Disengage the 2 clamps and disconnect the engine wire from the inverter with converter assembly.
16. DISCONNECT TRANSMISSION CONTROL CABLE ASSEMBLY
(a) Remove the nut and disconnect the transmission control cable assembly from the control shaft lever. |
![]() |
(b) Using a screwdriver, disengage the 4 claws and disconnect the transmission control cable assembly with the clip from the No. 1 transmission control cable bracket. |
![]() |
(c) Using a screwdriver, disengage the 2 claws and remove the clip from the transmission control cable assembly. |
![]() |
(d) Remove the 3 bolts and disconnect the transmission control cable assembly from the inverter with converter assembly. |
![]() |
17. DISCONNECT NO. 1 INVERTER COOLING HOSE
(a) Slide the clip and disconnect the No. 1 inverter cooling hose from the inverter with converter assembly. NOTICE: Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter. |
![]() |
18. DISCONNECT NO. 4 INVERTER COOLING HOSE
(a) Slide the clip and disconnect the No. 4 inverter cooling hose from the inverter with converter assembly. NOTICE: Put pieces of cloth into the pipe and disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter. |
![]() |
19. REMOVE INVERTER COVER
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the 2 bolts and inverter cover from the inverter with converter assembly.
NOTICE:
- Make sure to pull the inverter cover straight out, as a connector is connected to the inside of the inverter cover.
- Do not touch the waterproof seal of the inverter cover.
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
- When removing the inverter cover, do not pull the areas (A) as they may deform.
- Make sure that the interlock is installed to the inverter cover.
- Do not remove or excessively tighten the screw of the inverter cover.
*1
Inverter Cover
*a
Screw
- Although the inverter cover may feel loose, this is not due to a malfunction.
HINT:
If necessary, use a screwdriver with its tip wrapped with protective tape as shown in the illustration to remove the inverter cover.
*a |
Interlock |
*b |
Waterproof Seal |
20. DISCONNECT MOTOR CABLE
CAUTION:
Be sure to wear insulated gloves.
(a) Using an insulated tool, remove the 6 bolts. NOTICE:
|
![]() |
(b) Remove the 4 bolts and disconnect the motor cable from the inverter with converter assembly.
*a |
Waterproof Seal |
NOTICE:
- Do not allow any foreign matter or water to enter the inverter with converter assembly.
- Do not touch the waterproof seal or terminals of the motor cable.
- Do not damage the terminals, connector housing or inverter with converter assembly during disconnection.
- Insulate the disconnected terminals with insulating tape.
- After disconnecting the motor cable, wrap it with a plastic bag or equivalent to protect it.
- Cover the hole where the cable was connected with tape (non-residue type) or equivalent to prevent entry of foreign matter.
- To prevent the wire harness from being caught, make sure to bundle the wire harness using insulating tape or equivalent.

21. REMOVE INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
(a) Remove the 5 bolts, 2 nuts and inverter with converter assembly.
NOTICE:
- When removing the inverter with converter assembly, be careful not to damage the parts around it.
- To prevent damage, do not hold the inverter with converter assembly by the connectors, brackets or cooling pipes.
- To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
HINT:
Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter with converter assembly so that coolant does not spill out.
22. REMOVE NO. 1 INVERTER BRACKET
NOTICE:
Make sure to support the inverter with converter assembly at the positions shown in the illustration, otherwise it may be damaged.
*a |
Bottom of Inverter with Converter Assembly |
*b |
Support |
(a) Set the inverter with converter assembly on wooden blocks. |
|
(b) Remove the 2 bolts and No. 1 inverter bracket from the inverter with converter assembly.
23. REMOVE NO. 2 INVERTER BRACKET
(a) Remove the 2 bolts and No. 2 inverter bracket from the inverter with converter assembly. |
|
24. REMOVE WIRE HARNESS CLAMP BRACKET
(a) Remove the 2 bolts and 2 wire harness clamp brackets from the inverter with converter assembly. |
![]() |
(b) Remove the bolt and wire harness clamp bracket from the inverter with converter assembly. |
![]() |
(c) Remove the bolt and wire harness clamp bracket from the inverter with converter assembly. |
![]() |
25. REMOVE INVERTER PROTECTOR
(a) Remove the bolt and inverter protector from the inverter with converter assembly. |
![]() |