Horn function
Description
Perform answer-back for each operation with horn.
Component Function Check
1.CHECK FUNCTION
- Select HORN in "ACTIVE TEST" mode with CONSULT.
- Check the horn operation.

Is the operation normal?
YES >> Inspection End.
NO >> Refer to DLK "Diagnosis Procedure".
Diagnosis Procedure
Regarding Wiring Diagram information, refer to DLK "Wiring Diagram".
1.CHECK HORN FUNCTION
Check horn function with horn switch.
Does the horn sound?
YES >> GO TO 2
NO >> Refer to HRN "Wiring Diagram".
2.CHECK HORN RELAY POWER SUPPLY
- Turn ignition switch ON.
- Perform "ACTIVE TEST" ("HORN") with CONSULT.
- Using an oscilloscope or analog voltmeter to check voltage between IPDM E/R connector and ground.

Is the inspection result normal?
YES >> Repair or replace open harness between IPDM E/R and horn relay.
NO >> GO TO 3
3.CHECK HORN RELAY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R and horn relay connector.
- Check continuity between IPDM E/R harness connector and horn relay harness connector.

- Check continuity between IPDM E/R harness connector and ground.

Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4.CHECK INTERMITTENT INCIDENT
Refer to GI "Intermittent Incident".
Is the inspection result normal?
YES >> Replace IPDM E/R. Refer to PCS "Removal and Installation".
NO >> Repair or replace the malfunctioning part.