Symptom Diagnosis
- Automatic Air Conditioning System Symptoms
- Insufficient Cooling
- Insufficient Heating
- Electric Compressor Does Not Operate
Automatic Air Conditioning System Symptoms Nissan Ariya
Symptom Table
| Symptom | Corresponding malfunction part | Check item/Reference | ||
|---|---|---|---|---|
Air conditioning system does not activate. |
|
Check A/C auto amp. power supply or ground circuit. Refer to Diagnosis Procedure. |
||
| Air conditioning cannot be controlled. | Display operation | Check AV system Refer to Work Flow. |
||
| A/C control | All control |
|
Check A/C control power supply and ground circuit. Refer to Diagnosis Procedure. |
|
| A part of control | A/C control | Replace A/C control. Refer to Removal & Installation. |
||
| Discharge air temperature does not change. | Driver side | Air mix door motor (driver side) system installation condition | Check air mix door motor (driver side) system is properly installed. Refer to Exploded View. |
|
| Passenger side | Air mix door motor (passenger side) system installation condition | Check air mix door motor (passenger side) system is properly installed. Refer to Exploded View. |
||
| Air outlet does not change. | Front | Driver side | Front mode door motor (driver side) system installation condition | Check front mode door motor (driver side) system is properly installed. Refer to Exploded View. |
| Passenger side | Front mode door motor (passenger side) system installation condition | Check front mode door motor (passenger side) system is properly installed. Refer to Exploded View. |
||
| Rear | Rear mode door motor system installation condition | Check rear mode door motor system is properly installed. Refer to Exploded View. |
||
| Air inlet does not change. | Intake door motor system installation condition | Check intake door motor system is properly installed. Refer to Exploded View. |
||
| Blower motor does not operates or operation speed is not normal. |
|
Check blower motor circuit. Refer to Diagnosis Procedure. |
||
| Electric compressor does not operate. |
|
Refer to Diagnosis Procedure. | ||
|
|
Refer to Diagnosis Procedure. | ||
|
|
Refer to Diagnosis Procedure. | ||
| Noise is heard when the air conditioning operates. | During electric compressor operation | Cooler cycle | Symptom table for noise Refer to Symptom Table. |
|
| During blower motor operation |
|
Check blower motor. Refer to Component Inspection. |
||
Insufficient Cooling Nissan Ariya 1st generation
Diagnosis Procedure
Symptom
Insufficient cooling
No cold air comes out. (Air flow volume is normal.)
CHECK REFRIGERANT CYCLE
Connect recovery/recycling/recharging equipment (for HFO-1234yf) to the Nissan Ariya vehicle and perform the refrigerant system diagnosis. Refer to Symptom Table.
Is the check result normal?
YES>>GO TO 2.
NO>>Repair or replace malfunctioning part according to diagnosis result.
CHECK FOR AIR LEAKAGE FROM DUCT
Check duct and nozzle, etc. of A/C system for air leakage.
Is the check result normal?
YES>>GO TO 3.
NO>>Repair or replace parts according to the inspection results.
CHECK SETTING OF DIFFERENCE BETWEEN SET TEMPERATURE AND CONTROL TEMPERATURE
With CONSULT
Using CONSULT, check the setting of “Temperature setting correct” on “Work support” of “HVAC”. Refer to CONSULT Function.
Check that the difference between set temperature and control temperature is set to “+ direction”.
Change the set temperature correction value to “0”.
Are the symptoms solved?
YES>>Perform the setting separately if necessary. Inspection end.
NO>>Replace A/C auto amp. Refer to Removal & Installation.
Insufficient Heating Nissan Ariya first Gen
Diagnosis Procedure
Symptom
Insufficient heating
No warm air comes out. (Air flow volume is normal.)
CHECK REFRIGERANT CYCLE
Connect recovery/recycling/recharging equipment (for HFO-1234yf) to the Nissan Ariya vehicle and perform the refrigerant system diagnosis. Refer to Symptom Table.
Is the check result normal?
YES>>GO TO 2.
NO>>Repair or replace malfunctioning part according to diagnosis result.
CHECK FOR AIR LEAKAGE FROM DUCT
Check duct and nozzle, etc. of A/C system for air leakage.
Is the check result normal?
YES>>GO TO 3.
NO>>Repair or replace malfunctioning part according to diagnosis result.
CHECK SETTING OF DIFFERENCE BETWEEN SET TEMPERATURE AND CONTROL TEMPERATURE
With CONSULT
Using CONSULT, check the setting of “Temperature setting correct” on “Work support” of “HVAC”. Refer to CONSULT Function.
Check that the difference between set temperature and control temperature is set to “− direction”.
Change the set temperature correction value to “0”.
Are the symptoms solved?
YES>>Perform the setting separately if necessary. Inspection end.
NO>>GO TO 4.
CHECK HIGH VOLTAGE JUNCTION BOX
Check high voltage junction box. Refer to Component Inspection.
Is the inspection result normal?
YES>>Replace A/C auto amp. Refer to Removal & Installation.
NO>>GO TO 5.
CHECK PTC HEATER
Check PTC heater. Refer to Component Inspection.
Is the inspection result normal?
YES>>Replace high voltage junction box. Refer to HIGH VOLTAGE JUNCTION BOX : Disassembly & Assembly.
NO>>Replase PTC heater (refer to Removal & Installation.), and then replace high voltage junction box. Refer to HIGH VOLTAGE JUNCTION BOX : Disassembly & Assembly.
Electric Compressor Does Not Operate Nissan Ariya 2023
Diagnosis Procedure
Compressor does not operate.
CHECK MALFUNCTION SYMPTOM
Check if there are any symptoms that are not related to the air conditioning system.
Is the inspection result normal?
YES>>GO TO 2.
NO>>Perform applicable symptom diagnosis.
CHECK HIGH VOLTAGE JUNCTION BOX
Check high voltage junction box. Refer to Component Inspection.
Is the inspection result normal?
YES>>GO TO 3.
NO>>GO TO 5.
REPLACE A/C AUTO AMP.
Replace A/C auto amp. Refer to Removal & Installation.
Check the electric compressor operations in each mode.
Is the inspection result normal?
YES>>INSPECTION END
NO>>GO TO 4.
REPLACE HEAT PUMP CONTROL UNIT
Replace eat pump control unit. Refer to Removal & Installation.
Check the electric compressor operations in each mode.
Is the inspection result normal?
YES>>INSPECTION END
NO>>Replace electric compressor. Refer to Removal & Installation.
CHECK ELECTRIC COMPRESSOR
Check electric compressor. Refer to Component Inspection.
Is the inspection result normal?
YES>>Replace high voltage junction box. Refer to HIGH VOLTAGE JUNCTION BOX : Disassembly & Assembly.
NO>>Replace electric compressor (refer to Removal & Installation.), and then replace high voltage junction box. Refer to HIGH VOLTAGE JUNCTION BOX : Disassembly & Assembly.