O/D OFF indicator lamp
Component Function Check
1.CHECK O/D OFF INDICATOR LAMP FUNCTION
Check O/D OFF indicator lamp turns ON for approx. 2 seconds when ignition switch turns ON.
Is the inspection results normal?
YES >> INSPECTION END
NO >> Go to TM "Diagnosis Procedure".
Diagnosis Procedure
1.CHECK DTC (TCM)
With CONSULT
- Turn ignition switch ON.
- Check "Self Diagnostic Results" in "TRANSMISSION".
Is any DTC detected?
YES >> Check DTC detected item. Refer to TM "DTC Index".
NO >> GO TO 2.
2.CHECK DTC (COMBINATION METER)
With CONSULT
Check "Self Diagnostic Results" in "METER/M&A".
Is any DTC detected?
YES >> Check DTC detected item. Refer to MWI "DTC Index".
NO >> GO TO 3.
3.CHECK COMBINATION METER INPUT SIGNAL
With CONSULT
- Shift the selector lever to "D" position.
- Select "Data Monitor" in "METER/M&A".
- Select "O/D OFF IND".
- Check that "O/D OFF IND" turns ON/OFF when overdrive control switch is operated. Refer to MWI "Reference Value".
Is the inspection result normal?
YES >> Replace combination meter. Refer to MWI "Removal and Installation".
NO >> GO TO 4.
4.CHECK TCM INPUT/OUTPUT SIGNAL
With CONSULT
- Select "Data Monitor" in "TRANSMISSION".
- Select "OD CONT SW".
- Check that "OD CONT SW" turns ON/OFF when overdrive control switch is operated. Refer to TM-99, "Reference Value".
Is the inspection result normal?
YES >> Replace combination meter. Refer to MWI "Removal and Installation".
NO >> Check overdrive control switch. Refer to TM "Diagnosis Procedure".