Rain Sensor
On-vehicle Inspection
ON-VEHICLE INSPECTION
PROCEDURE
1. INSPECT RAIN SENSOR
Pre-procedure1
(a) Disconnect the rain sensor connector.
Procedure1
(b) Measure the voltage according to the value(s) in the table below. Standard Voltage:
|
|
(c) Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection | Condition | Specified Condition | Result |
|---|---|---|---|
U4-2(ES) - Body ground |
Always |
Below 1 Ω |
Ω |
Post-procedure1
(d) Reconnect the rain sensor connector. |
|
Procedure2
(e) Connect an oscilloscope to the rain sensor connector.
OK:
Tester Connection | Condition | Specified Condition |
|---|---|---|
U4-3(MPX) - U4-2(ES) |
Ignition switch ON Front wiper switch Auto |
Pulse generation |
HINT:
If the result is not as specified, replace the rain sensor.
Installation
INSTALLATION
COMPONENTS (INSTALLATION)
Procedure | Part Name Code | ![]() | ![]() | ![]() |
|
|---|---|---|---|---|---|
1 |
RAIN SENSOR TAPE |
89944 |
- |
- |
|
2 |
RAIN SENSOR |
89941 |
- |
- |
|
3 |
RAIN SENSOR COVER |
89943 |
- |
- |
- |
PROCEDURE
1. INSTALL RAIN SENSOR TAPE
HINT:
- Only perform this procedure when replacing the rain sensor tape.
- The rain sensor tape is reusable. Only replace the tape if it is damaged or contaminated with foreign matter.

(1) Remove the rain sensor tape.
(2) Clean the rain sensor sensing portion with a piece of cloth.
(3) Peel off the smaller release sheet, and then attach the new rain sensor tape to the rain sensor sensing portion as shown in the illustration.
HINT:
Use your fingers to push out any air bubbles from under the tape.
Standard ClearanceArea | Measurement | Area | Measurement |
|---|---|---|---|
A |
21.8 mm (0.858 in.) |
B |
7.25 mm (0.285 in.) |
2. INSTALL RAIN SENSOR
![]() |
NOTICE:
|

*a |
Stopper |
- |
- |
![]() |
Push |
![]() |
Install in this Direction |
(1) Clean the windshield glass with a piece of cloth.
(2) When installing a new rain sensor or when the rain sensor tape has been replaced:
1. Peel off the release sheet.
HINT:
Do not touch the silicone surface.
(3) Gradually attach the rain sensor to the windshield glass surface in the direction indicated by the arrow shown in the illustration to prevent air bubbles from forming between them.
(4) Push in the stopper to install the rain sensor as shown in the illustration.
(5) Connect the connector.
3. INSTALL RAIN SENSOR COVER