Heater & Air Conditioning Control System - Basic Inspection
- Diagnosis and Repair Work Flow
- Operation Inspection
- Additional Service When Replacing Control Unit
- Configuration (hvac)
- System Setting
Diagnosis and Repair Work Flow Nissan Pathfinder R53
Work Flow
OVERALL SEQUENCE

DETAILED FLOW
GET INFORMATION FOR SYMPTOM
Get detailed information from the customer about the symptom (the condition and the environment when the incident/malfunction occurs).
Check operation condition of the function that is malfunctioning.
GO TO 2.
CHECK DTC
Check DTC.
Perform the following procedure if DTC is detected:
Record DTC and freeze frame data (print them).
Erase DTC.
Study the relationship between the cause detected by DTC and the symptom described by the customer.
Check related service bulletins for information.
Are any symptoms described and any DTC detected?
Symptom is described, DTC is detected>>GO TO 3.
Symptom is described, DTC is not detected>>GO TO 4.
Symptom is not described, DTC is detected>>GO TO 5.
CONFIRM THE SYMPTOM
Try to confirm the symptom described by the customer.
Also study the normal operation and fail-safe related to the symptom.
Verify relation between the symptom and the condition when the symptom is detected.
>>GO TO 5.
CONFIRM THE SYMPTOM
Try to confirm the symptom described by the customer.
Verify relation between the symptom and the condition when the symptom is detected.
>>GO TO 6.
PERFORM DTC CONFIRMATION PROCEDURE
Perform DTC CONFIRMATION PROCEDURE for the detected DTC, and then check that DTC is detected again. At this time, always connect CONSULT to the Nissan Pathfinder vehicle, and check self diagnostic results in real time.
If two or more DTCs are detected, refer to DTC INSPECTION PRIORITY CHART, and determine trouble diagnosis order.
Is DTC detected?
YES>>GO TO 7.
NO>>Check according to Intermittent Incident.
DETECT MALFUNCTIONING SYSTEM BY SYMPTOM DIAGNOSIS
Detect malfunctioning system according to SYMPTOM DIAGNOSIS based on the confirmed symptom in step 4, and determine the trouble diagnosis order based on possible causes and symptom.
Is the symptom described?
YES>>GO TO 7.
NO>>Monitor input data from related sensors or check voltage of related module terminals using CONSULT.
DETECT MALFUNCTIONING PART BY DIAGNOSIS PROCEDURE
Inspect according to Diagnosis Procedure of the system.
Is malfunctioning part detected?
YES>>GO TO 8.
NO>>Check according to Intermittent Incident.
REPAIR OR REPLACE THE MALFUNCTIONING PART
Repair or replace the malfunctioning part.
Reconnect parts or connectors disconnected during Diagnosis Procedure again after repair and replacement.
Check DTC. If DTC is detected, erase it.
GO TO 9.
FINAL CHECK
When DTC is detected in step 2, perform DTC CONFIRMATION PROCEDURE again, and then check that the malfunction is repaired securely.
When symptom is described by the customer, refer to confirmed symptom in step 3 or 4, and check that the symptom is not detected.
Is DTC detected and does symptom remain?
YES>>DTC is detected: GO TO 7.
YES>>Symptom remains: GO TO 4.
NO>>Before returning the Nissan Pathfinder vehicle to the customer, always erase DTC.
Operation Inspection Nissan Pathfinder SUV
Automatic Air Conditioning System
Work Procedure
DESCRIPTION
The purpose of the operation inspection is to check that the individual system operates normally.
| Check condition | : Engine running at normal operating temperature. |
OPERATION INSPECTION
CHECK MEMORY FUNCTION
Press AUTO switch to activate air conditioning.
Set temperature to 89°F (32.0°C) by operating temperature control dial (driver side).
Press ON·OFF switch.
Ignition switch OFF.
Ignition switch ON.
Press AUTO switch.
Check that the set temperature 89°F (32.0°C) is maintained.
Is the inspection result normal?
YES>>GO TO 2.
NO>>GO TO 11.
CHECK FAN SPEED
Start engine.
Operate fan switch and check that fan speed changes.
Check operation for all fan speeds.
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 11.
CHECK AIR OUTLET
Operate fan switch to set the fan speed to maximum speed.
Operate MODE switch and DEF switch.
Check that air outlets change according to each indicated air outlet by placing a hand in front of the outlets.
Is the inspection result normal?
YES>>With rear air control: GO TO 4.
YES>>Without rear air control: GO TO 5.
NO>>GO TO 11.
CHECK AIR INLET (WITH REAR AIR CONTROL)
Press REC switch to set the air inlet to recirculation. The REC switch indicator turns ON.
Listen to intake sound and confirm air inlets change.
Press FRE switch again to set the air inlet to fresh air intake. The FRE switch indicator turns ON.
Listen to intake sound and confirm air inlets change.
Is the inspection result normal?
YES>>GO TO 6.
NO>>GO TO 11.
CHECK AIR INLET (WITHOUT REAR AIR CONTROL)
Press intake switch to set the air inlet to recirculation. The intake switch indicator turns ON.
Listen to intake sound and confirm air inlets change.
Press intake switch again to set the air inlet to fresh air intake. The intake switch indicator turns OFF.
Listen to intake sound and confirm air inlets change.
Is the inspection result normal?
YES>>GO TO 6.
NO>>GO TO 11.
CHECK A/C COMPRESSOR
Press A/C switch. The A/C switch indicator turns ON.
Check visually and by sound that the A/C compressor operates.
Press A/C switch again. The A/C switch indicator turns OFF.
Check that A/C compressor stops.
Is the inspection result normal?
YES>>GO TO 7.
NO>>GO TO 11.
CHECK DISCHARGE AIR TEMPERATURE
Operate temperature control dial (driver side).
Check that discharge air temperature (driver side) changes.
Operate temperature control dial (passenger side).
Check that discharge air temperature (passenger side) changes.
Operate temperature control switch (rear air control).
Check that discharge rear air temperature changes.
Press SYNC switch. SYNC switch indicator turns ON.
Check that air temperature setting [front (driver side/passenger side) / rear] is unified to the driver side temperature setting.
Is the inspection result normal?
YES>>GO TO 8.
NO>>GO TO 11.
CHECK WITH TEMPERATURE SETTING LOWERED
Operate A/C compressor.
Operate temperature control dial (driver side) to lower the set temperature to "Lo".
Check that cool air blows from the air outlets.
Is the inspection result normal?
YES>>GO TO 9.
NO>>GO TO 11.
CHECK TEMPERATURE INCREASE
Warm up engine to the normal operating temperature.
Operate temperature control dial (driver side) to raise the set temperature to "Hi".
Check that warm air blows from the air outlets.
Is the inspection result normal?
YES>>GO TO 10.
NO>>GO TO 11.
CHECK AUTO MODE
Press AUTO switch and check that AUTO indicator turns ON.
Operate temperature control switch (driver side) to check that fan speed or air outlet changes (the air outlet or fan speed varies depending on the ambient temperature, in-Nissan Pathfinder vehicle temperature, set temperature, and etc.).
Is the inspection result normal?
YES>>Inspection End.
NO>>GO TO 11.
CHECK SELF-DIAGNOSIS
CONSULT
Perform self-diagnosis.
Check that any DTC is detected.
Is any DTC detected?
YES>>Refer to DTC Index, and perform the appropriate diagnosis.
NO>>GO TO 12.
CHECK FAIL-SAFE ACTIVATION
Check that symptom is applied to the fail-safe activation. Refer to Fail-safe.
>>Refer to Symptom Table, and perform the appropriate diagnosis.
Additional Service When Replacing Control Unit Nissan Pathfinder Fifth generation
Description
After replaced A/C auto amp., it is necessary to perform control unit configuration with CONSULT. For details, refer to Work Procedure.
AFTER REPLACEMENT
Work Procedure
REPLACE A/C AUTO AMP.
Replace A/C auto amp. Refer to Removal and Installation.
>>GO TO 2.
WRITING Nissan Pathfinder Vehicle SPECIFICATION
Perform configuration (HVAC). Refer to Description.
>>Work End.
Configuration (hvac) Nissan Pathfinder 5th Gen
Description
Vehicle specification needs to be written with CONSULT because it is not written after replacing the A/C auto amp.
The configuration requires network connection. CONSULT connects to network and then it downloads the configuration data from the server. Then CONSULT writes the Nissan Pathfinder vehicle specification to the A/C auto amp.
Refer to Work Procedure.
The configuration no need to “save” configuration data from the A/C auto amp. The configuration data is always generated freshly at the server and then downloaded to the CONSULT.
Work Procedure
WRITING VEHICLE SPECIFICATION
CONSULT
Perform writing Nissan Pathfinder vehicle specification to A/C auto amp. following "Automatic Configuration" procedure of "Configuration" according to CONSULT Operation Manual.
>>Work End.
System Setting Nissan Pathfinder 2022
Temperature Setting Trimmer (Front)
DESCRIPTION
If the temperature felt by the customer is different from the air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
CONSULT
Select “TEMP SET CORRECT” in “Work support” mode of “HVAC”.
| Work support items | Display (°C) | Display (°F) |
|---|---|---|
| TEMP SET CORRECT | 3.0 | 6 |
| 2.5 | 5 | |
| 2.0 | 4 | |
| 1.5 | 3 | |
| 1.0 | 2 | |
| 0.5 | 1 | |
| 0 (initial status) | 0 (initial status) | |
| −0.5 | −1 | |
| −1.0 | −2 | |
| −1.5 | −3 | |
| −2.0 | −4 | |
| −2.5 | −5 | |
| −3.0 | −6 |
Temperature Setting Trimmer (Rear)
DESCRIPTION
If the temperature felt by the customer is different from the rear air flow temperature controlled by the temperature setting, the A/C auto amp. control temperature can be adjusted to compensate for the temperature setting.
HOW TO SET
CONSULT
Select “TEMP SET CORRECT” in “Work support” mode of “HVAC”.
| Work support items | Display (°C) | Display (°F) |
|---|---|---|
| TEMP SET CORRECT | 3.0 | 6 |
| 2.5 | 5 | |
| 2.0 | 4 | |
| 1.5 | 3 | |
| 1.0 | 2 | |
| 0.5 | 1 | |
| 0 (initial status) | 0 (initial status) | |
| −0.5 | −1 | |
| −1.0 | −2 | |
| −1.5 | −3 | |
| −2.0 | −4 | |
| −2.5 | −5 | |
| −3.0 | −6 |
Inlet Port Memory Function (REC)
DESCRIPTION
If the ignition switch is placed to the OFF position while the intake switch is set to ON (recirculation), “Perform the memory” or “Do not perform the memory” of intake switch ON (recirculation) condition can be selected.
If “Perform the memory” was set, the intake switch will be ON (recirculation) when placing the ignition switch to the ON position again.
If “Do not perform the memory” was set, the air inlets will be controlled automatically when placing the ignition switch to the ON position again.
HOW TO SET
CONSULT
Select “REC MEMORY SET” in “Work support” mode of “HVAC”.
| Work support items | Display | Setting |
|---|---|---|
| REC MEMORY SET | WITHOUT (initial status) | Perform the memory of manual REC |
| WITH | Do not perform the memory of manual REC (auto control) |
Inlet Port Memory Function (FRE)
DESCRIPTION
If the ignition switch is placed to the OFF position while the intake switch is set to OFF (fresh air intake), “Perform the memory” or “Do not perform the memory” of intake switch OFF (fresh air intake) condition can be selected.
If “Perform the memory” was set, the intake switch will be OFF (fresh air intake) when placing the ignition switch to the ON position again.
If “Do not perform the memory” was set, the air inlets will be controlled automatically when placing the ignition switch to the ON position again.
HOW TO SET
CONSULT
Select “FRE MEMORY SET” in “Work support” mode of “HVAC”.
| Work support items | Display | Setting |
|---|---|---|
| FRE MEMORY SET | WITHOUT | Perform the memory of manual FRE |
| WITH (initial status) | Do not perform the memory of manual FRE (auto control) |
Foot Position Setting Trimmer
DESCRIPTION
In FOOT mode, the air blowing to DEF can change ON/OFF.
HOW TO SET
CONSULT
Select “BLOW SET” in “Work support” mode of “HVAC”.
| Work support items | Display | Defroster door position | |
|---|---|---|---|
| Auto control | Manual control | ||
| BLOW SET | Mode1 | OPEN | CLOSE |
| Mode2 (initial status) | OPEN | OPEN | |
| Mode3 | CLOSE | OPEN | |
| Mode4 | CLOSE | CLOSE | |
Setting of Target Evaporator Temperature Upper Limiit Value
DESCRIPTION
Setting of upper limit value of target evaporator temperature can be changed. Control characteristic of compressor control (freezing protection control and refrigerant discharge amount control) changes according to change of the setting, and then operation ratio of compressor and refrigerant discharge amount are changed. According to change of the setting, control characteristic focusing on the fuel consumption can be adjusted to control characteristic focusing on the cooling capacity.
HOW TO SET
CONSULT
Select “TARGET EVAPORATOR TEMP UPPER LIMIT SETTING” in “Work support” mode of “HVAC”.
| Work support items | Display | Setting |
|---|---|---|
| TARGET EVAPORATOR TEMP UPPER LIMIT SETTING | Initial setting | Setting 1 |
| Low | Setting 4 | |
| Middle (initial status) | Setting 3 | |
| High | Setting 2 |
| Setting | Target evaporator temperature upper limit value | Evaporator freezing protection control | Refrigerant discharge amount control |
|---|---|---|---|
| Setting 1 | 50°F (10°C) | Minimum operation ratio of compressor | Minimum refrigerant discharge amount |
| Setting 2 | 45°F (7°C) | Operation ratio of compressor increases from setting 1. | Refrigerant discharge amount increases from setting 1. |
| Setting 3 | 41°F (5°C) | Operation ratio of compressor increases from setting 2. | Refrigerant discharge amount increases from setting 2. |
| Setting 4 | 37°F (3°C) | Operation ratio of compressor increases from setting 3. | Refrigerant discharge amount increases from setting 3. |