Air conditioner compressor, R134a/R1234yf
- Assembly overview - air conditioner compressor
- Detaching and attaching refrigerant lines at air conditioner compressor
- Detaching/attaching air conditioner compressor [VX81] from/to bracket
Assembly overview - air conditioner compressor
- Air conditioner compressor - VX81-
- ⇒ Rep. gr. 87 ; Removing and installing air conditioner compressor [VX81]

- Electrical connector for high-voltage system
- ⇒ Electric drive motor; Rep. gr. 93 ; High-voltage cables; Overview of fitting locations - high-voltage cables
- Electrical connector
- Bolt
- 8 N·m
- Potential equalisation line
- ⇒ Electric drive motor; Rep. gr. 93 ; Potential equalisation lines; Overview of fitting locations - potential equalisation lines
- Bolt
- Qty. 3
- 20 N·m
- Retainer
- ⇒ Rep. gr. 87 ; Detaching and attaching air conditioner compressor at bracket
- Bolt
- Qty. 4
- 8 N·m
- Bolt
- Qty. 3
- 20 N·m
- Retainer
- ⇒ Rep. gr. 87 ; Detaching and attaching air conditioner compressor at bracket
Detaching and attaching refrigerant lines at air conditioner compressor
Special tools and workshop equipment required
- engine bung set - VAS 6122-
Detaching
Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .
- ⇒ General information - Air conditioners with refrigerant R134a/R1234yf; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
- Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .
CAUTION
Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body
- Put on protective gloves.
- Put on safety goggles.
- Extract/drain refrigerant and then immediately open up refrigerant circuit.
- Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
- Remove bolts -3- and detach refrigerant lines -2-.

Attaching
Installation is carried out in reverse order; note the following:
- ⇒ General information - Air conditioners with refrigerant R134a/R1234yf; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit .
Tightening torques
- ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
Removing and installing air conditioner compressor [VX81]
Special tools and workshop equipment required
- engine bung set - VAS 6122-
Removing
Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .
DANGER
High voltage can cause fatal injury.
Danger of severe or fatal injuries from electric shock or electric arcs.
- Have a high-voltage technician (HVT) or a high-voltage expert (HVE) de-energise the high-voltage system.
- ⇒ Rep. gr. 93 ; De-energise high-voltage system .
- ⇒ General information, air conditioning systems with refrigerant R134a/R1234yf; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
- Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake unit of heater and air conditioning unit .
- Disconnect electrical connectors -2-, and unclip electrical wires ⇒ Electric drive motor; Rep. gr. 93 ; High-voltage cables; Disconnecting high-voltage connectors .
- Unscrew bolts -3-.

- Unscrew bolt -4-.
CAUTION
Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body
- Put on protective gloves.
- Put on safety goggles.
- Extract/drain refrigerant and then immediately open up refrigerant circuit.
- Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.

- Unscrew bolts -3-, and pull off refrigerant lines.
- Remove air conditioner compressor - VX81- -1-.
If air conditioner compressor needs to be disconnected from bracket:
- ⇒ Rep. gr. 87 ; Detaching/attaching air conditioner compressor from/to bracket .
Installing
Install in reverse order of removal, observing the following:
When renewing air conditioner compressor:
Important
- The air conditioner compressor must not be flushed individually.
NOTICE
Risk of damage to components due to soiling.
- Keep the measuring beaker clean.
- Drain oil from removed air conditioner compressor into a measuring beaker -1- via the two connections to determine the amount of oil. Move the air conditioner compressor in a circular motion to ensure the best possible drainage.
- Check drained refrigerant oil for contamination.
Important
- Dark grey to black clouding indicates contamination.
Non-contaminated refrigeration oil:
- After removing protective caps on suction and pressure sides, drain oil from new air conditioner compressor into measuring beaker -2-. Move the air conditioner compressor in a circular motion to ensure the best possible drainage.
- The (drained) new air conditioner compressor must be filled with exact the same amount of refrigerant oil that has been determined in the removed air conditioner compressor (measuring beaker -2-). This is done via the suction pipe.
Continued
Contaminated refrigerant oil:
- ⇒ Rep. gr. 87 ; Clean refrigerant circuit .
Note
The new air conditioner compressor contains the amount of refrigeration oil required for the refrigerant circuit.
Continued
- Fit refrigerant lines -2-, and tighten bolts -3-.
- Check contact points of potential equalisation line, and clean them if necessary ⇒ Electrical system; Rep. gr. 97 ; Cleaning contact surfaces .
Important
- Contact surfaces must be free of dirt, rust and grease.
- Connect potential equalisation line, and tighten bolt -4-.

- ⇒ General information, air conditioning systems with refrigerant R134a/R1234yf; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .
WARNING
High voltage can cause fatal injury.
Danger of severe or fatal injuries from electric shock or electric arcs.
- Have a high-voltage technician (HVT) or a high-voltage expert (HVE) re-energise the high-voltage system.
- ⇒ Rep. gr. 93 ; Re-energising high-voltage system
After renewal of air conditioner compressor:
- Carry out function "Air conditioner compressor run-in" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
Continued
Tightening torques
- ⇒ Rep. gr. 87 ; Assembly overview - air conditioner compressor
- ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
Detaching/attaching air conditioner compressor [VX81] from/to bracket
Removing
- Remove air conditioner compressor - VX81- ⇒ Rep. gr. 87 ; Removing and installing air conditioner compressor [VX81] .
- Unscrew bolts -2-.
- Detach air conditioner compressor -3- from bracket -1-.
![Volkswagen ID.4. Detaching/attaching air conditioner compressor [VX81] from/to bracket](/media/volkswagen-id-4/353/images/manuals/353/volkswagen_id_4_detaching_attaching_air_conditioner_compressor_vx_602.webp)
Installing
Install in the reverse sequence of removal, observing the following:
Tightening torques
- ⇒ Rep. gr. 87 ; Assembly overview - air conditioner compressor