Dtc Diagnosis

Shift (electric Shift Control Module)

In this manual: Dtc Diagnosis
How to Use This Manual — 1Precautions — 1Preparation — 1Vehicle Information — 1Basic Inspection — 1Preparation. Commercial Service Tools Or/and Repair Part — 1Description — 1Component Parts — 1System — 1Diagnosis System (vcm) — 1Ecu Diagnosis Information. Vcm — 1Ev Control System — 1Ev/hev (vcm) — 1Component Parts /circuit Diagnosis — 1Ev Control System — 1Periodic Maintenance. Ev System Warning Lamp — 1Removal and Installation. Vcm — 1Traction Motor System :: Front Traction Motor — 1Preparation — 1Description — 4Basic Inspection — 2Dtc Diagnosis — 2Component Parts /circuit Diagnosis — 1Traction Motor System :: Rear Traction Motor — 1Description — 4Basic Inspection — 2Dtc Diagnosis — 2Component Parts /circuit Diagnosis — 1Removal and Installation — 1Ev Battery System :: 66kwh Li-Ion Battery — 1Description — 4Basic Inspection — 2Dtc Diagnosis — 2Component Parts /circuit Diagnosis — 1Removal and Installation — 1Disassembly and Assembly — 2Service Data — 1Ev Battery System :: 91kwh Li-Ion Battery — 1Description — 4Basic Inspection — 2Dtc Diagnosis — 2Component Parts /circuit Diagnosis — 1Removal and Installation — 1Disassembly and Assembly — 1Service Data — 2Preparation. Vehicle Charging System — 1Vehicle Charging System :: Description — 1Component Parts — 2System — 1Diagnosis System (on-Board Charger) — 1Diagnosis System (dc/dc Converter) — 1Ecu Diagnosis Information — 1Vehicle Charging System — 1Charger/pd Module (on-Board Charger) — 1Cplc (cplc) — 1Dcdc (dc/dc Converter) — 1Component Parts/circuit Diagnosis — 1Symptom Diagnosis — 1Evse Inspection — 1Periodic Maintenance — 1Removal and Installation — 1Disassembly and Assembly — 1Preparation. High Voltage Cooling System — 1Description — 1Symptom Diagnosis. Overheating Cause Analysis — 1Periodic Maintenance — 1Coolant — 1Removal and Installation — 1Radiator — 1Service Data — 1Removal and Installation. Accelerator Control System — 1Reduction Gear: Re1f62a — 1Removal and Installation — 1Transaxle & Transmission :: Electric Shift — 1Description — 3Basic Inspection — 2Dtc Diagnosis — 2Component Parts /circuit Diagnosis — 1Removal and Installation — 1Rear Final Drive: Rn1r62a — 1Removal and Installation — 1Preparation. Front Axle System — 1Symptom Diagnosis. Noise, Vibration and Harshness (nvh) Troubleshooting — 1Periodic Maintenance — 1Removal and Installation — 1Service Data. Front Drive Shaft — 12wd — 14wd — 1Periodic Maintenance — 1Removal and Installation — 1Preparation. Front Suspension System — 1Symptom Diagnosis. Noise, Vibration and Harshness (nvh) Troubleshooting — 1Periodic Maintenance — 1Removal and Installation — 1Service Data — 1Symptom Diagnosis. Noise, Vibration and Harshness (nvh) Troubleshooting — 1Periodic Maintenance — 1Removal and Installation — 1Service Data — 1Preparation. Road Wheels & Tires System — 1Description — 1System — 1Ecu Diagnosis Information. Bcm (body Control Module) — 1Tpms — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Periodic Maintenance. Road Wheels & Tires — 1Removal and Installation — 1Service Data — 1Preparation. Brake System — 1System Description — 1Component Parts — 1Ecu Diagnosis Information. Electrically-Driven Intelligent Brake Unit — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Periodic Maintenance — 1Removal and Installation — 1Service Data — 1Preparation. Parking Brake System — 1System Description — 1Component Parts — 1System — 1Ecu Diagnosis Information. Abs Actuator and Electric Unit (control Unit) — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Component Parts /circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1Brake Control System :: With Vdc — 1System Description — 3Basic Inspection — 2Dtc/circuit Diagnosis — 1Symptom Diagnosis — 2Removal and Installation — 1Brake Control System :: Automatic Brake Hold — 1System Description — 3Component Parts /circuit Diagnosis — 1Removal and Installation — 1Brake Control System :: E-Step — 1System Description — 3Removal and Installation — 1System Description — 1Ecu Diagnosis Information — 1Basic Inspection — 1Symptom Diagnosis — 1Rear Automatic Braking — 1System Description — 1Basic Inspection — 1Preparation. Steering System — 1System Description — 1Component Parts — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Periodic Maintenance. Steering Wheel — 1Removal and Installation — 1Service Data — 1System Description — 1Component Parts — 1Steering Control System — 1Ecu Diagnosis Information. Power Steering Control Module — 1Dtc/circuit Diagnosis — 1Component Parts /circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation. Power Steering Control Module — 1System Description — 1Removal and Installation — 1System Description — 1System — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Component Parts — 1Basic Inspection — 1Removal and Installation — 1System Description — 1System — 1Ecu Diagnosis Information. Air Bag Diagnosis Sensor Unit — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1System Description. Description. Ventilation System — 1Removal and Installation — 1Preparation. Preparation — 1System Description — 1Basic Inspection — 1Symptom Diagnosis — 1Removal and Installation — 1Electric Compressor — 1Cooler Pipe and Hose — 1A/c Unit Assembly Cover — 1A/c Unit Assembly — 1Heater & Air Conditioning Control System :: Automatic Air Conditioning — 1System Description — 1Ecu Diagnosis Information — 1Basic Inspection — 2Dtc Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 2Preparation. Preparation — 1Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses — 1Removal and Installation — 1Preparation. Instrument Panel — 1Component Parts — 1System — 1Ecu Diagnosis Information. Flexible Center Storage Control Module — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1Preparation. Preparation — 1Component Parts — 1System — 1Ecu Diagnosis Information. Driver Lumbar Support Control Module — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1System Description — 1System — 1Ecu Diagnosis Information — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Manual Function Does Not Operate — 1Memory Function Does Not Operate — 1Removal and Installation — 1Preparation. Preparation — 1System Description — 1System (intelligent Key System) — 1Diagnosis System (bcm) — 1Ecu Diagnosis Information — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1U2141-87 Can Comm Circuit — 1Power Supply and Ground Circuit — 1Symptom Diagnosis — 1Automatic Back Door Operation Does Not Operate — 1Back Door Does Not Open — 1Door Does Not Lock/unlock with Door Lock and Unlock Switch — 1Removal and Installation — 1Hood — 1Radiator Core Support — 1Charge Port Lid — 1Front Fender — 1Front Door — 1Rear Door — 1Back Door — 1Hood Lock — 1Front Door Lock — 1Rear Door Lock — 1Back Door Lock — 1Outside Key Antenna — 1System Description — 1System — 1Ecu Diagnosis Information. Inverter (front), Inverter (rear), Bcm, Intelligent Key Unit — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Preparation — 1Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses — 1Removal and Installation — 1System Description — 1Ecu Diagnosis Information — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Power Supply and Ground Circuit — 1Symptom Diagnosis — 1Front Passenger Side Power Window Does Not Operate — 1Rear Lh Side Power Window Does Not Operate — 1Rear Rh Side Power Window Does Not Operate — 1Removal and Installation. Power Window Main Switch — 1Preparation. Preparation — 1System Description — 1Ecu Diagnosis Information — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Power Supply and Ground Circuit — 1Sunroof Switch Assembly — 1Symptom Diagnosis — 1Auto Operation Does Not Operate — 1Removal and Installation — 1Preparation — 1Description — 1Symptom Diagnosis. Squeak and Rattle Trouble Diagnoses — 1Removal and Installation — 1Service Information — 6Repair Information — 1Precaution — 1Preparation — 1Removal and Installation — 1Service Data — 1Preparation. Preparation — 1Component Parts — 1System — 1Ecu Diagnosis Information — 1Wiring Diagram. Door Mirror — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Power Supply and Ground Circuit — 1Symptom Diagnosis — 1Removal and Installation — 1Exterior Lighting System :: Led Headlamp — 1System Description — 3Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Periodic Maintenance — 1Removal and Installation — 1System Description — 1System — 1Diagnosis System (bcm) — 1Ecu Diagnosis Information. Bcm, Intelligent Key Unit — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis. Interior Lighting System Symptom — 1Removal and Installation — 1Service Data. Bulb Specifications — 1System Description — 1System — 1Ecu Diagnosis Information. Bcm, Ipdm E/r — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1System Description — 1Ecu Diagnosis Information. Bcm — 1Basic Inspection. Diagnosis and Repair Work Flow — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1Preparation. Preparation — 1Removal and Installation. Horn — 1Preparation. Commercial Service Tools Or/and Repair Part — 1System Description — 1Component Parts — 1Ecu Diagnosis Information. Approaching Vehicle Sound for Pedestrians (vsp) Control Unit — 1Approaching Vehicle Sound for Pedestrians (vsp) — 1Vsp [approaching Vehicle Sound for Pedestrians (vsp) Control Unit] — 1Approaching Vehicle Sound for Pedestrians (vsp) System — 1Removal and Installation — 1Removal and Installation — 1Wireless Charger — 1System Description — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Removal and Installation — 1Component Parts — 1System — 1Diagnosis System (bcm) — 1Ecu Diagnosis Information. Bcm — 1Basic Inspection — 1Dtc/circuit Diagnosis — 1Symptom Diagnosis — 1Removal and Installation — 1Can Fundamental — 1Description — 1Trouble Diagnosis — 1Can (controller Area Network) — 1Description — 1
208steps
~1248min
5/5difficulty
Done 0 of 208
  • P0604-00 Control Module Ram
  • P0681-00 Sensor Power Supply
  • P072a-00 Stuck in Neutral
  • P07e9-00 T/m Range Control
  • P07ec-00 T/m Range Multifunction Select
  • P0850-00 Park/neutral Switch
  • P0851-00 Park/neutral Switch
  • P1897-00 Encoder Error
  • P189d-00 Back up Voltage
  • P18a8-00 P Position Switch
  • P18ac-00 Motor Relay
  • P18b4-00 Park Status
  • P272a-00 Motor Driver Circuit
  • P272b-00 Motor Driver Circuit
  • U18a1-86 Can Comm Circuit
  • U18a2-86 Can Comm Circuit
  • U215b-87 Can Comm Circuit

P0604-00 Control Module Ram Nissan Ariya

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P0604 00 Control Module RAM Diagnosis condition Power switch ON
Signal (terminal) —
Threshold When an error is detected in the electric shift control module.
Diagnosis delay time —

POSSIBLE CAUSE

Electric shift control module internal error (RAM error)

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Power switch from OFF to ON and wait 2 seconds or more.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "P0604-00" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

REPLACEMENT OF THE ELECTRIC SHIFT CONTROL MODULE

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

>>

END

P0681-00 Sensor Power Supply Nissan Ariya first Gen

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P0681 00 Sensor Power Supply A 1 Diagnosis condition READY
Signal (terminal) Electric shift sensor input signal
Threshold It was detected that electric shift sensor No.1, 3, 5, and 7 are stuck OFF, and this state was detected 5 times or more.
Diagnosis delay time —
2 Diagnosis condition READY
Signal (terminal) Electric shift sensor input signal
Threshold It was detected that electric shift sensor No.2, 4, 6, and 8 are stuck OFF, and this state was detected 5 times or more.
Diagnosis delay time —
POSITION PATTERN
Selector lever positionElectric shift sensor
No. 1No. 2No. 3No. 4No. 5No. 6No. 7No. 8
R ON ON OFF OFF OFF OFF OFF OFF
Nr ON ON ON ON ON OFF OFF OFF
H ON ON ON ON ON ON ON ON
Nd OFF OFF OFF ON ON ON ON ON
D/B OFF OFF OFF OFF OFF OFF ON ON

POSSIBLE CAUSE

  • Electric shift sensor

  • Electric shift control module

  • Harness or connectors

    (Open or short-circuit of the harness of each circuit)

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

ERASE SELF-DIAGNOSIS RESULT

With CONSULT

Erase self-diagnostic result for “SHIFT”.

>>

GO TO 3.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select "Actual shift position".

  4. Operate the selector lever as follows. (Keep the selector lever at each shift position for at least 2 seconds.)

    • H → N → R → N → D → N → H

  5. Repeat step 4 an additional 5 times.

  6. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "P0681–00" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

ELECTRIC SHIFT SENSOR INPUT SIGNAL INSPECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select “Shift sensor 1” to “Shift sensor 8”.

  4. Operate the selector lever and confirm the shift sensor in which the value is not switched.

    Monitor itemConditionValue/Status
    Shift sensor 1 Selector lever: H (home position) and kept in the R and Nr position On
    Other than the above Off
    Shift sensor 2 Selector lever: H (home position) and kept in the R and Nr position On
    Other than the above Off
    Shift sensor 3 Selector lever: H (home position) and kept in the Nr position On
    Other than the above Off
    Shift sensor 4 Selector lever: H (home position) and kept in the Nr and Nd position On
    Other than the above Off
    Shift sensor 5 Selector lever: H (home position) and kept in the Nr and Nd position On
    Other than the above Off
    Shift sensor 6 Selector lever: H (home position) and kept in the Nd position On
    Other than the above Off
    Shift sensor 7 Selector lever: H (home position) and kept in the Nd and D position On
    Other than the above Off
    Shift sensor 8 Selector lever: H (home position) and kept in the Nd and D position On
    Other than the above Off

Without CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Operate the selector lever and check the voltage between electric shift control module harness connector and ground.

    Electric shift sensor+-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    No.1 M203 34 Ground Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.2 35 Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.3 36 Selector lever: H (home position) and kept in the Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.4 37 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.5 44 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.6 45 Selector lever: H (home position) and kept in the Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.7 39 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.8 40 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
>>

GO TO 2.

ELECTRIC SHIFT SENSOR POWER SUPPLY INSPECTION

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Power switch ON.

  4. Check the power source circuit of the troubled shift sensor confirmed in the step 1.

  5. Check the voltage between electric shift selector harness connector and ground.

    Electric shift sensor+-Voltage
    Electric shift selector
    ConnectorTerminal

    No.1

    No.3

    No.5

    No.7
    M200 1 Ground Approx. 5 V

    No.2

    No.4

    No.6

    No.8
    13

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

GO TO 3.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND ELECTRIC SHIFT SENSOR (SENSOR POWER CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift sensorElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal

    No.1

    No.3

    No.5

    No.7
    M202 19 M200 1 Existed

    No.2

    No.4

    No.6

    No.8
    M203 48 13
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift sensorElectric shift control module―Continuity
    ConnectorTerminal

    No.1

    No.3

    No.5

    No.7
    M202 19 Ground Not existed

    No.2

    No.4

    No.6

    No.8
    M203 48

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

CHECK ELECTRIC SHIFT SENSOR GROUND CIRCUIT

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift sensorElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal

    No.1

    No.3

    No.5

    No.7
    M203 41 M200 12 Existed

    No.2

    No.4

    No.6

    No.8
    50 24
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift sensorElectric shift control module―Continuity
    ConnectorTerminal

    No.1

    No.3

    No.5

    No.7
    M203 41 Ground Not existed

    No.2

    No.4

    No.6

    No.8
    50

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND ELECTRIC SHIFT SENSOR (SENSOR SIGNAL CIRCUIT)

  1. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift sensorElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    No.1 M203 34 M200 2 Existed
    No.2 35 14
    No.3 36 3
    No.4 37 15
    No.5 44 4
    No.6 45 16
    No.7 39 5
    No.8 40 17
  2. Check the continuity between electric shift control module harness connector and ground.

    Electric shift sensorElectric shift control module―Continuity
    ConnectorTerminal
    No.1 M203 34 Ground Not existed
    No.2 35
    No.3 36
    No.4 37
    No.5 44
    No.6 45
    No.7 39
    No.8 40

Is the inspection result normal?

YES>>

Due to the malfunction of the electric shift sensor, replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

P072a-00 Stuck in Neutral Nissan Ariya 1st generation

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P072A 00 Stuck In Neutral Diagnosis condition READY
Signal (terminal) —
Threshold After activation of the parking actuator stops, it was detected that the parking actuator is in the neutral position of the manual plate and does not move.
Diagnosis delay time 5 seconds or more

POSSIBLE CAUSE

Parking actuator (Parking mechanism)

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select "Actual shift position".

  4. Operate the selector lever 5 times as follows.

    • P → N → P

  5. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "P072A-00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO>>

INSPECTION END

DTC Diagnosis Procedure

REPLACEMENT OF REDUCTION GEAR

Replace reduction gear due to the malfunction of parking actuator. Refer to REDUCTION GEAR : Unit Removal & Installation.

>>

END

P07e9-00 T/m Range Control Nissan Ariya

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P07E9 00 Transmission Range Control Diagnosis condition READY
Signal (terminal) Electric shift sensor input signal
Threshold

The input voltage is one of the following in one of electric shift sensors No.1 to No.8.

  • 0.6 V < Input voltage < 1.1 V

  • 2.1 V < Input voltage < 2.7 V

  • 3.2 V < Input voltage < 4.5 V

Diagnosis delay time 2.4 seconds or more

POSSIBLE CAUSE

  • Electric shift selector (Electric shift sensor)

  • Electric shift control module

  • Harness or connectors (Electric shift sensor circuit is open or shorted.)

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select "Actual shift position".

  4. Operate the selector lever as follows. (Keep the selector lever at each shift position for at least 3 seconds.)

    • H → N → R → N → D → N → H

  5. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "P07E9-00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK ELECTRIC SHIFT SENSOR INPUT VOLTAGE

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select “Shift sensor 1 voltage” to “Shift sensor 8 voltage”.

  4. Operate the selector lever and check the input voltage to the electric shift control module.

    Monitor itemConditionValue/Status
    Shift sensor 1 voltage Selector lever: H (home position) and kept in the R and Nr position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 2 voltage Selector lever: H (home position) and kept in the R and Nr position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 3 voltage Selector lever: H (home position) and kept in the Nr position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 4 voltage Selector lever: H (home position) and kept in the Nr and Nd position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 5 voltage Selector lever: H (home position) and kept in the Nr and Nd position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 6 voltage Selector lever: H (home position) and kept in the Nd position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 7 voltage Selector lever: H (home position) and kept in the Nd and D position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V
    Shift sensor 8 voltage Selector lever: H (home position) and kept in the Nd and D position 1.1 - 2.1 V
    Other than the above 2.7 - 3.2 V

Without CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Operate the selector lever and check the voltage between electric shift control module harness connector and ground.

    Electric shift sensor+-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    No.1 M203 34 Ground Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.2 35 Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.3 36 Selector lever: H (home position) and kept in the Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.4 37 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.5 44 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.6 45 Selector lever: H (home position) and kept in the Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.7 39 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.8 40 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

GO TO 2.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND ELECTRIC SHIFT SENSOR (SENSOR SIGNAL CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Disconnect electric shift control module harness connector.

  4. Check the resistance between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift sensorElectric shift control moduleElectric shift selectorResistance
    ConnectorTerminalConnectorTerminal
    No.1 M203 34 M200 2 1 Ω or less
    No.2 35 14
    No.3 36 3
    No.4 37 15
    No.5 44 4
    No.6 45 16
    No.7 39 5
    No.8 40 17

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace the error-detected parts.

REPLACE ELECTRIC SHIFT SELECTOR

  1. Replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

  2. Connect all of disconnected connectors.

  3. Perform DTC “Confirmation Procedure”. Refer to Confirmation Procedure.

Is "P07E9-00" detected again?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

INSPECTION END

P07ec-00 T/m Range Multifunction Select Nissan Ariya 1st generation

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P07EC 00 Transmission Range Multi-function Select Diagnosis condition READY
Signal (terminal) Electric shift sensor input signal
Threshold Any of electric shift sensors No.1 to No.8 was detected stuck ON or OFF 5 times or more.
Diagnosis delay time ―
POSITION PATTERN
Selector lever positionElectric shift sensor
No. 1No. 2No. 3No. 4No. 5No. 6No. 7No. 8
R ON ON OFF OFF OFF OFF OFF OFF
Nr ON ON ON ON ON OFF OFF OFF
H ON ON ON ON ON ON ON ON
Nd OFF OFF OFF ON ON ON ON ON
D/B OFF OFF OFF OFF OFF OFF ON ON

POSSIBLE CAUSE

  • Electric shift sensor

  • Harness or connectors

    (Open or short-circuit of the harness of each circuit)

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

ERASE SELF-DIAGNOSIS RESULT

With CONSULT

Erase self-diagnostic result for “SHIFT”.

>>

GO TO 3

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select "Actual shift position".

  4. Operate the selector lever as follows. (Keep the selector lever at each shift position for at least 2 seconds.)

    • H → N → R → N → D → N → H

  5. Repeat step 4 an additional 5 times.

  6. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P07EC–00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

ELECTRIC SHIFT SENSOR INPUT SIGNAL INSPECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select “Shift sensor 1” to “Shift sensor 8”.

  4. Operate the selector lever and confirm the shift sensor in which the value is not switched.

    Monitor itemConditionValue/Status
    Shift sensor 1 Selector lever: H (home position) and kept in the R and Nr position On
    Other than the above Off
    Shift sensor 2 Selector lever: H (home position) and kept in the R and Nr position On
    Other than the above Off
    Shift sensor 3 Selector lever: H (home position) and kept in the Nr position On
    Other than the above Off
    Shift sensor 4 Selector lever: H (home position) and kept in the Nr and Nd position On
    Other than the above Off
    Shift sensor 5 Selector lever: H (home position) and kept in the Nr and Nd position On
    Other than the above Off
    Shift sensor 6 Selector lever: H (home position) and kept in the Nd position On
    Other than the above Off
    Shift sensor 7 Selector lever: H (home position) and kept in the Nd and D position On
    Other than the above Off
    Shift sensor 8 Selector lever: H (home position) and kept in the Nd and D position On
    Other than the above Off

Without CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Operate the selector lever and check the voltage between electric shift control module harness connector and ground.

    Electric shift sensor+-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    No.1 M203 34 Ground Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.2 35 Selector lever: H (home position) and kept in the R and Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.3 36 Selector lever: H (home position) and kept in the Nr position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.4 37 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.5 44 Selector lever: H (home position) and kept in the Nr and Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.6 45 Selector lever: H (home position) and kept in the Nd position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.7 39 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
    No.8 40 Selector lever: H (home position) and kept in the Nd and D position 1.4 - 2.0 V
    Other than the above 2.8 - 3.2 V
>>

GO TO 2.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND ELECTRIC SHIFT SENSOR

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector and electric shift selector harness connector.

  3. Check the continuity between electric shift control module harness connector and electric shift selector harness connector of the troubled shift sensor confirmed in the step 1.

    Electric shift sensorElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    No.1 M203 34 M200 2 Existed
    No.2 35 14
    No.3 36 3
    No.4 37 15
    No.5 44 4
    No.6 45 16
    No.7 39 5
    No.8 40 17
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift sensorElectric shift control module―Continuity
    ConnectorTerminal
    No.1 M203 34 Ground Not existed
    No.2 35
    No.3 36
    No.4 37
    No.5 44
    No.6 45
    No.7 39
    No.8 40
  5. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift sensorElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    No.1 M203 34 M200 1, 13 Not existed
    No.2 35
    No.3 36
    No.4 37
    No.5 44
    No.6 45
    No.7 39
    No.8 40

Is the inspection result normal?

YES>>

Due to the malfunction of the electric shift sensor, replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

P0850-00 Park/neutral Switch Nissan Ariya: FE0

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P0850 00 Park/Neutral Switch Diagnosis condition READY
Signal (terminal) P position switch input signal
Threshold

The input voltage is one of the following in one of P position switches No.1 and No.2.

  • 0.6 V < Input voltage < 1.1 V

  • 2.1 V < Input voltage < 2.7 V

  • 3.2 V < Input voltage < 4.5 V

Diagnosis delay time 2.4 seconds or more

POSSIBLE CAUSE

  • Electric shift selector (P position switch)

  • Electric shift control module

  • Harness or connectors (P position switch circuit is open or shorted.)

FAIL-SAFE

Does not shift to P position even when the P position switch is pressed.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Press the P position switch to shift to the P position and wait for at least 5 seconds. (Press the P position for at least 1 second.)

  3. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P0850–00” detect?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK P POSITION SWITCH INPUT VOLTAGE

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select “P position switch 1 voltage” and “P position switch 2 voltage”.

  4. Operate the P position switch and measure the input voltage to the electric shift control module.

    Monitor itemConditionValue/Status
    P position switch 1 voltage P position switch: Pressed 1.1 - 2.1 V
    P position switch: Released 2.7 - 3.2 V
    P position switch 2 voltage P position switch: Pressed 2.7 - 3.2 V
    P position switch: Released 1.1 - 2.1 V

Without CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Operate the P position switch and check the voltage between electric shift control module harness connector and ground.

    P position switch+-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    No.1 M203 46 Ground P position switch: Pressed 1.4 - 2.0 V
    P position switch: Released 2.8 - 3.2 V
    No.2 47 P position switch: Pressed 2.8 - 3.2 V
    P position switch: Released 1.4 - 2.0 V

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

GO TO 2.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND P POSITION SWITCH (SENSOR SIGNAL CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Disconnect electric shift control module harness connector.

  4. Check the resistance between electric shift control module harness connector and electric shift selector harness connector.

    P position switchElectric shift control moduleElectric shift selectorResistance
    ConnectorTerminalConnectorTerminal
    No.1 M203 46 M200 6 1 Ω or less
    No.2 47 18

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace the error-detected parts.

REPLACE ELECTRIC SHIFT SELECTOR

  1. Replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

  2. Connect all of disconnected connectors.

  3. Perform DTC “Confirmation Procedure”. Refer to Confirmation Procedure.

Is "P0850-00" detected again?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

INSPECTION END

P0851-00 Park/neutral Switch Nissan Ariya 2026

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P0851 00 Park/Neutral Switch Diagnosis condition READY
Signal (terminal) P position switch input signal
Threshold

The input voltage of P position switch No.1 and No.2 was continuously the following state.

  • Input voltage ≦ 0.6 V

Diagnosis delay time 2.4 seconds or more

POSSIBLE CAUSE

  • Electric shift selector (P position switch)

  • Electric shift control module

  • Harness or connectors (P position switch circuit is shorted to ground.)

FAIL-SAFE

Does not shift to P position even when the P position switch is pressed.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Press the P position switch to shift to the P position and wait for at least 5 seconds. (Press the P position for at least 1 second.)

  3. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P0851–00” detect?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK P POSITION SWITCH INPUT VOLTAGE

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Select “Data Monitor” in “SHIFT”.

  3. Select “P position switch 1 voltage” and “P position switch 2 voltage”.

  4. Operate the P position switch and measure the input voltage to the electric shift control module.

    Monitor itemConditionValue/Status
    P position switch 1 voltage P position switch: Pressed 1.1 - 2.1 V
    P position switch: Released 2.7 - 3.2 V
    P position switch 2 voltage P position switch: Pressed 2.7 - 3.2 V
    P position switch: Released 1.1 - 2.1 V

Without CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Operate the P position switch and check the voltage between electric shift control module harness connector and ground.

    P position switch+-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    No.1 M203 46 Ground P position switch: Pressed 1.4 - 2.0 V
    P position switch: Released 2.8 - 3.2 V
    No.2 47 P position switch: Pressed 2.8 - 3.2 V
    P position switch: Released 1.4 - 2.0 V

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

GO TO 2.

P POSITION SWITCH POWER SUPPLY INSPECTION

  1. Power switch ON.

  2. Check the voltage between electric shift selector harness connector and ground.

    +-Voltage
    Electric shift selector
    ConnectorTerminal
    M200 1 Ground Approx. 5 V
    13

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

GO TO 3.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND P POSITION SWITCH (SENSOR POWER CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Disconnect electric shift control module harness connector.

  4. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    M202 19 M200 1 Existed
    M203 48 13
  5. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 19 Ground Not existed
    M203 48

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

CHECK P POSITION SWITCH SENSOR GROUND CIRCUIT

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Disconnect electric shift control module harness connector.

  4. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    M203 41 M200 12 Existed
    50 24
  5. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M203 41 Ground Not existed
    50

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND P POSITION SWITCH (SWITCH SIGNAL CIRCUIT)

  1. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    P position switchElectric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    No.1 M203 46 M200 6 Existed
    No.2 47 18
  2. Check the continuity between electric shift control module harness connector and ground.

    P position switchElectric shift control module―Continuity
    ConnectorTerminal
    No.1 M203 46 Ground Not existed
    No.2 47
  3. Check the continuity between electric shift control module harness connector terminals.

    P position switchElectric shift control moduleContinuity
    ConnectorTerminalConnectorTerminal
    No.1 M203 46 M203 Except 46 Not existed
    No.2 47 Except 47

Is the inspection result normal?

YES>>

Due to the malfunction of the P position switch, replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

P1897-00 Encoder Error Nissan Ariya 2026

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P1897 00 Encoder Diagnosis condition When parking actuator is driven.
Signal (terminal) Parking actuator control signal
Threshold Even when the electric shift control module drives the parking actuator, the encoder signal is not outputted.
Diagnosis delay time —

POSSIBLE CAUSE

  • Encoder

    (Parking actuator)

  • Electric shift control module

  • Harness or connectors

    (Open or short-circuit of the harness of each circuit)

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Shift the selector lever to the N position and wait for at least 10 seconds.

  3. Press the P position switch to shift to the P position and wait for at least 10 seconds.

  4. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P1897-00” detect?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

ENCODER POWER SUPPLY INSPECTION

  1. Power switch OFF.

  2. Disconnect the parking actuator harness connector.

  3. Power switch ON.

  4. Check the voltage between parking actuator harness connector and ground.

    +-Voltage
    Parking actuator
    ConnectorTerminal
    F15 9 Ground Approx. 5 V

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

GO TO 3.

CHECK THE CIRCUIT BETWEEN THE ELECTRIC SHIFT CONTROL MODULE AND ENCODER (SIGNAL)

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the continuity between electric shift control module harness connector and parking actuator harness connector.

    Electric shift control moduleParking actuatorContinuity
    ConnectorTerminalConnectorTerminal
    M202 15 F15 5 Existed
    23 8
    24 3
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 15 Ground Not existed
    23
    24

Is the inspection result normal?

YES>>

Replace reduction gear due to the malfunction of encoder (in parking actuator). Refer to REDUCTION GEAR : Unit Removal & Installation.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN THE ELECTRIC SHIFT CONTROL MODULE AND ENCODER (POWER)

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the continuity between electric shift control module harness connector and parking actuator harness connector.

    Electric shift control moduleParking actuatorContinuity
    ConnectorTerminalConnectorTerminal
    M202 16 F15 9 Existed
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 16 Ground Not existed

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

P189d-00 Back up Voltage Nissan Ariya 1st generation

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P189D 00 Power-supply Voltage Diagnosis condition Power switch ON
Signal (terminal) Battery power supply signal (auto ACC) (2 lines)
Threshold

The following battery power supply (auto ACC) voltage was detected.

  • Battery power supply (auto ACC) voltage < 9 V

Diagnosis delay time 2 seconds or more

POSSIBLE CAUSE

  • Electric shift control module

  • Harness, fuse, or connector

    (Open or short-circuit of each circuit)

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 5 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P189D-00" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK BATTERY POWER SUPPLY CIRCUIT

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the voltage between electric shift control module harness connector and ground.

    +-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    M202 8 Ground Power switch: ON or ACC 9 – 16 V
    Power switch: OFF Approx. 0 V
    M203 42 Power switch: ON or ACC 9 – 16 V
    Power switch: OFF Approx. 0 V

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

GO TO 3.

CHECK ELECTRIC SHIFT CONTROL MODULE GROUND CIRCUIT

  1. Power switch OFF.

  2. Check continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 3 Ground Existed
    4
    6
    M203 25

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

DETECT MALFUNCTIONING ITEMS

Check the following items:

  • Harness for short or open between electric shift control module harness connector terminal 8 and fuse block (J/B) harness connector terminal 95

  • Harness for short or open between electric shift control module harness connector terminal 42 and fuse block (J/B) harness connector terminal 132

  • 12V battery (Refer to Work Flow.)

  • 10A fuse (#49)

  • 10A fuse (#52)

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Repair or replace the error-detected parts.

P18a8-00 P Position Switch Nissan Ariya SUV

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P18A8 00 P Position Switch 1 Diagnosis condition READY
Signal (terminal) P position switch input signal
Threshold P position switch No.1 and No.2 are stuck ON or OFF.
Diagnosis delay time —
2 Diagnosis condition READY
Signal (terminal) P position switch No.1, No.2 signal
Threshold P position switch No.1 is stuck ON and No.2 is stuck OFF.
Diagnosis delay time 5 minutes or more
P POSITION SWITCH PATTERN
P position switch operating conditionP position switch
No.1No.2
Not pressed OFF ON
Pressed ON OFF

POSSIBLE CAUSE

  • P position switch

  • Electric shift control module

  • Wiring harness

    (Open or short-circuit of the harness of each circuit)

FAIL-SAFE

Does not shift to P position even when the P position switch is pressed.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the Nissan Ariya vehicle to READY.

  2. Press the P position switch to shift to the P position and wait for at least 5 seconds. (Press the P position for at least 1 second.)

  3. Shift the selector lever to the N position and wait for at least 5 minutes.

  4. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P18A8–00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

P POSITION SWITCH POWER SUPPLY INSPECTION

  1. Power switch OFF.

  2. Disconnect electric shift selector harness connector.

  3. Power switch ON.

  4. Check the voltage between electric shift selector harness connector and ground.

    +-Voltage
    Electric shift selector
    ConnectorTerminal
    M200 1 Ground Approx. 5 V
    13

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

GO TO 2.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND P POSITION SWITCH (SENSOR POWER CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    M202 19 M200 1 Existed
    M203 48 13
  4. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 19 Ground Not existed
    M203 48

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND P POSITION SWITCH (SWITCH SIGNAL CIRCUIT)

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Disconnect electric shift selector harness connector.

  4. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    M203 46 M200 6 Existed
    47 18
  5. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M203 46 Ground Not existed
    47

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Repair or replace the error-detected parts.

CHECK P POSITION SWITCH SENSOR GROUND CIRCUIT

  1. Check the continuity between electric shift control module harness connector and electric shift selector harness connector.

    Electric shift control moduleElectric shift selectorContinuity
    ConnectorTerminalConnectorTerminal
    M203 41 M200 12 Existed
    50 24
  2. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M203 41 Ground Not existed
    50

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

Repair or replace the error-detected parts.

P POSITION SWITCH INSPECTION

  1. Connect all of disconnected connectors.

  2. Power switch ON.

  3. Check the voltage between electric shift selector harness connector and ground.

    +-ConditionVoltage
    Electric shift selector
    ConnectorTerminal
    M200 6 Ground P position switch: Pressed 1.4 - 2.0 V
    P position switch: Released 2.8 - 3.2 V
    18 P position switch: Pressed 2.8 - 3.2 V
    P position switch: Released 1.4 - 2.0 V

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Due to the malfunction of the P position switch, replace the electric shift selector. Refer to ELECTRIC SHIFT SELECTOR : Removal & Installation.

P18ac-00 Motor Relay Nissan Ariya 2026

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P18AC 00 Parking Actuator Relay Diagnosis condition Power switch ON
Signal (terminal) Motor coil (U-phase, V-phase, W-phase) signal
Threshold In spite of the OFF instruction state of parking actuator relay, voltage was detected from all phases of motor coil (U-phase, V-phase, and W-phase).
Diagnosis delay time —

POSSIBLE CAUSE

  • Parking actuator relay (ON stuck)

  • Electric shift control module

  • Wiring harness (short-circuit)

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 2 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P18AC-00" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND PARKING ACTUATOR RELAY

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Remove the parking actuator relay.

  4. Check the continuity between parking actuator relay harness connector and ground.

    Parking actuator relay―Continuity
    ConnectorTerminal
    E105 2 Ground Not existed

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN PARKING ACTUATOR AND PARKING ACTUATOR RELAY

  1. Disconnect the parking actuator harness connector.

  2. Check the voltage between parking actuator harness connector and ground.

    +-Voltage
    Parking actuator
    ConnectorTerminal
    F15 2 Ground Approx. 0 V

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN THE ELECTRIC SHIFT CONTROL MODULE AND PARKING ACTUATOR

Check the voltage between electric shift control module harness connector and ground.

+-Voltage
Electric shift control module
ConnectorTerminal
M203 27 Ground Approx. 0 V
28
29

Is the inspection result normal?

YES>>

GO TO 4.

NO>>

Repair or replace the error-detected parts.

PARKING ACTUATOR RELAY INSPECTION

Check parking actuator relay. Refer to Component Inspection.

Is the inspection result normal?

YES>>

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Replace parking actuator relay.

P18b4-00 Park Status Nissan Ariya

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P18B4 00 Park Status Diagnosis condition Power switch ON
Signal (terminal) Current position signal
Threshold There is an error in the calculation results of the electric shift control module and an error value was detected in circuit board component.
Diagnosis delay time 3 seconds or more

POSSIBLE CAUSE

  • Actuator position learning incomplete

  • Electric shift control module

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 3 seconds.

  2. Set the Nissan Ariya vehicle to READY.

  3. Press the P position switch to shift to the P position and wait for at least 5 seconds. (Press the P position for at least 1 second.)

  4. Operate the selector lever as follows. (Keep the selector lever at each shift position for at least 3 seconds.)

    • H → N → R → N → D → N → H

  5. Set the power switch to OFF and wait at least 60 seconds.

  6. Set the power switch to ON again.

  7. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P18B4-00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

REPLACEMENT OF THE ELECTRIC SHIFT CONTROL MODULE

Replace electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

>>

END

P272a-00 Motor Driver Circuit Nissan Ariya first Gen

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P272A 00 Motor Driver Circuit Diagnosis condition Power switch ON
Signal (terminal) Parking actuator control signal (U-phase, V-phase, W-phase)
Threshold

Although all phases (U-phase, V-phase, W-phase) of the parking actuator control signal are de-energized, 1 of the phases is energized.

De-energized: 9 - 16 V

Diagnosis delay time —

POSSIBLE CAUSE

  • Parking actuator relay (OFF stuck)

  • Motor coil

    (Parking actuator)

  • Electric shift control module

  • Harness or connectors

    (Open of each circuit or ground short-circuit)

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 2 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P272A-00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK THE CIRCUIT BETWEEN THE ELECTRIC SHIFT CONTROL MODULE AND MOTOR COIL

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Disconnect the parking actuator harness connector.

  4. Check the continuity between electric shift control module harness connector and parking actuator harness connector.

    Electric shift control moduleParking actuatorContinuity
    ConnectorTerminalConnectorTerminal
    M203 27 F15 1 Existed
    28 6
    29 7
  5. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M203 27 Ground Not existed
    28
    29

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace the error-detected parts.

PARKING ACTUATOR RELAY INSPECTION

  1. Power switch OFF.

  2. Remove the parking actuator relay.

  3. Check parking actuator relay. Refer to Component Inspection.

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Replace parking actuator relay.

CHECK THE CIRCUIT BETWEEN THE PARKING ACTUATOR RELAY AND 12V BATTERY

Check the voltage between parking actuator relay harness connector and ground.

+-Voltage
Parking actuator relay
ConnectorTerminal
E105 1 Ground 9 – 16 V
5

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

GO TO 4.

DETECT MALFUNCTIONING ITEM

Check the following items:

  • Harness for short or open between parking actuator relay and 12V battery.

  • 12V battery

  • 30A fuse (#100)

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN PARKING ACTUATOR AND PARKING ACTUATOR RELAY

Check the continuity between parking actuator harness connector and parking actuator relay harness connector.

Parking actuatorParking actuator relayContinuity
ConnectorTerminalConnectorTerminal
F15 2 E105 3 Existed

Is the inspection result normal?

YES>>

GO TO 6.

NO>>

Repair or replace the error-detected parts.

CHECK THE CIRCUIT BETWEEN ELECTRIC SHIFT CONTROL MODULE AND PARKING ACTUATOR RELAY

  1. Check the continuity between electric shift control module harness connector and parking actuator relay harness connector.

    Electric shift control moduleParking actuator relayContinuity
    ConnectorTerminalConnectorTerminal
    M203 33 E105 2 Existed
  2. Check the continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M203 33 Ground Not existed

Is the inspection result normal?

YES>>

GO TO 7.

NO>>

Repair or replace the error-detected parts.

MOTOR COIL (IN PARKING ACTUATOR) INSPECTION

Check motor coil (in parking actuator). Refer to Component Inspection.

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Replace reduction gear due to the malfunction of motor coil (in parking actuator). Refer to REDUCTION GEAR : Unit Removal & Installation.

P272b-00 Motor Driver Circuit Nissan Ariya 1st generation

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
P272B 00 Motor Driver Circuit Diagnosis condition Parking actuator is driven when power switch ON.
Signal (terminal) Parking actuator control signal (U-phase, V-phase, W-phase)
Threshold

Of 2 phases (U-phase, V-phase, W-phase) of the parking actuator control signal, 1 of the phases is de-energized.

De-energized: 9 - 16 V

Diagnosis delay time —

POSSIBLE CAUSE

  • Electric shift control module

  • Motor coil

    (Parking actuator)

  • Wiring harness

    (12V battery short-circuit)

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 2 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is “P272B-00” detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK THE CIRCUIT BETWEEN THE ELECTRIC SHIFT CONTROL MODULE AND MOTOR COIL

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Disconnect the parking actuator harness connector.

  4. Check the voltage between electric shift control module harness connector and ground.

    +-Voltage
    Electric shift control module
    ConnectorTerminal
    M203 27 Ground Approx. 0 V
    28
    29
  5. Check the continuity between electric shift control module harness connector and parking actuator harness connector.

    Electric shift control moduleParking actuatorContinuity
    ConnectorTerminalConnectorTerminal
    M203 27 F15 1 Existed
    28 6
    29 7

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace the error-detected parts.

MOTOR COIL (IN PARKING ACTUATOR) INSPECTION

Check motor coil (in parking actuator). Refer to Component Inspection.

Is the inspection result normal?

YES>>

INSPECTION END

NO>>

Replace reduction gear due to the malfunction of motor coil (in parking actuator). Refer to REDUCTION GEAR : Unit Removal & Installation.

U18a1-86 Can Comm Circuit Nissan Ariya 1st generation

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
U18A1 86 CAN Communication Error (BCM) Diagnosis condition Power switch ON
Signal (terminal) CAN communication
Threshold Invalid CAN communication signal from BCM was received.
Diagnosis delay time 2 seconds or more

POSSIBLE CAUSE

  • Harness or connectors

    (Open or short-circuit of the CAN communication line)

  • CAN bus of electric shift control module

  • BCM

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 5 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "U18A1-86" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

For the trouble diagnosis procedure, Refer to Trouble Diagnosis Flow Chart.

U18a2-86 Can Comm Circuit Nissan Ariya first Gen

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
U18A2 86 CAN Communication Error (VCM) Diagnosis condition Power switch ON
Signal (terminal) CAN communication
Threshold Invalid CAN communication signal from VCM was received.
Diagnosis delay time ―

POSSIBLE CAUSE

  • Harness or connectors

    (Open or short-circuit of the CAN communication line)

  • CAN bus of electric shift control module

  • VCM

  • 12V battery

  • Open of the power ON signal circuit of electric shift control module

FAIL-SAFE

  • In case of malfunction in the P position: Shifting from the P position to any other position is prohibited.

  • In case of malfunction in a position other than the P position: Shifting to the P position is prohibited.

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 5 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "U18A2-86" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK 12V BATTERY

Check 12V battery. Refer to Work Flow.

Is the inspection result normal?

YES>>

GO TO 2.

NO>>

Repair or replace the error-detected parts.

CHECK POWER ON SIGNAL CIRCUIT

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the voltage between electric shift control module harness connector and ground.

    +-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    M202 9 Ground Power switch: ON 9 – 16 V
    Power switch: OFF Approx. 0 V

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

GO TO 4.

CHECK ELECTRIC SHIFT CONTROL MODULE GROUND CIRCUIT

  1. Power switch OFF.

  2. Check continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 3 Ground Existed
    4
    6
    M203 25

Is the inspection result normal?

YES>>

Replace the electric shift control module. Refer to ELECTRIC SHIFT CONTROL MODULE : Removal & Installation.

NO>>

Repair or replace the error-detected parts.

DETECT MALFUNCTIONING ITEMS

Check the following items:

  • Harness for short or open between electric shift control module harness connector terminal 9 and fuse block (J/B) harness connector terminal 91

  • 10A fuse (#3)

Is the inspection result normal?

YES>>

GO TO 5.

NO>>

Repair or replace the error-detected parts.

PERFORM SELF-DIAGNOSIS

With CONSULT

  1. Power switch ON.

  2. Press the P position switch to shift to the P position.

  3. Erase self-diagnostic result for “SHIFT”.

  4. Perform self-diagnosis with DTC "Confirmation Procedure" again. Refer to Confirmation Procedure.

Is “U18A2-86” detected?

YES>>

Refer to Trouble Diagnosis Flow Chart.

NO>>

INSPECTION END

U215b-87 Can Comm Circuit Nissan Ariya 2023

DTC Description

DTC DETECTION LOGIC

DTCCONSULT screen termsDTC detection condition
U215B 87 CAN communication error (IPDM E/R) Diagnosis condition Power switch ON
Signal (terminal) CAN communication
Threshold Electric shift control module cannot transmit or receive CAN communication signals from IPDM E/R.
Diagnosis delay time 2 seconds or more

POSSIBLE CAUSE

  • Harness or connectors

    (Open or short-circuit of the CAN communication line)

  • CAN bus of electric shift control module

  • IPDM E/R

  • Open of the power ON signal circuit of electric shift control module

FAIL-SAFE

No impact to vehicle behavior

Confirmation Procedure

PRECONDITIONING

If another DTC “Confirmation Procedure” was performed immediately before this task, make sure to OFF the power switch, exit the Nissan Ariya vehicle and close all doors (including the back door), and wait for at least 65 seconds until the combination meter OFF before starting the next test.

>>

GO TO 2.

CHECK FOR DTC DETECTION

With CONSULT

  1. Set the power switch to ON and wait at least 5 seconds.

  2. Perform self-diagnosis for “SHIFT”.

    • If more than one DTC is detected, also perform diagnosis based on the DTC Inspection Priority Chart (Refer to DTC Inspection Priority Chart.).

Is "U215B-87" detected?

YES>>

Refer to DTC Diagnosis Procedure.

NO-1>>

To check malfunction symptom before repair: Refer to Intermittent Incident.

NO-2>>

Confirmation after repair: INSPECTION END

DTC Diagnosis Procedure

CHECK POWER ON SIGNAL CIRCUIT

  1. Power switch OFF.

  2. Disconnect electric shift control module harness connector.

  3. Check the voltage between electric shift control module harness connector and ground.

    +-ConditionVoltage
    Electric shift control module
    ConnectorTerminal
    M202 9 Ground Power switch: ON 9 – 16 V
    Power switch: OFF Approx. 0 V

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

GO TO 2.

DETECT MALFUNCTIONING ITEMS

Check the following items:

  • Harness for short or open between electric shift control module harness connector terminal 9 and fuse block (J/B) harness connector terminal 91

  • 10A fuse (#3)

Is the inspection result normal?

YES>>

GO TO 3.

NO>>

Repair or replace the error-detected parts.

CHECK ELECTRIC SHIFT CONTROL MODULE GROUND CIRCUIT

  1. Power switch OFF.

  2. Check continuity between electric shift control module harness connector and ground.

    Electric shift control module―Continuity
    ConnectorTerminal
    M202 3 Ground Existed
    4
    6
    M203 25

Is the inspection result normal?

YES>>

Refer to Trouble Diagnosis Flow Chart.

NO>>

Repair or replace the error-detected parts.