Power Outlet - Dtc/circuit Diagnosis
- Power Supply and Ground Circuit
- Ac 120 V Power Output Circuit
Power Supply and Ground Circuit Nissan Pathfinder 2026
Diagnosis Procedure
CHECK FUSES
Check that the following fuses are not blown:
| Signal name | Fuse No. | Capacity |
|---|---|---|
| Battery power supply | 89 | 20 A |
| Ignition power supply | 4 | 10 A |
Is the fuse blown?
YES>>Replace the blown fuse after repairing the affected circuit.
NO>>GO TO 2.
CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Disconnect inverter unit connector.
Check voltage between inverter unit harness connector and ground.
(+) (-) Voltage
(Approx.)Inverter unit Connector Terminal B121 4 Ground Battery voltage
Is the inspection result normal?
YES>>GO TO 3.
NO>>Repair or replace the inverter unit power supply circuit.
CHECK INVERTER UNIT GROUND CIRCUIT
Check continuity between inverter unit harness connector and ground.
| Inverter unit | — | Continuity | |
|---|---|---|---|
| Connector | Terminal | ||
| B121 | 8 | Ground | Yes |
Is the inspection result normal?
YES>>Inspection End.
NO>>Repair or replace the inverter unit ground circuit.
Ac 120 V Power Output Circuit Nissan Pathfinder R53
Diagnosis Procedure
CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120 V OUTLET
Ignition switch OFF.
Disconnect inverter unit and AC 120 V outlet connectors.
Check continuity between inverter unit harness connector and AC 120 V outlet harness connector.
Inverter unit AC 120 V outlet Continuity Connector Terminal Connector Terminal B121 5 M88 1 Yes 1 4 Check continuity between inverter unit harness connector and ground.
Inverter unit — Continuity Connector Terminal B121 5 Ground No 1 Check continuity between inverter unit harness connector.
Inverter unit Continuity Connector Terminals B121 5 1 No
Is the inspection result normal?
YES>>GO TO 2.
NO>>Repair or replace the harness or connectors.
CHECK INVERTER UNIT OUTPUT SIGNAL
Connect inverter unit and AC 120 V outlet connector.
Ignition switch ON.
Check voltage between inverter unit harness connector.
Inverter unit Condition Voltage
(Approx.)Terminals (+) (-) Ignition ON. 5 1 OFF 0 V ON AC 120 V
Is the inspection result normal?
YES>>GO TO 3.
NO>>Replace inverter unit.
CHECK AC 120V OUTLET VOLTAGE
Check voltage between AC 120 V outlet.
| AC 120 V outlet | Condition | Voltage (Approx.) | |
|---|---|---|---|
| Terminals | |||
| (+) | (-) | Ignition ON. | |
| 1 | 4 | OFF | 0 V |
| ON | AC 120 V | ||
Is the inspection result normal?
YES>>GO TO 4.
NO>>Replace AC 120 V outlet.
CHECK AC 120V OUTLET GROUND CIRCUIT
Ignition switch OFF.
Disconnect AC 120 V outlet connector.
Check continuity between AC 120 V outlet harness connector and ground.
AC 120V outlet — Continuity Connector Terminal M88 3 Ground Yes
Is the inspection result normal?
YES>>Replace AC 120 V outlet.