DC/DC Converter Stuck On (P0A949E,P0D3319)
DTC SUMMARY
MALFUNCTION DESCRIPTION
This DTC indicates that a large current flowed in the boost converter. The cause of this malfunction may be one of the following:
Area | Main Malfunction Description |
|---|---|
Hybrid vehicle transaxle assembly |
|
Resolver |
Open or short circuit in the motor resolver or generator resolver |
| Inverter |
|
Inverter cooling system |
|
DESCRIPTION
For a description of the boost converter.
Click here ![]()
DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate |
|---|---|---|---|---|---|
P0A949E |
DC/DC Converter Stuck On |
Boost converter fail signal detected (circuit malfunction) (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
P0D3319 |
DC/DC Converter Circuit Current Above Threshold |
Boost converter fail signal detected: A malfunction is detected in any of the boost converter components (inverter, hybrid vehicle transaxle, motor generator control ECU, etc.). (1 trip detection logic) |
|
Comes on |
Master Warning Light: Comes on |
DTC No. | Data List |
|---|---|
P0A949E P0D3319 |
|
MONITOR DESCRIPTION
If excessive amperage flows through the boost converter, the boost converter will transmit a boost converter fail signal to the motor generator control ECU. Upon receiving this signal, the motor generator control ECU will illuminate the MIL and set a DTC.
MONITOR STRATEGY
Related DTCs |
P0A94 (INF P0A949E): FCV detection (Circuit malfunction) P0D33 (INF P0D3319): FCV detection (Over current malfunction) |
Required sensors/components |
Boost converter |
Frequency of operation |
Continuous |
Duration |
TMC's intellectual property |
MIL operation |
1 driving cycle |
Sequence of operation |
None |
TYPICAL ENABLING CONDITIONS
The monitor will run whenever the following DTCs are not stored |
TMC's intellectual property |
Other conditions belong to TMC's intellectual property |
- |
TYPICAL MALFUNCTION THRESHOLDS
TMC's intellectual property |
- |
COMPONENT OPERATING RANGE
Motor generator control ECU |
DTC P0A94 (INF P0A949E) is not detected DTC P0D33 (INF P0D3319) is not detected |
CONFIRMATION DRIVING PATTERN
HINT:
- After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.
Click here

- When clearing the permanent DTCs, refer to the "CLEAR PERMANENT DTC" procedure.
Click here

- Connect the Techstream to the DLC3.
- Turn the power switch on (IG) and turn the Techstream on.
- Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).
- Turn the power switch off and wait for 2 minutes or more.
- Turn the power switch on (IG) and turn the Techstream on.
- With power switch on (IG) and wait for 5 seconds or more. [*1]
- Turn the power switch on (READY) and wait for 5 seconds or more. [*2]
- Depress the accelerator pedal of the vehicle with the engine stopped and the shift lever in P to start the engine. [*3]
NOTICE:
As the state of charge of the HV battery may be low after driving in fail-safe mode, it will automatically be charged for 5 to 10 minutes with power switch on (READY) after repairs have been performed.
HINT:
- Check that there are no abnormalities (abnormal sounds, coolant leaks, etc.).
- [*1] to [*3]: Normal judgment procedure.
The normal judgment procedure is used to complete DTC judgment and also used when clearing permanent DTCs.
- Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.
- Check the DTC judgment result.
HINT:
- If the judgment result shows NORMAL, the system is normal.
- If the judgment result shows ABNORMAL, the system has a malfunction.
- If the judgment result shows INCOMPLETE or N/A, perform the normal judgment procedure again.
WIRING DIAGRAM
Refer to the wiring diagram for the Generator Resolver Circuit.
Click here ![]()
Refer to the wiring diagram for the Motor Resolver Circuit.
Click here ![]()
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the Inverter Low-voltage Circuit.
Click here ![]()
Refer to the wiring diagram for the Cooling System.
Click here ![]()
CAUTION:
- Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
- Inspecting the high-voltage system
- Disconnecting the low voltage connector of the inverter with converter assembly
- Disconnecting the low voltage connector of the HV battery
- To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

- After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

- After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.
Click here

HINT:
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
*a
Without waiting for 10 minutes
NOTICE:
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work.
Click here ![]()
PROCEDURE
CHECK DTC OUTPUT
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Hybrid Control and Motor Generator / Trouble Codes.
(d) Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes Powertrain > Motor Generator > Trouble CodesResult | Proceed to |
|---|---|
P0A949E or P0D3319 only is output, or DTCs except the ones in the table below are also output. |
A |
DTCs of hybrid control system in the tables below are output. |
B |
DTCs of motor generator control system in the tables below are output. |
C |
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Insulation Malfunction |
Hybrid control system |
P1C7C49 |
Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
P1C7D49 |
Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure |
||
P1C7E49 |
Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure |
||
P1C7F49 |
Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure |
||
System Main Relay or High Voltage Circuit Malfunction |
Hybrid control system |
P0AD911 |
Hybrid/EV Battery Positive Contactor Circuit Short to Ground |
P0AD915 |
Hybrid/EV Battery Positive Contactor Circuit Short to Battery or Open |
||
P0ADD11 |
Hybrid/EV Battery Negative Contactor Circuit Short to Ground |
||
P0ADD15 |
Hybrid/EV Battery Negative Contactor Circuit Short to Battery or Open |
||
P1C8449 |
High Voltage Power Resource Circuit Short during Ready ON |
||
HV Battery Malfunction |
Hybrid control system |
P0AFC16 |
Hybrid/EV Battery Sensor Module Circuit Voltage Below Threshold |
P0AFC96 |
Hybrid/EV Battery Sensor Module Component Internal Failure |
||
P1CBE1E |
Hybrid/EV Battery Block 1 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CBF1E |
Hybrid/EV Battery Block 2 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC01E |
Hybrid/EV Battery Block 3 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC11E |
Hybrid/EV Battery Block 4 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC21E |
Hybrid/EV Battery Block 5 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC31E |
Hybrid/EV Battery Block 6 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC41E |
Hybrid/EV Battery Block 7 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC51E |
Hybrid/EV Battery Block 8 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC61E |
Hybrid/EV Battery Block 9 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CC71E |
Hybrid/EV Battery Block 10 (Voltage Difference) Circuit Resistance Out of Range |
||
P1CFD1E |
Hybrid/EV Battery Block 11 (Voltage Difference) Circuit Resistance Out of Range |
||
P301100 |
Hybrid/EV Battery Block 1 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301200 |
Hybrid/EV Battery Block 2 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301300 |
Hybrid/EV Battery Block 3 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301400 |
Hybrid/EV Battery Block 4 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301500 |
Hybrid/EV Battery Block 5 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301600 |
Hybrid/EV Battery Block 6 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301700 |
Hybrid/EV Battery Block 7 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301800 |
Hybrid/EV Battery Block 8 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P301900 |
Hybrid/EV Battery Block 9 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P302000 |
Hybrid/EV Battery Block 10 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
P302100 |
Hybrid/EV Battery Block 11 (Internal Resistance Difference) Circuit Resistance Out of Range (Extreme) |
||
U029A87 |
Lost Communication with Hybrid/EV Battery Sensor Module Missing Message |
||
Malfunction Content | System | Relevant DTC |
|
|---|---|---|---|
Microcomputer malfunction |
Motor generator control system |
P0A1A47 |
Generator Control Module Watchdog / Safety μC Failure |
P0A1A49 |
Generator Control Module Internal Electronic Failure |
||
P0A1B1F |
Generator Control Module Circuit Intermittent |
||
P1C2A1C |
Generator A/D Converter Circuit Circuit Voltage Out of Range |
||
P1C2A49 |
Generator A/D Converter Circuit Internal Electronic Failure |
||
P1C2B1C |
Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range |
||
P1C2B49 |
Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure |
||
P313383 |
Communication Error from Generator to Drive Motor "A" Value of Signal Protection Calculation Incorrect |
||
P313386 |
Communication Error from Generator to Drive Motor "A" Signal Invalid |
||
P313387 |
Communication Error from Generator to Drive Motor "A" Missing Message |
||
P313483 |
Communication Error from Drive Motor "A" to Generator Value of Signal Protection Calculation Incorrect |
||
P313486 |
Communication Error from Drive Motor "A" to Generator Signal Invalid |
||
P313487 |
Communication Error from Drive Motor "A" to Generator Missing Message |
||
Hybrid control system |
P0A1B49 |
Drive Motor "A" Control Module Internal Electronic Failure |
|
Power source circuit malfunction |
Motor generator control system |
P06B01C |
Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range |
P06D61C |
Generator Control Module Offset Power Circuit Voltage Out of Range |
||
Communication malfunction |
Motor generator control system |
P312487 |
Lost Communication between Drive Motor "A" and HV ECU Missing Message |
Hybrid control system |
P312387 |
Lost Communication with Drive Motor Control Module "A" from Hybrid/EV Control Module Missing Message |
|
Sensor and actuator circuit malfunction |
Motor generator control system |
P0A3F16 |
Drive Motor "A" Position Sensor Circuit Voltage Below Threshold |
P0A3F21 |
Drive Motor "A" Position Sensor Signal Amplitude < Minimum |
||
P0A3F22 |
Drive Motor "A" Position Sensor Signal Amplitude > Maximum |
||
P0A4B16 |
Generator Position Sensor Circuit Voltage Below Threshold |
||
P0A4B21 |
Generator Position Sensor Signal Amplitude < Minimum |
||
P0A4B22 |
Generator Position Sensor Signal Amplitude > Maximum |
||
P0A6012 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Battery |
||
P0A6014 |
Drive Motor "A" Phase V Current (High Resolution) Circuit Short to Ground or Open |
||
P0A601C |
Drive Motor "A" Phase V Current (High Resolution) Circuit Voltage Out of Range |
||
P0A6312 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Battery |
||
P0A6314 |
Drive Motor "A" Phase W Current (High Resolution) Circuit Short to Ground or Open |
||
P0A631C |
Drive Motor "A" Phase W Current (High Resolution) Circuit Voltage Out of Range |
||
P0BE512 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Battery |
||
P0BE514 |
Drive Motor "A" Phase U Current Sensor Circuit Short to Ground or Open |
||
P0BE528 |
Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BE912 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Battery |
||
P0BE914 |
Drive Motor "A" Phase V Current Sensor Circuit Short to Ground or Open |
||
P0BE928 |
Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BED12 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Battery |
||
P0BED14 |
Drive Motor "A" Phase W Current Sensor Circuit Short to Ground or Open |
||
P0BED28 |
Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0BFD62 |
Drive Motor "A" Phase U-V-W Current Sensor Signal Compare Failure |
||
P0C5013 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Open |
||
P0C5016 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C5017 |
Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C5A13 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Open |
||
P0C5A16 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C5A17 |
Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0C6413 |
Generator Position Sensor Circuit "A" Circuit Open |
||
P0C6416 |
Generator Position Sensor Circuit "A" Circuit Voltage Below Threshold |
||
P0C6417 |
Generator Position Sensor Circuit "A" Circuit Voltage Above Threshold |
||
P0C6913 |
Generator Position Sensor Circuit "B" Circuit Open |
||
P0C6916 |
Generator Position Sensor Circuit "B" Circuit Voltage Below Threshold |
||
P0C6917 |
Generator Position Sensor Circuit "B" Circuit Voltage Above Threshold |
||
P0D2D16 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold |
||
P0D2D17 |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold |
||
P0DFA62 |
Generator Phase U-V-W Current Sensor Signal Compare Failure |
||
P0E0012 |
Generator Phase U Current Sensor Circuit Short to Battery |
||
P0E0014 |
Generator Phase U Current Sensor Circuit Short to Ground or Open |
||
P0E0028 |
Generator Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0412 |
Generator Phase V Current Sensor Circuit Short to Battery |
||
P0E0414 |
Generator Phase V Current Sensor Circuit Short to Ground or Open |
||
P0E0428 |
Generator Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E0812 |
Generator Phase W Current Sensor Circuit Short to Battery |
||
P0E0814 |
Generator Phase W Current Sensor Circuit Short to Ground or Open |
||
P0E0828 |
Generator Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P0E3116 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Below Threshold |
||
P0E3117 |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
||
P0E5111 |
DC/DC Converter Current Sensor Circuit Short to Ground |
||
P0E5115 |
DC/DC Converter Current Sensor Circuit Short to Battery or Open |
||
P0E5128 |
DC/DC Converter Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure |
||
P1CFF62 |
Hybrid/EV Battery Current/DC/DC Converter Current Signal Compare Failure |
||
P1CAC49 |
Generator Position Sensor Internal Electronic Failure |
||
P1CAD49 |
Drive Motor "A" Position Sensor Internal Electronic Failure |
||
P1CAF38 |
Generator Position Sensor REF Signal Cycle Malfunction Signal Frequency Incorrect |
||
P1CB038 |
Drive Motor "A" Position Sensor REF Signal Frequency Incorrect |
||
Hybrid control system |
P0C7600 |
Hybrid/EV Battery System Discharge Time Too Long |
|
P0D2D1C |
Drive Motor "A" Inverter after Boosting Voltage Sensor Circuit Voltage Out of Range |
||
P0E311C |
Drive Motor "A" Inverter before Boosting Voltage Sensor Circuit Voltage Out of Range |
||
System malfunction |
Motor generator control system |
P0A9000 |
Drive Motor "A" Performance |
P0A9200 |
Hybrid Generator Performance |
||
P0BFF1D |
Drive Motor "A" Circuit Current Out of Range |
||
P0C1900 |
Drive Motor "A" Execution Torque Performance |
||
P0CA300 |
DC/DC Converter Step Up Voltage Performance |
||
P0E7100 |
Generator Execution Torque Performance |
||
P1CA51D |
Hybrid Generator Circuit Current Out of Range |
||
P314F1F |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
||
P31531D |
DC/DC Converter Current Sensor Circuit Current Out of Range |
||
Hybrid control system |
P0A9300 |
Inverter "A" Cooling System |
|
P0AA649 |
Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
||
P0C7396 |
Motor Electronics Coolant Pump "A" Component Internal Failure |
||
P314A31 |
Motor Electronics Coolant Pump "A" No Signal |
||
Relevant DTC |
|
|---|---|
P0A3F1F |
Drive Motor "A" Position Sensor Circuit Intermittent |
P0A4B1F |
Generator Position Sensor Circuit Intermittent |
P0A601F |
Drive Motor "A" Phase V Current (High Resolution) Circuit Intermittent |
P0A631F |
Drive Motor "A" Phase W Current (High Resolution) Circuit Intermittent |
P0C501F |
Drive Motor "A" Position Sensor Circuit "A" Circuit Intermittent |
P0C5A1F |
Drive Motor "A" Position Sensor Circuit "B" Circuit Intermittent |
P0C641F |
Generator Position Sensor Circuit "A" Circuit Intermittent |
P0C691F |
Generator Position Sensor Circuit "B" Circuit Intermittent |
P0D2D1F |
Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Intermittent |
P0E311F |
DC/DC Converter Voltage Sensor "A" (VL) Circuit Intermittent |
P1C601F |
Generator Control Module Position Sensor REF Power Source Circuit Intermittent |
P1C621F |
Generator Control Module Offset Power Circuit Intermittent |
P1C641F |
Generator Control Module Circuit Intermittent |
P1C651F |
Generator Control Module Circuit Intermittent |
P1C671F |
Drive Motor "A" Phase U-V-W Current Sensor Circuit Intermittent |
P1C691F |
Generator Phase U-V-W Current Sensor Circuit Intermittent |
P31241F |
Lost Communication between Drive Motor "A" and HV ECU Circuit Intermittent |
HINT:
- P0A949E or P0D3319 may be output as a result of the malfunction indicated by the DTCs above.
- The chart above is listed in inspection order of priority.
- Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
- If DTC P0A949E is output, replace the inverter with converter assembly after completing repairs.
(e) Turn the power switch off.
| B | GO TO DTC CHART (HYBRID CONTROL SYSTEM) |
| C | GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM) |
|
CHECK FREEZE FRAME DATA AND DIAGNOSIS RELATED INFORMATION
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Utility / Diagnosis Related Information.
Powertrain > Motor Generator > UtilityDiagnosis Related Information
(d) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Powertrain > Motor Generator > Trouble Codes(e) Read the diagnosis related information and freeze frame data of DTC P0A949E or P0D3319.
Result | Proceed to |
|---|---|
DTC P312487 is listed in Diagnosis Related Information. |
A |
DTC P312487 is not listed in Diagnosis Related Information and the value of freeze frame data item Emergency Shutdown Signal is ON. |
B |
Other than above |
C |
(f) Turn the power switch off.
| A | GO TO DTC CHART (P312487) |
| B | GO TO DTC CHART (P321E9F) |
|
CHECK FREEZE FRAME DATA
(a) Connect the Techstream to the DLC3.
(b) Turn the power switch on (IG).
(c) Enter the following menus: Powertrain / Motor Generator / Trouble Codes.
Powertrain > Motor Generator > Trouble Codes(d) Read the freeze frame data of DTC P0A949E or P0D3319.
Result | Proceed to |
|---|---|
Boosting Converter Temperature (Upper) and Boosting Converter Temperature 1 (Lower) is 120 °C or more |
A |
Other than above |
B |
(e) Turn the power switch off.
| B | GO TO STEP 5 |
|
CHECK COOLING SYSTEM
Click here ![]()
| NEXT | GO TO STEP 5 |
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Click here ![]()
Result | Proceed to |
|---|---|
OK |
A |
NG (The connector is not connected securely.) |
B |
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) |
C |
| B | CONNECT SECURELY |
| C | REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
CHECK GENERATOR RESOLVER CIRCUIT
Click here ![]()
|
CHECK MOTOR RESOLVER CIRCUIT
Click here ![]()
|
CHECK GENERATOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
|
CHECK MOTOR HIGH-VOLTAGE CIRCUIT
Click here ![]()
|
CHECK INVERTER LOW-VOLTAGE CIRCUIT
Click here ![]()
HINT:
If the "Inverter Low-voltage Circuit" inspection results are normal, perform the next step.
|
CHECK FREEZE FRAME DATA
(a) Read the freeze frame data for DTC P0A949E or DTC P0D3319.
NOTICE:
As freeze frame data is stored immediately before and after a DTC is stored, make sure to only read the values for the moment the DTC was stored ("0(s)").
Result | Proceed to |
|---|---|
"Inverter Input Current" is less than 50 A. |
A |
"Inverter Input Current" is 50 A or more. |
B |
(b) Turn the power switch off.
| A | REPLACE INVERTER WITH CONVERTER ASSEMBLY |
| B | REPLACE INVERTER WITH CONVERTER ASSEMBLY, HV BATTERY JUNCTION BLOCK ASSEMBLY AND BATTERY TERMINAL BLOCK |