Refrigerant pressure sensor
In this manual: Refrigerant pressure sensor
3steps
~18min
2/5difficulty
Done 0 of 3
Removal and Installation for Refrigerant Pressure Sensor
REMOVAL
CAUTION:
- Do not damage the condenser fins.
- Perform lubricant return operation before each refrigeration system disassembly. However, if a large amount of refrigerant or lubricant is detected, do not perform lubricant return operation.
Refer to HA "Perform Oil Return Operation".
- Move air guide aside.
- Disconnect the harness connector from the refrigerant pressure sensor.
- Remove the refrigerant pressure sensor (1) from the liquid tank on the condenser.

INSTALLATION
Installation is in the reverse order of removal.
CAUTION:
- Replace O-ring with new one. Then apply compressor oil to them when installing.
- Check for leakages when recharging refrigerant. Refer to HA "Leak Test".
Was this page helpful?