Hybrid/EV Battery Precharge Contactor Circuit Short to Ground (P0AE411). Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open (P0AE415). Hybrid/EV Battery Sensor Module (P0
Hybrid/EV Battery Precharge Contactor Circuit Short to Ground (P0AE411)
DESCRIPTION
The SMRs (System Main Relays) are the relays that connect or disconnect the high-voltage system in accordance with commands from the hybrid vehicle control ECU.
There are 3 SMRs and 1 system main resistor. SMRB, SMRP, SMRG and the system main resistor are located in the HV battery junction block assembly.
To connect to the high voltage power system, the vehicle will first turn on SMRP and SMRB to charge the vehicle through the system main resistor. Then, SMRP will be turned off after SMRG is turned on. To shut off the high voltage power system, SMRB and SMRG are turned off.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0AE411 |
Hybrid/EV Battery Precharge Contactor Circuit Short to Ground |
Short to ground in the SMRP circuit: Primary circuit of SMRP is malfunctioning. (2 trip detection logic) |
|
Does not come on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0AE411 |
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here ![]()
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (READY) and wait for 30 seconds or more.
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
WIRING DIAGRAM
Refer to the wiring diagram for the HV battery high-voltage line circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
- Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
HINT:
If DTC P0AE411 is output, the power switch cannot be turned on (READY).
PROCEDURE
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - BODY GROUND)
(a) Disconnect the G46 hybrid vehicle control ECU connector.
(b) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
(c) Reconnect the G46 hybrid vehicle control ECU connector.
| OK | REPLACE HYBRID VEHICLE CONTROL ECU |
|
CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HV BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery cover panel RH.
Click here ![]()
(c) Disconnect the K18 HV battery junction block assembly connector. |
![]() |
(d) Disconnect the G46 hybrid vehicle control ECU.
(e) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
(f) Reconnect the G46 hybrid vehicle control ECU connector.
(g) Reconnect the K18 HV battery junction block assembly connector.
(h) Install the No. 1 HV battery cover panel RH.
| OK | REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open (P0AE415)
DESCRIPTION
Refer to the description for DTC P0AE411.
Click here ![]()
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0AE415 |
Hybrid/EV Battery Precharge Contactor Circuit Short to Auxiliary Battery or Open |
Open or short to +B in SMRP circuit: Primary circuit of SMRP is malfunctioning. (2 trip detection logic) |
|
Does not come on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0AE415 |
|
CONFIRMATION DRIVING PATTERN
HINT:
After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here ![]()
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (READY) and wait for 30 seconds or more.
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.
WIRING DIAGRAM
Refer to the wiring diagram for the HV battery high-voltage line circuit.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
- Make sure to insulate the high-voltage connectors and terminals of the HV battery with insulating tape after removing it.
If the HV battery stored without insulating the connectors and terminals, electric shock or fire may result.
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
HINT:
If DTC P0AE415 is output, the power switch cannot be turned on (READY).
PROCEDURE
READ VALUE USING TECHSTREAM (SMRP STATUS)
(a) Connect the Techstream to the DLC3
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control / Data List / SMRP Status.
Powertrain > Hybrid Control > Data ListSMRP Status
(d) Read the Data List.
Standard:
Tester Display | Condition | Specified Condition |
|---|---|---|
SMRP Status |
Power switch on (IG) |
OFF |
(e) Turn the power switch off.
| NG | GO TO STEP 5 |
|
CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
Click here ![]()
| NG | CONNECT SECURELY |
|
CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK CONNECTOR CONNECTION CONDITION (HV BATTERY JUNCTION BLOCK ASSEMBLY CONNECTOR)
Click here ![]()
| OK | CHECK FOR INTERMITTENT PROBLEMS |
| NG | CONNECT SECURELY |
CHECK HARNESS AND CONNECTOR (SMRP VOLTAGE)
(a) Turn the power switch on (IG).
(b) Measure the voltage according to the value(s) in the table below. Standard Voltage:
|
|
(c) Turn the power switch off.
| NG | GO TO STEP 7 |
|
CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)
Click here ![]()
| OK | REPLACE HYBRID VEHICLE CONTROL ECU |
| NG | CONNECT SECURELY |
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - BODY GROUND)
(a) Disconnect the G46 hybrid vehicle control ECU connector.
(b) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
(c) Reconnect the G46 hybrid vehicle control ECU connector.
| NG | GO TO STEP 9 |
|
CHECK HARNESS AND CONNECTOR (SHORT TO POWER SUPPLY WIRES)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery cover panel RH.
Click here ![]()
(c) Disconnect the K18 HV battery junction block assembly connector. |
![]() |
(d) Disconnect the G46 hybrid vehicle control ECU connector.
(e) Turn the power switch on (IG).
(f) Measure the voltage according to the value(s) in the table below. Standard Voltage:
NOTICE: Turning the power switch on (IG) with the hybrid vehicle control ECU connector and the HV battery junction block assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection. |
|
(g) Turn the power switch off.
(h) Reconnect the G46 hybrid vehicle control ECU connector.
(i) Reconnect the K18 HV battery junction block assembly connector.
(j) Install the No. 1 HV battery cover panel RH.
| OK | REPLACE HYBRID VEHICLE CONTROL ECU |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
CHECK CONNECTOR CONNECTION CONDITION (FLOOR WIRE CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - HV BATTERY JUNCTION BLOCK ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery cover panel RH.
Click here ![]()
(c) Disconnect the K18 HV battery junction block assembly connector. |
![]() |
(d) Disconnect the G46 hybrid vehicle control ECU connector.
(e) Measure the resistance according to the value(s) in the table below. Standard Resistance (Check for Open):
Standard Resistance (Check for Short):
|
|
(f) Reconnect the G46 hybrid vehicle control ECU connector.
(g) Reconnect the K18 HV battery junction block assembly connector.
(h) Install the No. 1 HV battery cover panel RH.
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK HARNESS AND CONNECTOR (HV BATTERY JUNCTION BLOCK ASSEMBLY - BODY GROUND)
Click here ![]()
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
INSPECT HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRP)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 HV battery cover panel RH.
Click here ![]()
(c) Disconnect the K18 HV battery junction block assembly connector.
(d) Measure the resistance according to the value(s) in the table below.
*a |
Component without harness connected (HV Battery Junction Block Assembly) |
- |
- |
Standard Resistance:
Tester Connection | Condition | Specified Condition |
|---|---|---|
K18-2 (SMRP) - K18-3 (GND) |
-40 to 80 °C |
140 to 290 Ω |
(e) Reconnect the K18 HV battery junction block assembly connector.
(f) Install the No. 1 HV battery cover panel RH.
| OK | CHECK FOR INTERMITTENT PROBLEMS |
| NG | REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY |
Hybrid/EV Battery Sensor Module (P0AFC00,P0AFC16,P0AFC96,P308A12)
DESCRIPTION
If the battery voltage sensor detects an internal malfunction, it sends an error signal to the hybrid vehicle control ECU. When the hybrid vehicle control ECU receives the error signal from the battery voltage sensor, the ECU warns the driver and performs fail-safe control.
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0AFC00 |
Hybrid/EV Battery Sensor Module |
The hybrid vehicle control ECU receives an error signal from the battery voltage sensor. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P0AFC16 |
Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |
The hybrid vehicle control ECU receives an error signal from the battery voltage sensor. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P0AFC96 |
Hybrid/EV Battery Sensor Module Component Internal Failure |
The hybrid vehicle control ECU receives an error signal from the battery voltage sensor. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P308A12 |
Hybrid/EV Battery Voltage Sensor All Circuit Short to Auxiliary Battery |
The hybrid vehicle control ECU receives an error signal from the battery voltage sensor. (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0AFC00 |
Hybrid Battery Sensor Module Power Supply Voltage |
P0AFC16 |
|
P0AFC96 |
|
P308A12 |
MONITOR DESCRIPTION
If the battery voltage sensor detects an internal malfunction in the unit itself, the hybrid vehicle control ECU will illuminate the MIL and store a DTC.
MONITOR STRATEGY
Related DTCs |
P0AFC (INF P0AFC00/P0AFC16/P0AFC96), P308D (INF P308A12): Hybrid Battery Pack Sensor Module |
Required sensors/components |
Battery voltage sensor |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
Immediately |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Battery voltage sensor |
DTC P0AFC (INF P0AFC00/P0AFC16/P0AFC96) is not detected DTC P308D (INF P308A12) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 10 seconds or more.[*1]
HINT:
[*1]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Hybrid Control / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK HARNESS AND CONNECTOR (IGCT VOLTAGE)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
- Check and record any DTCs, INF codes and freeze frame data, then disconnect the cable from the negative (-) auxiliary battery terminal.
- After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 hybrid battery exhaust duct.
Click here ![]()
(c) Connect the cable to the negative (-) auxiliary battery terminal.
(d) Turn the power switch on (IG).
(e) Measure the voltage according to the value(s) in the table below. Standard Voltage:
NOTICE: Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection. |
|
(f) Turn the power switch off.
(g) Disconnect the cable from the negative (-) auxiliary battery terminal.
(h) Install the No. 1 hybrid battery exhaust duct.
| OK | REPLACE BATTERY VOLTAGE SENSOR |
|
CHECK HARNESS AND CONNECTOR (BATTERY VOLTAGE SENSOR - BODY GROUND)
CAUTION:
Be sure to wear insulated gloves.
(a) Check that the service plug grip is not installed.
NOTICE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
(b) Remove the No. 1 hybrid battery exhaust duct.
Click here ![]()
(c) Measure the resistance according to the value(s) in the table below. Standard Resistance:
|
|
(d) Install the No. 1 hybrid battery exhaust duct.
| OK | REPAIR OR REPLACE HARNESS OR CONNECTOR (IGCT NO. 2 FUSE - BATTERY VOLTAGE SENSOR) |
| NG | REPAIR OR REPLACE HARNESS OR CONNECTOR (BATTERY VOLTAGE SENSOR - BODY GROUND) |