Main power supply and ground circuit
Diagnosis Procedure
1.CHECK TCM POWER CIRCUIT 1
- Turn the ignition switch OFF.
- Disconnect the TCM connector.
- Check the voltage between the TCM harness connector terminals and ground.

Is the inspection result normal?
YES >> GO TO 2.
NO >> GO TO 4.
2.CHECK TCM POWER CIRCUIT 2
Check the voltage between the TCM harness connector terminals and ground. 
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 5.
3.CHECK TCM GROUND CIRCUIT
Check the continuity between TCM harness connector terminals and ground. 
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
4.DETECT MALFUNCTION ITEMS (PART 1)
Check the following items:
- Open or short circuit of the harness between battery positive terminal and TCM connectors terminal 45.
- 10A fuse [No.25, fuse block (J/B)]. Refer to PG "Terminal Arrangement".
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.
5.DETECT MALFUNCTION ITEMS (PART 2)
Check the following items:
- Open or short circuit of the harness between IPDM E/R harness connector terminal 21 and TCM connector terminals 47, 48.
- Harness open circuit or short circuit between the ignition switch and IPDM E/R. Refer to PG, "Wiring Diagram - Ignition Power Supply -".
- 10A fuse [No.49, IPDM E/R]. Refer to PG-62, "IPDM E/R Terminal Arrangement".
- IPDM E/R
Is the inspection result normal?
YES >> Check intermittent incident. Refer to GI, "Intermittent Incident".
NO >> Repair or replace the malfunctioning parts.