Component parts
In this manual: Component parts
~1min read
Component Parts Location

1. Condenser 2. Compressor 3. Refrigerant pressure sensor 4. Liquid tank 5. Evaporator 6. Expansion valve A. Built-in heater & cooling unit assembly
Component Description
| Component | Description |
| Evaporator | The mist form liquid refrigerant transforms to gas by evaporation by the air conveyed from blower motor. The air is cooled by the heat by evaporation. |
| Condenser | Cools refrigerant discharged from compressor, and transforms it to liquid refrigerant. |
| Compressor | Intakes, compresses, and discharges refrigerant, to circulate refrigerant inside the refrigerant cycle. |
| Refrigerant pressure sensor | Refer to HA "Removal and Installation". |
| Liquid tank | Eliminates foreign matter in refrigerant, and temporarily stores liquid refrigerant. |
| Expansion valve | Transforms high-pressure liquid refrigerant to mist form low-pressure liquid refrigerant by drawing function. |
Was this page helpful?