Evaporator Pressure Regulator
Removal
REMOVAL
COMPONENTS (REMOVAL)
Procedure | Part Name Code | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|---|
1 |
RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM |
- |
- |
- |
|
2 |
PRESSURE REGULATOR SUB-ASSEMBLY |
88503B |
- |
- |
|
*1 |
NO. 1 SUCTION TUBE |
*2 |
AIR CONDITIONING TUBE ASSEMBLY |
● |
Non-reusable part |
- |
- |
PROCEDURE
1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM
(a) for HFC-134a (R134a):
Click here ![]()
(b) for HFO-1234yf (R1234yf):
Click here ![]()
2. REMOVE PRESSURE REGULATOR SUB-ASSEMBLY

(1) Remove the 2 bolts and pressure regulator sub-assembly.
(2) Remove the O-ring from the No. 1 suction tube.
NOTICE:
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
(3) Remove the O-ring from the air conditioning tube assembly.
NOTICE:
Seal the openings of the disconnected parts using vinyl tape to prevent entry of moisture and foreign matter.
Installation
INSTALLATION
COMPONENTS (INSTALLATION)
Procedure | Part Name Code | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|---|
1 |
PRESSURE REGULATOR SUB-ASSEMBLY |
88503B |
- |
- |
|
2 |
CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT |
- |
- |
- |
|
3 |
WARM UP COMPRESSOR |
- |
- |
- |
|
4 |
INSPECT FOR REFRIGERANT LEAK |
- |
- |
- |
|
*1 |
NO. 1 SUCTION TUBE |
*2 |
AIR CONDITIONING TUBE ASSEMBLY |
![]() |
N*m (kgf*cm, ft.*lbf): Specified torque |
● |
Non-reusable part |
![]() |
Compressor oil ND-OIL 11 or equivalent |
- |
- |
PROCEDURE
1. INSTALL PRESSURE REGULATOR SUB-ASSEMBLY

*a |
Reference Point |
- |
- |
(1) Remove the vinyl tape from the air conditioning tube assembly and pressure regulator sub-assembly, and sufficiently apply compressor oil to a new O-ring and the fitting surface of the air conditioning tube assembly.
Compressor Oil:
ND-OIL 11 or equivalent
(2) Install the O-ring to the air conditioning tube assembly.
NOTICE:
Keep the O-ring and O-ring fitting surface free from foreign matter.
(3) Remove the vinyl tape from the No. 1 suction tube and pressure regulator sub-assembly, and sufficiently apply compressor oil to a new O-ring and the fitting surface of the No. 1 suction tube.
Compressor Oil:
ND-OIL 11 or equivalent
(4) Install the O-ring to the No. 1 suction tube.
NOTICE:
Keep the O-ring and O-ring fitting surface free from foreign matter.
(5) Connect the No. 1 suction tube and air conditioning tube assembly and pressure regulator sub-assembly as shown in the illustration.
NOTICE:
Install the pressure regulator sub-assembly with the arrow facing front.
(6) Install the pressure regulator sub-assembly with the 2 bolts as shown in the illustration.
Torque:
9,8 N·m {100 kgf·cm, 87 in·lbf}
2. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT
(a) for HFC-134a (R134a):
Click here ![]()
(b) for HFO-1234yf (R1234yf):
Click here ![]()
3. WARM UP COMPRESSOR
(a) for HFC-134a (R134a):
Click here ![]()
(b) for HFO-1234yf (R1234yf):
Click here ![]()
4. INSPECT FOR REFRIGERANT LEAK
(a) for HFC-134a (R134a):
Click here ![]()
(b) for HFO-1234yf (R1234yf):
Click here ![]()