B terminal circuit
Description
Terminal "B" is constantly supplied with battery power.
Diagnosis Procedure
Regarding Wiring Diagram information, refer to STR, "Wiring Diagram - With Intelligent Key System" or STR, "Wiring Diagram - Without Intelligent Key System".
CAUTION: Perform diagnosis under the condition that the engine cannot start by the following procedure.
- Remove fuel pump fuse.
- Crank or start the engine (where possible) until the fuel pressure is released.
1.CHECK "B" TERMINAL CIRCUIT
- Turn ignition switch OFF.
- Check that starter motor B" terminal connection is clean and tight.
- Check voltage between starter motor connector F27 and ground.

Is the inspection result normal?
YES >> GO TO 2.
NO >> Check harness between battery and starter motor for open circuit.
2.CHECK BATTERY CABLE CONNECTION STATUS (VOLTAGE DROP TEST)
- Shift selector lever to P (Park) or N (Neutral) position.
- Check voltage between battery positive terminal and starter motor B terminal.

Is the inspection result normal?
YES >> GO TO 3.
NO >> Check harness between the battery and starter motor for continuity.
3.CHECK GROUND CIRCUIT STATUS (VOLTAGE DROP TEST)
- Shift selector lever to P (Park) or N (Neutral) position.
- Check voltage between starter motor case and battery negative terminal.

Is the inspection result normal?
YES >> "B" terminal circuit is OK. Further inspection is necessary. Refer to STR, "Work Flow (With GR-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)".
NO >> Check the starter motor case to engine mounting for high resistance.