Refrigerant circuit, R744

In this manual: Refrigerant circuit, R744
Basic information on body repairs — 1Explanation of symbols — 1Overview of materials used — 1Joining and separating techniques — 1Surface repair — 1Corrosion protection — 1Noise insulation — 1Plastic repair — 1General notes - windows — 1Self-adhesive components — 1Noises — 1Resistance spot welding — 1Solid rivet — 1Pop rivet — 1Incorrect riveting — 1Overview of riveting attachments — 1Making a flow-drill screw connection, pre-drilled hole in upper part — 1Distinction of types of plastic — 1Processing instructions - original products — 1Preparing plastic repair — 1Repairing deformations — 1Bonding plastic attachments — 1Welding plastic attachments — 1Glass repair- Introduction — 1Carrying out glass repair — 1General notes on the use of adhesives — 1Preparing old undamaged windows for installing — 1Preparing new windows for installation — 1Installation instructions for bonded windows — 1Bonding log — 1Preparing gas strut for disposal — 1Preparing rear lid drive unit VX69/rear lid drive unit 2 VX77 for disposal — 1Causes of water ingress — 1Locating water ingress — 1Interior equipment — 1Compartments/covers — 1Equipment — 1Centre console — 1Front centre armrest — 1Interior mirror — 1Passenger protection — 1Seat belts — 1Child seat anchors — 1Airbag system — 1Airbag control unit — 1Front airbag, driver side — 1Front passenger airbag — 1Side airbags — 1Curtain airbags — 1Airbag crash sensors — 1Seat belt verification — 1Seat occupied recognition — 1Trim, insulation — 1Front door trims — 1Rear door trims — 1Dash panel — 1Central tube for dash panel — 1Interior trims — 1Luggage compartment trims — 1Roof trims — 1Seat frames — 1Overview of seat variants — 1Front seats — 1Rear seats — 1Seat - padding, covers — 1Front seat covers and padding — 1Rear seat covers and padding — 1Technical data — 1Body - front — 1Lock carrier — 1Wings — 1Technical data — 1Air conditioning system — 1Overview of fitting locations - air conditioning system, R134a/R1234yf — 1Overview of fitting locations - air conditioning system, R744 — 1Refrigerant circuit, R134a/R1234yf — 1Refrigerant circuit, R744 — 1Valve unit of heat pump, R744 — 1Air conditioner compressor, R134a/R1234yf — 1Air conditioner compressor, R744 — 1Control motors, vehicles without air conditioner operating unit at rear — 1Control motors, vehicles with air conditioner operating unit at rear — 1Front heater and air conditioning unit, R134a/R1234yf — 1Front heater and air conditioning unit, R744 — 1Air duct — 1Coolant circuit, rear-wheel drive — 1Coolant circuit, all-wheel drive — 1Operating and display unit — 1Other controlling and regulating components — 1Air quality improvement system — 1Technical data — 1Brake test — 1Electrical components — 1Anti-lock brake system — 1Control unit and hydraulic unit — 1Separating control unit from and connecting to hydraulic unit — 1Connecting brake lines to hydraulic unit — 1Sensors — 1Brakes - mechanism — 1Front brake — 1Rear brake — 1Parking brake — 1Brake pedal — 1Brakes - hydraulics — 1Brake servo and brake master cylinder — 1Hydraulic system — 1Technical data — 1Fitting locations — 1Senders/sensors/control units — 1Adaptive cruise control — 1Reversing camera system — 1Front camera for driver assist systems — 1Overhead view camera — 1Electric drive systems- Safety information and repair notes — 1Classifying high-voltage batteries — 1Packaging high-voltage batteries — 1Packaging critical high-voltage batteries with "Warning" status — 1Bulkhead — 1Bonnet, rear lid — 1Bonnet — 1Rear lid — 1Charging flap unit — 1Front doors, door components, central locking — 1Door — 1Door components — 1Central locking — 1Rear doors, door components — 1Door — 1Door components — 1Sunroof — 1Sliding sunroof — 1Water drain hoses — 1Bumpers — 1Bumper, front — 1Bumper, rear — 1Glazing — 1Windscreen — 1Rear windscreen — 1Side windows — 1Door windows — 1Exterior equipment — 1Spoiler — 1Mouldings, trims, extensions — 1Underbody cladding — 1Roof moulding and roof railing — 1Exterior mirror — 1Wheel housing liner — 1Lettering and emblems — 1Towing bracket — 1Technical data — 1Vehicle identification data — 1Safety information — 1Body parts and materials — 1Technical data — 1Alignment jig — 1Body - front — 1Overview of fitting locations — 1Longitudinal member cross panel — 1Longitudinal member — 1Assembly overview - front right longitudinal member, part section — 1Battery tray — 1Front wheel housing — 1Body - centre — 1Overview of fitting locations — 1Roof — 1A-pillar — 1B-pillar — 1Side member — 1Body - rear — 1Rear cross member — 1Rear cross panel — 1Luggage compartment floor — 1Rear longitudinal member — 1Side panel — 1Rear wheel housing — 1Technical data — 1Controls, housing — 1Removing and installing gearbox — 1Gearbox housing, clutch housing — 1Final drive - differential — 1Technical data — 1Controls, housing — 1Gearbox housing, clutch housing — 1Gear oil — 1Final drive - differential — 1Explanation of symbols — 1Paintwork structure — 1Areas exposed to stone chipping — 1Seam seals, front body — 1Seam seals, bonnet, inner side — 1Seam seals, doors — 1Seam seals, underbody — 1Underseal — 1Cavity sealing — 1Technical data — 1Overview of fitting locations - components/control units in centre section of vehicle — 1Overview of fitting locations - components/control units in rear section of vehicle — 1Overview of fitting locations - components/control units in centre section of vehicle — 1Overview of fitting locations - components/control units in rear section of vehicle — 1Components/control units — 1Multifunction steering wheel — 1Technical data — 1Identification — 1Electrical components — 1Hazard classification of high-voltage system — 1Removing and installing engine — 1Removing and installing front motor — 1Removing and installing rear motor — 1Removing and installing rear motor — 1Front assembly mountings — 1Cooling — 1Cooling system/coolant — 1Coolant pump/coolant regulation — 1Radiator, radiator fan — 1Electric drive systems — 1High-voltage components, charging unit for high-voltage battery and voltage converter — 1High-voltage components, charging unit for high-voltage battery with integrated voltage converter — 1Warning stickers — 1High-voltage battery unit, edge of upper part of battery housing without wax — 1High-voltage battery components, edge of upper part of battery housing without wax — 1High-voltage battery unit, edge of upper part of battery housing with wax — 1High-voltage battery components, edge of upper part of battery housing with wax — 1Power and control electronics for electric drive — 1Electric drive motor — 1Electric drive motor — 1Motor control unit — 1De-energising high-voltage system — 1Potential equalisation lines — 1Charging socket, with charging cable — 1Charging socket, with separate charging cable — 1Charging unit for high-voltage battery — 1Charging unit for high-voltage battery, with integrated voltage converter — 1Vehicle noise/engine sound — 1Accelerator pedal — 1Voltage converter — 1High-voltage cables, all-wheel drive — 1High-voltage cables, rear-wheel drive — 1Technical data — 1Starter, current supply, CCS — 1Assembly overview - battery — 1Removing and installing battery [A] — 1Disconnecting and connecting battery — 1Removing and installing earth wire with battery monitor control unit [J367] — 1Gauges, instruments — 1Dash panel insert — 1Horn — 1Windscreen wash/wipe system — 1Windscreen wiper system — 1Windscreen washer system — 1Rear window wiper system ID4 — 1Rear window washer system — 1Lights, bulbs, switches - exterior — 1Headlights — 1Lights in exterior mirror — 1Tail lights — 1High-level brake light — 1Number plate light — 1Entry and start authorisation system — 1Steering column switch module — 1Towing bracket — 1Lights, bulbs, switches - interior — 1Lights — 1Controls — 1Anti-theft alarm system — 1Cigarette lighter, socket — 1Wiring — 1Relay carriers, fuse holders, electronics boxes — 1Control units — 1Technical data — 1Front suspension — 1Front axle — 1Subframe — 1Suspension strut, upper suspension link — 1Lower suspension link, swivel joint — 1Wheel bearing — 1Drive shaft — 1Anti-roll bar — 1Rear suspension — 1Rear axle — 1Subframe — 1Anti-roll bar — 1Suspension link, track rod — 1Suspension strut, shock absorber, spring — 1Wheel bearing assembly, trailing arm — 1Drive shaft — 1Self-levelling suspension — 1Electronic damping control — 1Vehicle level sender — 1Wheels, tyres, vehicle geometry — 1Wheel alignment — 1Wheels, tyres — 1Steering — 1Steering wheel — 1Steering column — 1Steering rack — 1
2steps
~12min
1/5difficulty
010203040501310N·mlb·ft
Tightening torque found on this page
Done 0 of 2
  • System overview - refrigerant circuit
  • Assembly overview - refrigerant lines
  • Removing and installing refrigerant pressure and temperature sender G395
  • Removing and installing gas cooler
  • Removing and installing dryer in receiver
  • Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)
  • Removing and installing refrigerant pressure and temperature sender 2 G826
  • Removing and installing refrigerant pressure and temperature sender 3 G827
  • Removing and installing refrigerant pressure and temperature sender 5 [G829]
  • Removing and installing pressure limiting valve
  • Removing and installing heat exchanger for high-voltage battery
  • Removing and installing refrigerant lines
  • Removing and installing refrigerant line between refrigerant shut-off valve 3 N641 and heat condenser
  • Removing and installing refrigerant line between expansion valve N638/N637 and evaporator
  • Removing and installing refrigerant line between heat pump valve unit and evaporator
  • Removing and installing refrigerant line between expansion valve N636/N696 and heat condenser
  • Disconnecting and connecting refrigerant lines on gas cooler
  • Cleaning refrigerant circuit

System overview - refrigerant circuit

  1. Gas cooler
  • ⇒ Rep. gr. 87 ; Removing and installing gas cooler
  1. Refrigerant shut-off valve 1 - N696-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 1 N696
  1. Integration into coolant circuit for high-voltage battery
  • ⇒ Electric drive motor; Rep. gr. 19 ; Cooling system/coolant; Connection diagram - coolant hoses
  1. High-voltage battery heat exchanger
  • ⇒ Rep. gr. 87 ; Removing and installing heat exchanger for high-voltage battery
  1. Service connection (lowpressure side)
  • ⇒ Rep. gr. 87 ; Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)
  1. Service connection (highpressure side)
  • Low pressure may occur at the high-pressure side of the service connection depending on the valve positions and the associated operating states
  • ⇒ Rep. gr. 87 ; Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)
Volkswagen ID.4.  System overview - refrigerant circuit
  1. Refrigerant expansion valve 2 - N637-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant expansion valve 2 N637
  1. Refrigerant expansion valve 3 - N638-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant expansion valve 3 N638
  1. Refrigerant pressure and temperature sender 4 - G828-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 4 G828
  1. Heat condenser
  • ⇒ Rep. gr. 87 ; Removing and installing heat condenser
  1. Refrigerant expansion valve 1 - N636-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant expansion valve 1 N636
  1. Evaporator
  • ⇒ Rep. gr. 87 ; Removing and installing evaporator
  1. Refrigerant shut-off valve 4 - N642-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 4 N642
  1. Refrigerant pressure and temperature sender 2 - G826-
  • Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 2 G826
  1. Refrigerant shut-off valve 3 - N641-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 3 N641
  1. Dryer with internal heat exchanger
  • ⇒ Rep. gr. 87 ; Removing and installing dryer
  1. Refrigerant pressure and temperature sender 5 - G829-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 5 G829
  1. Air conditioner compressor - VX81-
  • ⇒ Rep. gr. 87 ; Removing and installing air conditioner compressor VX81
  1. Refrigerant pressure and temperature sender - G395-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender G395
  1. Refrigerant shut-off valve 2 - N640-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 2 N640
  1. Refrigerant shut-off valve 5 - N643-
  • Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 5 N643
  1. Refrigerant pressure and temperature sender 3 - G827-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 3 G827

Assembly overview - refrigerant lines

  1. Bolt
  • Applies to all connections in illustration
  • Renew after removing
  • Hexagon bolt: 13 N·m
  • Twelve-point bolt: 5 N·m +90º
  1. Seal
  • Applies to all connections in illustration
  • Renew after removing
  1. Retaining element
  • Applies to all connections in illustration
  • Renew after removing
  1. Seal
  • Applies to all refrigerant pressure and temperature senders shown
  • Renew after removing
  1. Dust ring
  • Applies to all refrigerant pressure and temperature senders shown
  • Renew after removing
  1. Refrigerant pressure and temperature sender 2 - G826-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 2 G826
  • 40 N·m
Volkswagen ID.4. Assembly overview - refrigerant lines
  1. Heat pump valve unit
  • ⇒ Rep. gr. 87 ; Assembly overview - heat pump valve unit
  • ⇒ Rep. gr. 87 ; Removing and installing heat pump valve unit
  1. Pressure relief valve
  • Left-hand thread
  • Renew after removing
  • ⇒ Rep. gr. 87 ; Removing and installing pressure relief valve
  • 14 N·m
  1. Evacuating and charging valve
  • ⇒ Rep. gr. 87 ; Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)
  • 2 N·m
  1. Valve cap
  2. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between refrigerant shut-off valve 3 N641 and heat condenser
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between expansion valve N638/N637 and evaporator
  1. Refrigerant pressure and temperature sender 4 - G828-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 4 G828
  • 40 N·m
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between heat pump valve unit and evaporator
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between expansion valve N636/N696 and heat condenser
  1. Refrigerant pressure and temperature sender - G395-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender G395
  • 40 N·m
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between air conditioner compressor VX81 and valve block N641/N640
  1. Air conditioner compressor - VX81-
  • ⇒ Rep. gr. 87 ; Assembly overview - air conditioner compressor
  • ⇒ Rep. gr. 87 ; Removing and installing air conditioner compressor VX81
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 N640
  1. Refrigerant pressure and temperature sender 3 - G827-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 3 G827
  • 40 N·m
  1. Gas cooler
  • ⇒ Rep. gr. 87 ; Removing and installing gas cooler
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between dryer and gas cooler
  1. Refrigerant line
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant line between air conditioner compressor and dryer
  1. Refrigerant pressure and temperature sender 5 - G829-
  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant pressure and temperature sender 5 G829
  • 40 N·m

Removing and installing refrigerant pressure and temperature sender G395

Special tools and workshop equipment required

  • engine bung set - VAS 6122-
  • socket - T40284-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Unclip coolant hoses -1- and push them to side.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender G395
  • Mark electrical connector -5- to avoid interchange and unplug it.
  • Check refrigerant line connection -1- and refrigerant pressure and temperature sender - G395- -4- for dirt and clean if necessary.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew sender -4- using socket - T40284- ; counterhold at refrigerant line -1- using open-end spanner while doing so.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender G395
  • Mark electrical connector -5- to avoid interchange and unplug it.
  • Check refrigerant line connection -1- and refrigerant pressure and temperature sender - G395- -4- for dirt and clean if necessary.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew sender -4- using socket - T40284- ; counterhold at refrigerant line -1- using open-end spanner while doing so.

Installing

Installation is carried out in reverse order; note the following:

  • Install seals, making sure they are free of oil.
  • Check that refrigerant lines are seated correctly and tighten refrigerant pressure and temperature sender - G395- ; counterhold using open-end spanner while doing so.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing gas cooler

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

When renewing gas cooler:

  • Observe procedure for renewing components in refrigerant circuit ⇒ General information - air conditioning systems with refrigerant R744; Rep. gr. 87 ; Renewing components; Renewing components .

Continued

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Disconnect refrigerant lines from gas cooler ⇒ Rep. gr. 87 ; Disconnecting and connecting refrigerant lines of gas cooler .
  • Dismantle radiator module ⇒ Rep. gr. 19 ; Radiator/radiator fan; Dismantling and assembling radiator module .

Installing

Install in reverse order of removal, observing the following:

  • Install seals and captive fasteners free of oil.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing dryer in receiver

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove heat pump valve unit ⇒ Rep. gr. 87 ; Removing and installing heat pump valve unit .
  • Unscrew bolts -1- and -2-.
Volkswagen ID.4. Removing and installing dryer in receiver
  • Unscrew bolts -1-, -2- and -3-.
Volkswagen ID.4. Removing and installing dryer in receiver
  • Pull off refrigerant lines -1- and -2-.
Volkswagen ID.4. Removing and installing dryer in receiver
  • Unscrew nut -2-.
  • Pull dryer -1- upwards out of bracket.
Volkswagen ID.4. Removing and installing dryer in receiver

Installing

Install in reverse order of removal, observing the following:

When renewing dryer:

  • Observe procedure for renewing components in refrigerant circuit ⇒ General information - air conditioning systems with refrigerant R744; Rep. gr. 87 ; Renewing components .

Continued

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - heat pump valve unit

Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)

Special tools and workshop equipment required

  • engine bung set - VAS 6122-
  • socket - T10364/5-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Detach protective cap -3-.
Volkswagen ID.4. Removing and installing evacuating and charging valve (low-pressure and high-pressure sides)

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove valve core -2- using socket - T10364/5- .

Installing

Installation is carried out in reverse order; note the following:

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant pressure and temperature sender 2 G826

Special tools and workshop equipment required

  • engine bung set - VAS 6122-
  • socket - T40284-

Available versions

Variante A - up to approx. 10/2023, identifiable by pressure sender aligned horizontally in refrigerant line -1-

Variante B - as of approx. 11/2023, identifiable by pressure sender aligned vertically -2-

Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 2 G826

Removing and installing, version A

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove lock carrier ⇒ General body repairs, exterior; Rep.

    gr. 50 ; Lock carrier; Removing and installing lock carrier .

  • Detach coolant expansion tank, and lay it aside ⇒ Rep.

    gr. 19 ; Cooling system/coolant; Removing and installing coolant expansion tank .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew bolts -1-.
  • Pull off and remove refrigerant line -2-.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 2 G826
  • Disconnect electrical connector -5-.
  • Check connection of refrigerant line -1- and refrigerant pressure and temperature sender 2 - G826- -4- for contamination and clean.
  • Unscrew sender -4- using socket - T40284- while counterholding at refrigerant line -1- with open-end spanner.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 2 G826

Installing

Install in reverse order of removal, observing the following:

  • Install seals and captive fasteners free of oil.
  • Make sure that refrigerant lines are seated correctly, and tighten refrigerant pressure and temperature sender 2 - G826- while counterholding with open-end spanner.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
  • ⇒ Rep. gr. 87 ; Assembly overview - heat pump valve unit

Removing and installing, version B

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Detach coolant expansion tank, and lay it aside ⇒ Rep.

    gr. 19 ; Cooling system/coolant; Removing and installing coolant expansion tank .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Check connection of refrigerant line -1- and refrigerant pressure and temperature sender 2 - G826- -2- for contamination and clean.
  • Disconnect electrical connector -3-.
  • Unscrew sender -2- using socket - T40284- .
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 2 G826

Installing

Install in reverse order of removal, observing the following:

  • Install seals free of oil.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant pressure and temperature sender 3 G827

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit
  • Remove front underbody cladding ⇒ General body repairs, exterior; Rep. gr. 66 ; Underbody cladding; Removing and installing front underbody cladding .
  • Unplug electrical connector -1-.
  • Check connection of refrigerant line -5- and refrigerant pressure and temperature sender 3 - G827- -2- for dirt and clean if necessary.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 3 G827

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew refrigerant pressure and temperature sender 3 - G827- -2- while counterholding at refrigerant line using open-end spanner.

Installing

Installation is carried out in reverse order; note the following:

  • Install seals, making sure they are free of oil.
  • Check that refrigerant lines are seated correctly and tighten refrigerant pressure and temperature sender 3 - G827- ; counterhold using open-end spanner while doing so.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant pressure and temperature sender 4 G828

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .

CAUTION

The cooling system may be under pressure. Risk of scalding due to hot steam and hot coolant Danger of scalding skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Cover filler cap on expansion tank with a suitable cloth and open carefully to release pressure.
  • Unfasten coolant expansion tank and move to side ⇒ Rep.

    gr. 19 ; Cooling system/coolant; Removing and installing coolant expansion tank .

  • Unplug electrical connector -5-.
  • Check connection of refrigerant line -1- and refrigerant pressure and temperature sender 4 - G828- -4- for dirt and clean if necessary.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 3 G827

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew refrigerant pressure and temperature sender 4 - G828- -4- while counterholding at refrigerant line using open-end spanner.

Installing

Installation is carried out in reverse order; note the following:

  • Install seals, making sure they are free of oil.
  • Check that refrigerant lines are seated correctly and tighten refrigerant pressure and temperature sender 4 - G828- ; counterhold using open-end spanner while doing so.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant pressure and temperature sender 5 [G829]

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove air conditioner compressor - VX81- ⇒ Rep. gr. 87 ; Removing and installing air conditioner compressor [VX81] .
  • Disconnect electrical connector -5-.
  • Check connection of refrigerant line -1- and refrigerant pressure and temperature sender 5 - G829- -4- for contamination and clean.
Volkswagen ID.4. Removing and installing refrigerant pressure and temperature sender 5 [G829]

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew refrigerant pressure and temperature sender 5 - G829- -4- while counterholding at refrigerant line with openend spanner.

Installing

Install in reverse order of removal, observing the following:

  • Install seals free of oil.
  • Make sure that refrigerant lines are seated correctly, and tighten refrigerant pressure and temperature sender 5 - G829- while counterholding with open-end spanner.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
  • ⇒ Rep. gr. 87 ; Assembly overview - drive unit of air conditioner compressor

Removing and installing pressure limiting valve

Special tools and workshop equipment required

  • ESD workplace - VAS 6613-

Removing

  • Remove heat pump valve unit ⇒ Rep. gr. 87 ; Removing and installing heat pump valve unit .

NOTICE

Risk of damage to electrical components.

Electrostatic charge may damage electrical components.

  • Work on electrical components must always be carried out at an ESD workplace.
  • Place heat pump valve unit on ESD workplace - VAS 6613- .

Remove pressure limiting valve on valve block for refrigerant expansion valve 2 - N637- and refrigerant expansion valve 3 - N638- :

  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant expansion valve 2 N637

Continued

Remove pressure limiting valve on valve block for refrigerant shut-off valve 4 - N642- and refrigerant shut-off valve 5 - N643- :

  • ⇒ Rep. gr. 87 ; Removing and installing refrigerant shut-off valve 4 N642

Continued

  • Check area around pressure limiting valve -2- for dirt and clean it.
  • Unscrew pressure limiting valve -2- from valve block -1-.

Note

The pressure limiting valve has a left-hand thread.

Volkswagen ID.4. Removing and installing pressure limiting valve

Installing

Installation is carried out in reverse order; note the following:

  • Before installing, check protective film -3- on pressure limiting valve -2- for damage.

Important

  • Pressure limiting valves with damaged protective film must not be fitted.
Volkswagen ID.4. Removing and installing pressure limiting valve
  • Install seals and retaining elements, making sure they are free of oil.

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
  • ⇒ Rep. gr. 87 ; Assembly overview - heat pump valve unit

Removing and installing heat exchanger for high-voltage battery

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .

If heat exchanger is renewed:

  • Observe procedure for renewing components in refrigerant circuit ⇒ General information - air conditioning systems with refrigerant R744; Rep. gr. 87 ; Renewing components .

Continued

  • Remove dryer ⇒ Rep. gr. 87 ; Removing and installing dryer .
  • Before dismantling the heat pump valve unit, mark electrical connectors and refrigerant lines accordingly.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew bolts -1-, -2-, -3- and -4-.
  • Pull off refrigerant lines.
Volkswagen ID.4. Removing and installing heat exchanger for high-voltage battery
  • Unscrew bolts -1-.
  • Disconnect electrical connectors.
  • Remove heat exchanger -2-.
Volkswagen ID.4. Removing and installing heat exchanger for high-voltage battery

Installing

Install in reverse order of removal, observing the following:

  • Install seals and captive fasteners free of oil.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - heat pump valve unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing heat condenser

  • Heat condenser is currently not available as a separate part ⇒ Electronic parts catalogue (ETKA) .

Removing and installing refrigerant lines

Removing and installing refrigerant line between air conditioner compressor and dryer

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .
  • Remove front underbody cladding ⇒ General body repairs, exterior; Rep. gr. 66 ; Underbody cladding; Removing and installing front underbody cladding .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew bolt -3- securing refrigerant line from air conditioner compressor - VX81- to expansion valve.
Volkswagen ID.4. Removing and installing refrigerant line between air conditioner compressor and dryer
  • Remove bolt -3- securing refrigerant line -2-.
  • Detach refrigerant line -2-.
Volkswagen ID.4. Removing and installing refrigerant line between air conditioner compressor and dryer
  • Unplug electrical connector -5-.
Volkswagen ID.4. Removing and installing refrigerant line between air conditioner compressor and dryer
  • Remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between air conditioner compressor and dryer

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Disconnecting and connecting refrigerant lines on gas cooler

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .
  • Remove front underbody cladding ⇒ General body repairs, exterior; Rep. gr. 66 ; Underbody cladding; Removing and installing front underbody cladding .
  • Unplug electrical connector -3-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit
Volkswagen ID.4. Disconnecting and connecting refrigerant lines on gas cooler

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
  • ⇒ Rep. gr. 87 ; Assembly overview - air conditioner compressor

Removing and installing refrigerant line between dryer and gas cooler

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove front underbody cladding ⇒ General body repairs, exterior; Rep. gr. 66 ; Underbody cladding; Removing and installing front underbody cladding .
  • Unplug electrical connector -4-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between dryer and gas cooler
  • Unplug electrical connector -4-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines
  • ⇒ Rep. gr. 87 ; Assembly overview - air conditioner compressor

Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 [N640]

Special tools and workshop equipment required

  • counterhold tool - T10630-
  • engine bung set - VAS 6122-

Available versions

Variante A - up to approx. 10/2023, identifiable by pressure sender aligned horizontally in refrigerant line -1-

Variante B - as of approx. 11/2023, identifiable by pressure sender aligned vertically -2-

Volkswagen ID.4. Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 [N640]

Removing and installing, version A

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake unit of heater and air conditioning unit .
  • Remove lock carrier ⇒ General body repairs, exterior; Rep.

    gr. 50 ; Lock carrier; Removing and installing lock carrier .

  • Insert counterhold tool - T10630- -3-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
Volkswagen ID.4. Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 [N640]
  • Unscrew bolts -2-.
  • Pull off and remove refrigerant line -1-.

Installing

  • Install seals and captive fasteners free of oil.
  • When tightening bolts -2-, use counterhold tool - T10630- .
Volkswagen ID.4. Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 [N640]
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing, version B

Removing

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake unit of heater and air conditioning unit .
  • Remove lock carrier ⇒ General body repairs, exterior; Rep.

    gr. 50 ; Lock carrier; Removing and installing lock carrier .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew bolts -2-.
  • Pull off and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between gas cooler and refrigerant shut-off valve 2 [N640]

Installing

Install in reverse order of removal, observing the following:

  • Install seals and captive fasteners free of oil.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant line between refrigerant shut-off valve 3 N641 and heat condenser

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between refrigerant shut-off valve 3 N641 and heat condenser

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant line between expansion valve N638/N637 and evaporator

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .
  • Unplug electrical connector -3-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
Volkswagen ID.4. Removing and installing refrigerant line between expansion valve N638/N637 and evaporator
  • Unplug electrical connector -3-.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant line between heat pump valve unit and evaporator

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Identifying version

Variante A - Up to approx. 10.2023 - can be identified by horizontally positioned pressure sender in refrigerant line -1- Variante B - From approx. 11.2023 onwards - can be identified by vertically positioned pressure sender -2-

Volkswagen ID.4. Removing and installing refrigerant line between heat pump valve unit and evaporator

Removing and installing version A

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between heat pump valve unit and evaporator

Installing

Installation is carried out in reverse order; note following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing version B

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between heat pump valve unit and evaporator

Installing

Installation is carried out in reverse order; note following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Removing and installing refrigerant line between expansion valve N636/N696 and heat condenser

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Removing

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Discharging refrigerant circuit .
  • Remove air intake box of heater and air conditioning unit ⇒ Rep. gr. 87 ; Removing and installing air intake box of heater and air conditioning unit .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Remove bolts -2-.
  • Detach and remove refrigerant line -1-.
Volkswagen ID.4. Removing and installing refrigerant line between expansion valve N636/N696 and heat condenser

Installing

Installation is carried out in reverse order; note the following:

  • Install seals and retaining elements, making sure they are free of oil.
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating and charging" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • ⇒ Air conditioners with refrigerant R744 - General information; Rep. gr. 87 ; Working with the air conditioner service station; Charging refrigerant circuit

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - air intake box of heater and air conditioning unit
  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Disconnecting and connecting refrigerant lines on gas cooler

Special tools and workshop equipment required

  • engine bung set - VAS 6122-

Disconnecting

Immediately seal open lines and connections with clean plugs from engine bung set - VAS 6122- .

  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Draining refrigerant circuit .
  • Remove lock carrier ⇒ General body repairs, exterior; Rep.

    gr. 50 ; Lock carrier; Removing and installing lock carrier .

  • Remove front underbody cladding ⇒ General body repairs, exterior; Rep. gr. 66 ; Underbody cladding; Removing and installing front underbody cladding .

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Unscrew bolt -1-.
  • Pull off refrigerant line -2-.
Volkswagen ID.4. Disconnecting and connecting refrigerant lines on gas cooler
  • Unscrew bolt -1-.
  • Pull off refrigerant line -2-.
Volkswagen ID.4. Disconnecting and connecting refrigerant lines on gas cooler

Connecting

Install in reverse order of removal, observing the following:

  • Install seals and captive fasteners free of oil.
  • Carry out function "Open electrically actuated valves to drain, evacuate or charge refrigerant circuit" using ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Access to diagnoses .
  • ⇒ Air conditioning systems with refrigerant R744 - General notes; Rep. gr. 87 ; Working with air conditioner service station; Charging refrigerant circuit .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines

Cleaning refrigerant circuit

Special tools and workshop equipment required

  • Air conditioner service station
  • air conditioner service station
  • engine bung set - VAS 6122-
  • flushing adapter - VAS 6338/77-
  • flushing adapter - VAS 6338/78-
  • flushing device
  • The refrigerant circuit is flushed using refrigerant R1234yf and the air conditioner service station which is designed for this purpose.
  • The following procedure is described for an air conditioner service station with integrated flushing device for R1234yf as an example.
  • If the refrigerant circuit is contaminated, it is flushed in the same direction as the normal direction of flow.
  • There must be at least 6 kg of refrigerant in the air conditioner service station.
  • Observe operating instructions for air conditioner service station ⇒ Operating instructions .

Procedure

Seal open lines and connections immediately with clean plugs from engine bung set - VAS 6122- .

  • Detach refrigerant lines from air conditioner compressor ⇒ Rep. gr. 87 ; Detaching and attaching refrigerant lines at air conditioner compressor .
  • Unplug electrical connector -1- on refrigerant pressure and temperature sender - G395- -2-.
Volkswagen ID.4. Cleaning refrigerant circuit
  • Connect low-pressure hose -1- of air conditioner service station to flushing device -3- of air conditioner service station with quick-release coupling -2-.
Volkswagen ID.4. Cleaning refrigerant circuit
  • Screw refrigerant line (high-pressure side) -4- to flushing adapter - VAS 6338/77- -3-.
  • Screw refrigerant line (low-pressure side) -5- to flushing adapter - VAS 6338/78- -6-.
  • Screw refrigerant hose -7- of flushing device to flushing adapter - VAS 6338/78- -6-.
  • Connect refrigerant hose -2- of air conditioner service station to flushing adapter - VAS 6338/77- -3-.
Volkswagen ID.4. Cleaning refrigerant circuit
  • Perform function "Opening electrically actuated valves in refrigerant circuit for extracting, evacuating, charging and flushing" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .
  • Start flushing procedure via menu of air conditioner service station ⇒ Operating instructions .

Important

  • Air conditioner service station displays when flushing procedure has been completed.

CAUTION

Risk of frostbite from escaping pressurised refrigerant Risk of frostbite on skin and other parts of the body

  • Put on protective gloves.
  • Put on safety goggles.
  • Extract/drain refrigerant and then immediately open up refrigerant circuit.
  • Extract/drain refrigerant again if more than 10 minutes have passed since initial extraction and refrigerant circuit has not been opened up. Renewed evaporation has created pressure in the refrigerant circuit.
  • Check pressure in flushing circuit; only detach refrigerant hoses and adapters if pressure is below or equal to ambient pressure.
  • Disconnect air conditioner service station and detach adapter.
  • After charging refrigerant circuit and re-energising high-voltage system, perform "Compressor activation" with ⇒ Vehicle diagnostic tester ⇒ Rep. gr. 00 ; Starting diagnosis .

Tightening torques

  • ⇒ Rep. gr. 87 ; Assembly overview - refrigerant lines