S connector circuit
Description
The starter motor magnetic switch is supplied with power when the ignition switch is turned to the START position while the selector lever is in the P (Park) or N (Neutral) position.
Diagnosis Procedure
Regarding Wiring Diagram information, refer to STR, "Wiring Diagram - With Intelligent Key System" or STR, "Wiring Diagram - Without Intelligent Key System".
CAUTION: Perform diagnosis under the condition that engine cannot start by the following procedure.
- Remove fuel pump fuse.
- Crank or start the engine (where possible) until the fuel pressure is released.
1.CHECK "S" CONNECTOR CIRCUIT
- Turn ignition switch OFF.
- Disconnect starter motor connector.
- Shift selector lever to "P" (Park) or "N" (Neutral) position.
- Check voltage between starter motor harness connector F28 and ground.

Is the inspection result normal?
YES >> "S" circuit is OK. Further inspection is necessary. Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)".
NO >> GO TO 2.
2.CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
- Disconnect IPDM E/R connector.
- Check continuity between starter motor harness connector F28 and the IPDM E/R harness connector E43.

- Check continuity between starter motor connector F28 terminal S and ground.

Is the inspection result normal?
YES >> Further inspection is necessary. Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)".
NO >> Repair or replace the harness or connectors.
STARTING SYSTEM
Symptom Table
| Symptom | Reference |
| No normal cranking | Refer to STR, "Work Flow (With GR8-1200 NI)" or STR, "Work Flow (Without GR8-1200 NI)". |
| Starter motor does not rotate |